![Hiniker 8160 Operator'S Manual Download Page 11](http://html.mh-extra.com/html/hiniker/8160/8160_operators-manual_2136894011.webp)
+++%
With the ERROR key selected the +++% mes-
sage will be displayed if the calculated percent
error between the target rate and the actual rate
is greater then +99%. In this condition you are
over applying by more then 99%.
DWG. NO. 5814
---%
With the ERROR key selected the ---% message
will be displayed if the calculated percent error
between the target rate and the actual rate is
greater then -99%. In this condition you are un-
der applying by more then 99%.
DWG. NO. 5815
MIN
Whenever the flow is reduced to the Minimum
Flow level, the display will flash “MIN” to indi
-
cate that the console will not reduce the flow any
further. You will be over-applying to keep a good
spray pattern.
DWG. NO. 5835
ERROR MESSAGES
Most error messages are displayed on the right
half of the display to inform the operator of spe-
cific conditions. Following is a description of
those messages.
LOW BATTERY CONDITION
This message is displayed whenever the battery
voltage at the console drops below ten volts. The
console suspends all operations until the normal
operating voltage level is resumed.
DWG. NO. 5811
HOLD
When displayed this reminds the operator that
the 8160 is in the Hold Mode and is no longer
doing any control. All boom valves are turned off
and Area and Volume stop accumulating.
DWG. NO. 5812
MAN ERR
This is displayed when the ERROR key is se-
lected and the Rate switch is in the “Manual” po-
sition.
DWG. NO. 5813
System Overview 9
Summary of Contents for 8160
Page 2: ......