Hirschmann BAT-R User Manual Download Page 2

The naming of copyrighted trademarks in this manual, even when not specially indicated, should 
not be taken to mean that these names may be considered as free in the sense of the trademark 
and tradename protection law and hence that they may be freely used by anyone.

© 2017 Hirschmann Automation and Control GmbH

Manuals and software are protected by copyright. All rights reserved. The copying, reproduction, 
translation, conversion into any electronic medium or machine scannable form is not permitted, 
either in whole or in part. An exception is the preparation of a backup copy of the software for 
your own use.

The performance features described here are binding only if they have been expressly agreed 
when the contract was made. This document was produced by Hirschmann Automation and 
Control GmbH according to the best of the company's knowledge. Hirschmann reserves the right 
to change the contents of this document without prior notice. Hirschmann can give no guarantee 
in respect of the correctness or accuracy of the information in this document.

Hirschmann can accept no responsibility for damages, resulting from the use of the network 
components or the associated operating software. In addition, we refer to the conditions of use 
specified in the license contract.

You can get the latest version of this manual on the Internet at the Hirschmann product site 
(www.hirschmann.com).

Hirschmann Automation and Control GmbH
Stuttgarter Str. 45-51
72654 Neckartenzlingen
Germany

Installation BAT-R

 20.03.2017

Summary of Contents for BAT-R

Page 1: ...Installation BAT R Release 09 03 2017 Technical Support https hirschmann support belden eu com User Manual Installation Open Dual Band Industrial Access Point Client Access Bridge OpenBAT Family BAT R...

Page 2: ...binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the company s knowledge Hirsch...

Page 3: ...gabit combo port 30 1 5 2 10 100 1000 Mbit s twisted pair connection optional 31 1 5 3 Pin assignments 31 1 6 Connections for antennas 33 1 7 Display elements 33 1 7 1 Meaning of the LEDs 33 1 7 2 Dev...

Page 4: ...combo port 46 2 7 2 10 100 1000 Mbit s twisted pair connection optional 46 3 Making basic settings 47 4 Configuring the transmit power 48 5 Maintenance and service 50 6 Disassembly 51 6 1 Removing th...

Page 5: ...allation BAT R Release 09 03 2017 5 7 8 Network range 63 7 9 Power consumption power output 64 8 Scope of delivery order numbers and accessories 65 9 Underlying technical standards 67 A Further suppor...

Page 6: ...r malfunction of the device turn off the supply voltage and return the device to the plant for inspection Certified usage Use the product only for the application cases described in the Hirschmann pro...

Page 7: ...ical data on page 52 For use in UL60950 1 conditions Install the device in a fire enclosure Device casing Only technicians authorized by the manufacturer are permitted to open the casing Never insert...

Page 8: ...d to the ground connector on the front panel as a conductor Lightning protection Refer to the information in the WLAN Outdoor Guide on lightening and overvoltage protector Install over voltage protect...

Page 9: ...h the requirements as per Class 2 Alternative 3 All of the following requirements are complied with The power supply complies with the requirements for a safety extra low voltage SELV as per IEC EN 60...

Page 10: ...ng label may be operated When operating the BAT R types with characteristic value G for approvals 1 ATEX zone 2 the following applies Never use the supply voltage with characteristic value K in Ex zon...

Page 11: ...otection of at least IP54 according to EN 60529 taking into account the environmental conditions under which the equipment will be used Relevant for use in explosion hazard areas Hazardous Locations C...

Page 12: ...C 265 V AC or 48 V DC 320 V DC The earth conductor must be at least the same wire size mm or AWG as the supply conductors Relay contacts Equipment with nonincendive eld wiring parameters Polarity is n...

Page 13: ...ITY FOR HAZAR DOUS LOCATIONS OR EXPLOSIVE ATMOSPHERES WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS Notes The nonincen...

Page 14: ...ropean directive s 2011 65 EU RoHS Directive of the European Parliament and of the Council on the restriction of the use of certain hazardous substances in electrical and electronic equipment 1999 5 E...

