Service Manual
DS 350 GM
Rev A 05/01/01 // SB
190113_A
12
ERRO
R
CODE
ERROR
CAUSE
ACTION
E95
Error in the crane data
EPROM
a.) Data EPROM defective
b.) Position of jumper for the
selection of the type of
EPROM is wrong
c.) Electronics component
on the main board defective.
a.) Replace data EPROM
b.) Check the jumper position
c.) Replace CPU module. Refer
to Drawing 4 and Procedure 3
Steps 1-3, 13,14
E96
Error in the internal
RAM of the CPU of the
console
CPU or main board of the
console defective
Replace CPU module. Refer to
Drawing 4 and Procedure 3
Steps 1-3, 13,14
E97
Error in the external
RAM of the CPU of the
console
a.) External RAM of the
console defective
b.) Electronic component on
the main board defective.
a.) Replace console main board
b.) Replace console main board
Refer to Drawing 5.
E98
Wrong jumper position
in the console
a.) The jumper position BR
9/BR 10 in the console does
not correspond to the actual
type of central unit.
b.) Electronic component on
the main board defective.
a.) Check the jumper position
b.) Replace console main board
Refer to Drawing 5.
EAB
Short circuit in the A2B
switch circuit
Short circuit in the A2B switch
Short circuit in the cable to
the A2B switch
Electronic component on the
analog input module
defective.
Refer to Section 3.6.
Replace A2B switch
Replace cable to the A2B switch
Check analog input module.
Replace if necessary., Refer to
Drawing 4 and Procedure 3
Steps 1,2,4, 11,12.
Note:
If an error message is displayed which is not contained in above list, please contact the PAT service
department.