10-11
■
Cleaning air cleaner primary element
1. Remove the air cleaner cover and primary
element.
2. Remove the sponge material from its
frame.
3. Wash the sponge material gently but
thoroughly in solvent.
4. Squeeze the excess solvent out of the
sponge material and let it dry.
5. Inspect the sponge material and replace it
if damaged.
6. Thoroughly apply foam air filter oil or other
quality liquid foam air filter oil (not spray
type) to the sponge material.
7. Re-install the air filter element.
8. Install the air filter case cover and be sure
the crankcase breather hose is connected.
①
Air filter element
①
Air filter element
②
Locating pad
①
Holder
(×6)
②
Air filter case cover
IMPORTANT
The air cleaner uses a dry element never
apply oil.
Do not run the engine with filter element
removed.
Be sure to refit the cower with the arrow
(on the rear of cower ) upright if the cover
is improperly fitted the evacuator valve will
not function and dust will adhere to the
element.
◆
Evacuator Valve
Open the air cleaner cover once a week under
ordinary conditions –or daily when used in a
dusty place-to get rid of large particles of dust
and dirt.