Page 15: ...n conditions In Germany the usage of this band is restricted to commercial public telecommunication services BFWA Broadband Fixed Wireless Access Registration at the Federal Network Agency is required...

Page 16: ...try approvals which are labeled as follows Contains Transmitter Module FCC ID U99EWLAN1 IC 4019A EWLAN1 This equipment complies with FCC and IC RSS 102 radiation exposure limits set forth for an uncon...

Page 17: ...dBi antenna between the radiator and your body The antenna used for this transmitter must not be co located with any other transmitters within a host device except in accordance with FCC multi transmi...

Page 18: ...in this way exclusively Differing connection configurations are illegal Note for the use in the Japan This note applies to BAT R variants with the characteristic value JP Japan for country approvals...

Page 19: ...he 5 GHz band is restricted to indoor usage Recycling note After usage this device must be disposed of properly as electronic waste in accordance with the current disposal regulations of your county s...

Page 20: ...n BAT R Release 09 03 2017 About this manual The Installation user manual contains a device description safety instructions a description of the display and the other information that you need to inst...

Page 21: ...Installation BAT R Release 09 03 2017 21 Key The symbols used in this manual have the following meanings Listing Work step Subheading...

Page 22: ...th of up to 450 Mbit s The devices support MIMO Multiple Input Multiple Output and Multipath The bandwidth is increased by using the multipath transmission by means of reflections Each WLAN module has...

Page 23: ...download these manuals as PDF files from the Internet on the Hirschmann product pages www hirschmann com The Industrial HiVision Network Management software provides you with additional options for sm...

Page 24: ...ule 9 Slot 2 W WLAN module 9 Not assembled 10 Slot 3 9 Not assembled 11 Access point or client A Access Point C Client 12 Supply voltage 1 C Rated voltage range DC 24 V 48 V K Rated voltage range DC 6...

Page 25: ...port 19 20 Ethernet port 2 T1 RJ45 socket for 10 100 1000 Mbit s Twisted Pair connections 99 Not present 21 Temperature range E Extended with Conformal Coating 40 F 158 F 40 C 70 C K Extended with Con...

Page 26: ...ly The area is accessible without tools The person responsible for the area has provided access for the operator intentionally The operator knows of the access possibilities regardless of whether they...

Page 27: ...characteristic value K 1 WLAN module 1 3 reverse SMA connection 2 Optional WLAN module 2 3 reverse SMA connection 3 LED display elements for device status 4 Ethernet port 1 Combo port you can use the...

Page 28: ...the characteristic value C 2 pin terminal block Supply voltage with the characteristic value K 3 pin terminal block 5b Connection for signal contact 1 5c Optional Power supply connection 2 Supply volt...

Page 29: ...as the PoE power supply voltage The PoE power supply means that no separate power supply is required for your device For further information see 10 100 1000 Mbit s PoE PD port on page 46 1 4 4 Supply...

Page 30: ...standard This port supports Autocrossing if autonegotiation is activated Autonegotiation Autopolarity 10 Mbit s half duplex mode 10 Mbit s full duplex mode 100 Mbit s half duplex mode 100 Mbit s full...

Page 31: ...t s twisted pair port on page 30 1 5 3 Pin assignments RJ45 Pin 10 100 Mbit s 1000 Mbit s PoE MDI mode 1 TX BI_DA Positive VPSE a a Phantom supply 2 TX BI_DA Positive VPSE a 3 RX BI_DB Negative VPSE a...

Page 32: ...R Release 09 03 2017 M12 8 pin X coded Pin 10 100 Mbit s 1000 Mbit s PoE 1 RX BI_DB Negative VPSE 2 RX BI_DB Negative VPSE 3 TX BI_DA Positive VPSE 4 TX BI_DA Positive VPSE 5 BI_DC 6 BI_DC 7 BI_DD 8 B...

Page 33: ...ng of the LEDs The following terms describe the behavior of the LEDs Regular flashing the LED switches on and off at regular intervals in the specified sequence e g red off Brief flashing the LED ligh...

