![Hirschmann 943 893-321 Manual Download Page 34](http://html1.mh-extra.com/html/hirschmann/943-893-321/943-893-321_manual_2138076034.webp)
8 Technical Data
32
Version 1.0 03/06
Repeater
OZD 485 G12 BAS
Order No.
943 893-321
Climatic ambient conditions
Ambient temperature
– 25 °C to + 70 °C (IEC 60068-2-1, IEC 60068-2-2)
Storage temperature
– 25 °C to + 80 °C (IEC 60068-2-14)
Relative humidity
< 95 %, non-condensing (IEC 60068-2-30)
Air pressure
during operation: up to 2000 m (795 hPa)
transport and storage: up to 3000 m (700 hPa)
Contamination level
2
Mechanical ambient conditions
Vibrations
3 to 9 Hz, 3.5 mm amplitude (IEC 61131-2);
9 to 150 Hz, 1 g acceleration (IEC 61131-2)
Shock
15 g, 11 ms duration, 18 shocks (IEC 61131-2)
Protection class
IP 20
Weight
176 g
Dimensions (W x H x D, with connections)
35 x 156 x 114 mm
Housing material
Plastic PA6.6, aluminium