7.1 LED displays
27
7 Help with problems
Version 1.0 03/06
7 Help with problems
Fig. 16: LED indicators on the front panel
System
OZD 485 G12 BAS
DA/STAT
3
1
2
RT+
LED display
System
䡲
green
䡲
off
DA/STAT 1
䡲
yellow
䡲
off
DA/STAT 2
䡲
green
䡲
yellow
䡲
off
DA/STAT 3
䡲
green
䡲
yellow
䡲
off
Possible causes
– Repeater operating correctly
– Supply voltage interrupted
– Internal device error
– Data received at port 1
– No input signal at port 1
– Input signal at port 2 ok
– Optical data received at port 2
– No input signal at port 2
– Input signal at port 3 ok
– Optical data received at port 3
– No input signal at port 3