Page 34: ...ling is performed by P1 red green flashing quickly Unprotected configuration as no password or the default password is set a red off flashing quickly Hardware error detected b red green Running light...

Page 35: ...utomate the configuration of a point to point WLAN line by connecting two devices directly via the serial interface You will find more information here User Manual Configuration Guide table 6 on page...

Page 36: ...nterface has the following properties Supports the USB master mode Supports USB 1 1 data rate max 12 MBit s Pins of the M12 socket on the device Pin assignment for the connection with a cable Pins of...

Page 37: ...ltage with the characteristic value C K or W have a signal contact exclusively You have the option of setting the signal contact manually using the device management 1 10 Reset button The device has a...

Page 38: ...device Checking the package contents Installing and grounding the device Installing an SFP transceiver optional Installing the antennas Connecting the terminal blocks optional Operating the device Co...

Page 39: ...DIN rail Snap in the device by releasing the rail lock slide WARNING FIRE HAZARD For use in UL60950 1 conditions Install the device in a fire enclosure Relevant for Europe Install the device in a fir...

Page 40: ...or protective ground The device variants featuring supply voltage with characteristic value W have a connection for functional ground Ground the device via the ground screw The ground screw is surroun...

Page 41: ...from one WLAN module being received by the other WLAN module Relevant for use of BAT ANT N MiMo 18N IP65 with FCC and approval 2 characteristic value H The devices are labeled as follows FCC ID U99EW...

Page 42: ...tion terminals for electric conductors Do not touch the connection terminals Start connecting the electrical wires only if all the above safety requirements are fulfilled See Requirements for connecti...

Page 43: ...n a switch cabinet or in an operating site with restricted access to which maintenance staff have exclusive access Failure to follow these instructions can result in death serious injury or equipment...

Page 44: ...th screw locking For every supply voltage to be connected perform the following steps Remove the power connector from the device Connect the wires according to the pin assignment on the device with th...

Page 45: ...k or a twisted pair cable Power over Ethernet you start the operation of the device 2 6 1 Connecting the power supply through a terminal block Relevant for North America The torque for tightening the...

Page 46: ...ort on page 30 Connect the data cables according to your requirements 1000 Mbit s F O port For further information see 1000 Mbit s F O port on page 31 Make sure that you connect LH ports exclusively w...

Page 47: ...figuring IP addresses Entry via V 24 connection Entry via the HiDiscovery protocol in the applications HiDiscovery or Industrial HiVision Configuration via BOOTP Configuration via DHCP Option 82 AutoC...

Page 48: ...from the Hirschmann product pages www hirschmann com In the graphical user interface proceed as follows In the menu tree open the Configuration Wireless LAN General dialog In the General tab specify i...

Page 49: ...BAT R Release 09 03 2017 49 Subtract the cable and installed over voltage protector attenuation from the antenna gain Enter the calculated value in the Antenna gain field To save the value click the...

Page 50: ...itching function depending on the frequency of the switching operations Hirschmann is continually working on improving and developing their software Check regularly whether there is an updated version...

Page 51: ...antennas Disconnect the grounding Insert a screwdriver horizontally below the housing into the locking gate Pull the locking gate down without tilting the screwdriver Lift the bottom of the device aw...

Page 52: ...k Power loss buffer 10 ms at 20 4 V DC Overload current protection at input Non replaceable fuse Back up fuse for each voltage input when supply is via 2 inputs Nominal rating Characteristic Max 1 5 A...

Page 53: ...device Top and bottom device side 3 94 in 10 cm Left and right device side 0 79 in 2 cm Ambient air temperaturec Devices with operating temperature characteristic value S standard 32 F 140 F 0 C 60 C...

Page 54: ...tion IP20 a When supplied with 24 V possible as alternative to back up fuse Supply voltage based on NEC Class 2 or EN 60950 1 Limited Power Source b As an alternative to the back up fuse is possible S...

Page 55: ...3 2017 55 Figure 6 Dimensions of device variants featuring supply voltage with the characteristic value C or K See table 3 on page 24 Note figure without connections 145 mm 150 6 mm 120 8 mm 136 4 mm...

