background image

NOTE

Depending on the version purchased, the slope adapter

and markers may not be included among the items sup-

plied.

2.3 Measuring principle

2

The transmitter generates a magnetic field. This magnetic

field is capable of penetrating, bricks, wood, concrete

and steel reinforced concrete. The receiver is calibrated

in such a way that it finds the center point of the projected

field and determines the applicable distance by measur-

ing the strength of the magnetic field between the two

units of the tool. The slope adapter has been designed for

use together with the transpointer so that the magnetic

field can be measured even when the receiver is placed

at an angle to the transmitter.

NOTE

The PX 10 transpointer is influenced by metal objects.

Whereas symmetrically arranged steel reinforcement in

concrete presents virtually no problem, welded reinforce-

ment, reinforcing mesh, flat sheet metal or solid metal

columns have a very negative effect on the performance

of the system.

3 Consumables

Accessories

Designation

Item number

Adhesive putty

PUA 91

273131

Adhesive strips

PUA 92

273132

Hand strap

PDA 60

282389

Slope adapter

PXA 70

273130

Markers

PUA 70

340806

4 Technical data

Right of technical changes reserved.

NOTE

The proximity of welded reinforcement, sheet metal or metal framing to the tool may have a considerable negative

effect on its accuracy. When wall thickness measurements are made through welded reinforcing mesh, the distance

displayed is approx. 20% greater. At temperatures below -10 °C (14 °F) considerable inaccuracy may occur with wall

thicknesses greater than 50 cm (1.64 ft).

Technical data

Values

Position-finding accuracy, standard (up to max. 1 m /

3 ft 3 in)

Tempe21°C (+70°F), Wall thickness 200 mm:

±8 mm (7.87 in: 0.32 in)

Position-finding accuracy, maximum (up to maximum

1 m / 3 ft 3 in, without influence by metal objects)

Tempe21°C (+70°F), Wall thickness 200 mm:

±2 mm (7.87 in: 0.08 in)

Wall thickness measurement accuracy (up to maximum

1 m / 3 ft 3 in, except when using the slope adapter)

Tempe21°C (+70°F): ±5 %

Measurement range (standard)

0.05…1.35 m (2 in to 4 ft 5 in)

Operating temperature (PX 10T, PX 10R, PUA 91)

-20…+55°C (-4 °F to +131 °F)

Operating temperature (PUA 92)

+10…+40°C (+50 °F to +104 °F)

Storage temperature

-25…+70°C (-13 °F to +158 °F)

Power source (PX 10T, PX 10R)

One 9 V battery in each

Battery life (PX 10T, PX 10R)

Tempe21°C (+70°F): 17 h

Automatic cut-out, PX 10T

17 min

Automatic cut-out, PX 10R

Without change in signal: 3 min, With change in signal:

8 min

Low battery indication (PX 10T)

Status indicator blinks: Remaining operating time: Min.

2 h

en

12

Printed: 07.07.2013 | Doc-Nr: PUB / 5136621 / 000 / 00

Summary of Contents for PX 10

Page 1: ...ruksanvisning no Bruksanvisning sv K ytt ohje fi Manual de instru es pt el Haszn lati utas t s hu N vod k obsluze cs N vod na obsluhu sk Instrukcja obs ugi pl Upute za uporabu hr Navodila za uporabo s...

Page 2: ...PX 10T PX 10T PX 10R PX 10R cm 90 9 0 40 80 7 0 6 0 5 0 40 1 2 3 4 7 9 8 4 4 6 5 PXA 70 PX 10R PX 10T PUA 91 PUA 92 1 Printed 07 07 2013 Doc Nr PUB 5136621 000 00...

Page 3: ...10R PX 10T 3 90 PX 10R PX 10R PX 10T PX 10T 90 4 40 5 0 6 0 7 0 8 0 90 a PX 10T PX 10R 6 40 50 60 70 80 90 8 40 5 0 6 0 7 0 8 0 90 70 PX 10T PX 10R 5 7 40 50 6 0 7 0 80 90 Printed 07 07 2013 Doc Nr P...

Page 4: ...500 mm 1 64 ft 1 500 mm 1 64 ft 500 mm 1 64 ft 500 mm 1 64 ft 2 3 1 1 3 3 2 2 4 4 4 max 6 mm max 0 24 inch 9 Printed 07 07 2013 Doc Nr PUB 5136621 000 00...

Page 5: ...o as the receiver In these operating instructions the designation the tool always refers to the PX 10 transpointer Operating controls and indicators 1 PX 10T transmitter On off button Status indicator...

Page 6: ...presentative or service department Type Serial no Location of identification data on the tool The type designation and serial number can be found on the type identification plate on the PX 10R receive...

Page 7: ...ta Right of technical changes reserved NOTE The proximity of welded reinforcement sheet metal or metal framing to the tool may have a considerable negative effect on its accuracy When wall thickness m...

Page 8: ...e user when drilling will not contact electric cables water or gas pipes or other objects Accordingly the greatest care and attention must always be exercised while working 5 3 Proper organization of...

Page 9: ...dirt and dust it has collected NOTE The adhesive putty leaves marks on the surface to which it is applied and may pull fragments away from it when removed If this presents a problem an alternative mea...

Page 10: ...red angle 3 To find the center point rotate the slope adapter according to the direction of slope to the point to be found 4 Take care to ensure that the adaptor base plate remains parallel to the und...

Page 11: ...and dried at maximum 40 C Repack the equipment only once it is completely dry Check the accuracy of the equipment before it is used after a long period of storage or transportation Remove the batteri...

Page 12: ...s are not clean Clean the contact surfaces 10 Disposal CAUTION Improper disposal of the equipment may have serious consequences The burning of plastic components generates toxic fumes which may presen...

Page 13: ...nties of merchantability or fitness for a particular purpose are specifically excluded For repair or replacement send the tool or related parts immediately upon discovery of the defect to the address...

Page 14: ...ollowing measures Re orient or re locate the receiving antenna Increase the distance between the equipment and receiver Connect the equipment to an outlet on a circuit differ ent from that to which th...

Page 15: ...l 423 2342111 Fax 423 2342965 www hilti com Hilti registered trademark of Hilti Corp Schaan W 3155 0313 00 Pos 1 1 Printed in Germany 2013 Right of technical and programme changes reserved S E O 31993...