![Hiniker 8160 Operator'S Manual Download Page 42](http://html.mh-extra.com/html/hiniker/8160/8160_operators-manual_2136894042.webp)
40 Installation - Spray Control
Boom Valve Connections
The “Ball Valve” Cable is for connecting to three
three-wire ball valves. It has three 3-pin Weath-
erpack connectors for connecting to three mo-
torized ball valves. It also contains the 2-pin
connector for the Remote Run/Hold Switch or
sensor.
Refer to drawing 5933 for proper connections.
The control wire colors are Green (Left), Yellow
(Center), and Blue (Right). Power is removed
from these wires when the console is in the Hold
Mode. The Black/White wires are the grounds,
which are supplied through the console. The
Red/White wires are connected directly to the
battery through the console. The Red/White
wires will always have 12 volts on them to allow
the valves to close when the console is turned
off.
The Weatherpack connectors will plug directly
into 1AV-M valves from KZCO. Before making
connections, check the wiring on your particular
valve to see if it is wired the same. It may be
necessary to re-pin or replace the connector for
your type of motorized valve. The harness will
work with all 3-wire valves that require 12 volts
on the control wire to open the valve.
A boom valve pigtail kit is available for convert-
ing from the boom connector to individual wires.
This allows for a custom connection to other
type valves.
NOTE:
if using a swath control system refer to
the information on swath control in the appendix.
DWG. NO. 5933
Summary of Contents for 8160
Page 2: ......