Moldboard Problems 11
PLOW WILL NOT LOWER
Perform the Controller Test Procedure
DID CONTROLLER TEST OK?
No.
Yes.
|
Perform Under Hood Harness Test Procedure.
|
DID UNDER HOOD HARNESS TEST OK?
|
No.
Yes.
|
|
Perform Plow Harness Test Procedure.
|
|
DID PLOW HARNESS TEST OK?
|
|
No.
Yes.
|
|
|
Locate down hydraulic solenoid (See Power Unit Drawing).
|
|
|
Perform Hydraulic Solenoid Test Procedure.
|
|
|
DID DOWN SOLENOID TEST OK?
|
|
|
No.
Yes.
|
|
|
|
Hydraulic problem (See Hydraulic Unit Service Manual).
|
|
|
|
|
|
|
Replace down solenoid (See Hydraulic Unit Service Manual).
|
|
|
DID THIS FIND THE PROBLEM?
|
|
|
No.
Yes, done.
|
|
|
|
|
|
|
See Special Problems.
|
|
|
|
|
Check BROWN wire from J1 - 3 (plow harness) to down solenoid.
|
|
DID THIS FIND THE PROBLEM?
|
|
No.
Yes, done.
|
|
|
|
|
See Special Problems.
|
|
|
Check wiring between P2 - 2 (controller) to P1 - 3 (grill).
|
Note:
Wire color changes from RED between P2 - 2 & Relay Box,
|
to BROWN between Relay Box & P1 - 3.
|
DID THIS FIND THE PROBLEM?
|
No.
Yes, done.
|
|
|
See Special Problems.
|
DID TEST SHOW NO POWER TO CONTROLLER?
No.
Yes.
|
See No Controller Power.
|
Check J2 - 2 (controller) for damage.
DID THIS FIND THE PROBLEM?
No.
Yes, done.
|
Replace the controller.