Page 56: ...A1 TKIPd For more information see the HiLCOS data sheet a With encryptions of the type TKIP and WEP the device falls back on IEEE 802 11b g or IEEE 802 11a b With encryptions of the type TKIP and WEP...

Page 57: ...nsmit power Typical receive sensitivity 6 Mbps 16 dBm 93 dBm 9 Mbps 16 dBm 93 dBm 12 Mbps 16 dBm 93 dBm 18 Mbps 16 dBm 91 dBm 24 Mbps 16 dBm 88 dBm 36 Mbps 15 dBm 84 dBm 48 Mbps 13 dBm 80 dBm 54 Mbps...

Page 58: ...Bm MCS15 15 dBm 72 dBm MCS16 23 dBm 87 dBm MCS17 23 dBm 90 dBm MCS18 23 dBm 86 dBm MCS19 23 dBm 82 dBm MCS20 16 dBm 79 dBm MCS21 17 dBm 75 dBm MCS22 17 dBm 73 dBm MCS23 16 dBm 72 dBm IEEE 802 11n Band...

Page 59: ...omatically reduces the data rate and transmit power downward This is due to national standards MCS6 14 dBm 75 dBm MCS7 14 dBm 73 dBm MCS8 20 dBm 92 dBm MCS9 20 dBm 91 dBm MCS10 19 dBm 89 dBm MCS11 20...

Page 60: ...it power Typical receiving sensitivity 6Mbps 22 dBm 94 dBm 9Mbps 22 dBm 94 dBm 12Mbps 22 dBm 90 dBm 18Mbps 22 dBm 89 dBm 24Mbps 22 dBm 85 dBm 36Mbps 21 dBm 82 dBm 48Mbps 20 dBm 78 dBm 54Mbps 19 dBm 77...

Page 61: ...7 dBm 75 dBm MCS22 17 dBm 73 dBm MCS23 16 dBm 72 dBm IEEE 802 11n Bandwidth 5 180 GHz to 5 825 GHz Coding Typical transmit power Typical receiving sensitivity MCS0 11 dBm 92 dBm MCS1 11 dBm 91 dBm MCS...

Page 62: ...omagnetic field 80 MHz 1000 MHz 20 V m 1400 MHz 2700 MHz 10 V m EN 61000 4 4 Fast transients burst test level 4 DC power line 4 kV AC Power Line 4 kV Data line 4 kV EN 61000 4 5 Voltage surges DC powe...

Page 63: ...culations SX LC MM 850 nm 50 125 m 0 7 5 dB 0 550 m 3 0 dB km 400 MHz km SX LC MM 850 nm 62 5 125 m 0 7 5 dB 0 275 m 3 2 dB km 200 MHz km LX LC MM 1310 nm c c With F O adapter compliant with IEEE 802...

Page 64: ...R Release 09 03 2017 7 9 Power consumption power output Conditions Maximum power consumption Power output When equipped with 1 WLAN module 12 95 W 44 19 BTU IT h When equipped with 2 WLAN modules 17...

Page 65: ...g supply voltage with the characteristic value C or W 2 premounted 3 pin terminal block for the supply voltage only for device variants featuring supply voltage with the characteristic value K 2 premo...

Page 66: ...terminating resistors for closing unused antenna connections N 10 pieces 942 117 001 Antenna cable BAT CLB 2 N m f 943 903 514 AutoConfiguration Adapter ACA21 USB EEC 943 271 003 For device variants f...

Page 67: ...f materials and components EN 50155 Railway applications Electronic equipment used on rolling stock EN 55022 Information technology equipment Radio disturbance characteristics Limits and methods of me...

Page 68: ...Release 09 03 2017 The device has an approval based on a specific standard only if the approval indicator appears on the device casing The device generally fulfills the technical standards named in t...

Page 69: ...Competence Center is ahead of its competitors on three counts with its complete range of innovative services Consulting incorporates comprehensive technical advice from system evaluation through netwo...

Page 70: ......