Service Manual
DS 350 GM
Rev A 05/01/01 // SB
190113_A
22
Measure length signal of amplified output on analog input module between test
point MP0 and X1:3. The measurement should be between 0.5-4.5v.
0.5v(500mv) with the boom fully retracted and the length potentiometer set fully
counter-clockwise to a soft stop OR 4.5v with the length potentiometer turned
completely clockwise 10 turns to the soft stop.
Refer to Drawing 9 in Section 4.
Analog Input board defective.
Replace analog input board.
Refer to Drawing 4 in Section 4 and Replacement
Procedure 3 steps 4,11, & 12 in Section 4.
Correct?
PREVIOUS PAGE
END
NO
YES