The 8160 is constructed to allow for maximum
flexibility when changing between Spray and
NH3 applications. The console will be config
-
ured individually for each application Set-up. The
menu will allow you to easily access and change
the configuration of each Set-up without effect
-
ing the other. All calibration information and user
preference settings are stored separately for the
Spray and NH3 configurations.
IS THIS SPRAY
APPLICATION?
NO
GPA RATE 1 20.0
GPA RATE 210.0
LEFT BOOM 120”
CENTER BOOM 120”
RIGHT BOOM 120”
SERVO VALVE
RESPONSE = 6
FLOWMETER
PULSES/GAL = 72.0
DISTANCE CAL.#
PULSES/FT - 2.00
IS THIS AN INLINE
SYSTEM? Y
8160 MENU SYSTEM
MAIN MENU
IS THIS NH3
APPLICATION? Y
PPA RATE 1 180.0
PPA RATE 2 150.0
LEFT BOOM 510”
CENTER BOOM 0”
RIGHT BOOM 0”
SERVO VALVE
RESPONSE = 6
FLOWMETER
PULSES/LB = 16.9
DISTANCE CAL. #
PULSES/FT - 2.00
GO TO OPTIONS MENU? N
ENTER BASED ON
CURRENT OPERATING
MODE WHEN SET
WAS PRESSED
NO
8160 MENU SYSTEM
MAIN MENU
YES
YES
SPRAY
NH3
NO
NO
EXIT
EXIT
TO SPRAY
OPTIONS MENU
TO NH3
OPTIONS MENU
14 Operation
To enter the Main Menu press and hold the SET
key for 2 seconds.
Upon entering the main menu the current select-
ed mode will be displayed, either Spray or NH3.
To change to the other mode (Spray or NH3)
press the key to change the answer to NO
then press SET.
Navigating the Menu
Three keys are used to navigate the menu. They
are the SET, the key and key.
NOTE: Pressing any other key except SET,
, ,
will provide a shortcut out of the menu system.
The and keys are used to change a Value or
an Answer that is being displayed. The key will
increase a Value or change the answer to Yes
(Y). The key will decrease a Value or change
the answer to No (N). These keys are also used
to control the Servo Valve when in Manual.
The SET key is the same as the ENTER key on
a computer keyboard and performs the same
function. Pressing the SET key will cause the
console to accept whatever is currently being
displayed. This could be a Value, such as “LEFT
BOOM 120”, or the answer (Y or N) to a question
such as “GO TO OPTIONS MENU? “N“.
There are two types of menu items. The first are
items that require a “Value”. Examples are “GPA
RATE 1 20.0” or “FLOWMETER PULSES/GAL
= 72.0” Use the and keys to change the
“Value” then press the SET key to accept these
changes and proceed to the next menu item.
The second type of menu items are those that
require an “answer” to a question. An example
would be “IS THIS SPRAY APPLICATION? Y”.
Use the key to answer “Y” (YES) or the key
to answer “N” (NO) then press the SET key to
accept these changes and proceed to the next
menu item. Which menu item will be displayed
next is based on your answer to the question. In
the example above, if the answer were changed
to “N”, then the next item displayed would be
“PPA RATE 1 180.0” on the NH3 menu. If it was
answered “Y” the next item would be “GPA RATE
1 20.0” in the Spray menu.