55
────────────────────────────────────────────────────
8.3 Command Reference
────────────────────────────────────────────────────
Syntax
:HARMonic:DIVider?
Response
syntax
:HARMONIC:DIVIDER
<1-255>
Example
Transmission
Response
":HARMonic:DIVider?"
":HARMONIC:DIVIDER 10"
Function
Obtains the frequency dividing ratio of
the external sync signal.
Syntax
:HARMonic:LPF
<NR1>
<NR1>= 0,1,2
0: None (no averaging)
1: Amplitude (Harmonicrms value)
2: Phase angle (Harmonic phase angle)
Example
"HARMonic:LPF 1"
Amplitude is selected to be averaged.
Function
According to the harmonic waveform
analysis results, selects an object to be
averaged.
Syntax
:HARMonic:LPF?
Response
syntax
:HARMONIC:LPF
<0/1/2>
Example
Transmission
Response
":HARMonic:LPF?"
":HARMONIC:LPF 1"
Amplitude has been selected as the
object to be averaged.
Function
Obtains the object selected to be
averaged.
Syntax
:HARMonic:PHASezero
Example
":HARMonic:PHASezero"
Function
When measuring with an external sync
signal, the phase angle of U1 is
normalized to zero degrees. Other
measurement values are adjusted relative
to the amount of U1 normalization.
Note
Power phase difference is not adjusted.
:HARMonic:DIVider?
Queries the external sync signal frequency dividing ratio.
:HARMonic:LPF
Averaging setting
:HARMonic:LPF?
Queries the average setting.
:HARMonic:PHASezero
Phase angle zero adjust of external sync signal