10 Moldboard Problems
PLOW WILL NOT RAISE
Perform up.
DID PUMP MOTOR RUN?
No.
Yes.
|
Locate down hydraulic solenoid (See Power Unit Drawing).
|
Check if constantly on (See Hydraulic Solenoid Tests).
|
IS DOWN SOLENOID CONSTANTLY ON?
|
No.
Yes.
|
|
Perform the Controller Test Procedure.
|
|
DID CONTROLLER TEST OK?
|
|
No.
Yes.
|
|
|
Perform Under Hood Harness Test Procedure.
|
|
|
DID UNDER HOOD HARNESS TEST OK?
|
|
|
No.
Yes.
|
|
|
|
Perform Plow Harness Test Procedure.
|
|
|
|
DID PLOW HARNESS TEST OK?
|
|
|
|
No.
Yes.
|
|
|
|
|
Problem may be intermittent.
|
|
|
|
|
See Special Problems.
|
|
|
|
|
|
|
|
|
Check BROWN wire between J1 - 3 & down solenoid
|
|
|
|
for short to +12.
|
|
|
|
DID THIS FIND THE PROBLEM?
|
|
|
|
No.
Yes, done.
|
|
|
|
|
|
|
|
|
See Special Problems.
|
|
|
|
|
|
|
Check RED wire between P2 - 2 & Relay Box for short to +12.
|
|
|
Check BROWN wire between Relay Box & P1 - 3 for short to +12.
|
|
|
DID THIS FIND THE PROBLEM?
|
|
|
No.
Yes, done.
|
|
|
|
|
|
|
See Special Problems.
|
|
|
|
|
Replace the controller.
|
|
|
Hydraulic problem (See Hydraulic Unit Service Manual).
|
See Pump Will Not Run.