![HISTREAM HD IP Speed Dome Camera User Manual Download Page 36](http://html1.mh-extra.com/html/histream/hd-ip-speed-dome-camera/hd-ip-speed-dome-camera_user-manual_2139301036.webp)
IP Camera User’s Manual
36/66
each picture is 1 second.
[Record]
: When alarm is triggered, the device SD card will be driven to record images. The
record files can be saved via E-mail sending or FTP uploading.
After setting all the parameters, click
[save]
to make the parameters valid.
Notice
:
:
:
:
Record file packet time equals duration of alarm add the
recocd time setted in
[Linkage recording]
.
5.2.5.3 Failure Setting
See Figure 37 for the interface of “Failure Setting”:
Figure 37
Set network failure alarm parameters here: detection on/off, linkage alarm, alarm output
duration, E-mail sending when alarm has been triggered, linkage snapping/recording, etc.
[Enable detect]
: Enable or disable network failure alarm detection.
[Sensor type]
: NO and NC mode.
[Alarm output]
: Enable or disable linkage alarm output
[Alarm output duration]
:
Set the duration of the linkage alarm output after being triggered (in
seconds), the range of the duration is 0~86400s.0 means that there is no limit for alarm
output.