background image

7.6.4 Measuring wall thickness

Determining the thickness of walls, ceilings or floors.

7.7 Measurements to check accuracy

9

NOTE

Check the accuracy of the tool before making important

measurements or if the instrument has been dropped.

NOTE

Do not measure in corners or immediately adjacent to

concrete walls containing steel reinforcement. In order to

avoid influence by metal objects, it is recommended that

the actual measurements are made at points offset from

the reference point by a defined distance (for example,

200 mm / 8 in).

1. Choose a wall with a thickness of approx. 50 cm

(1.64 ft) that is known to contain no reinforcement

and with surfaces that are known to be parallel.

2. Check that the PX 10T is secured in position and

then use the receiver to make measurements from

four sides (from above, below, right, left). Mark the

points found and then determine the geometrical

center.

NOTE

Calibration at a Hilti service center is neces-

sary if a deviation of more than 6 mm (0.24 in) is

found.

3. If you doubt whether the surfaces of the wall are

parallel, swap the positions of the transmitter and

receiver on each side of the wall and repeat the

steps described previously. Set up the transmitter

on the previously determined geometrical center. If

the second geometrical center does not coincide

with the original reference point, then the surfaces

of the wall are not parallel.

8 Care and maintenance

8.1 Cleaning and drying

Use only a clean, soft cloth for cleaning. If necessary,

moisten the cloth slightly with pure alcohol or a little

water.

NOTE

Do not use any other liquids as these may damage the

plastic components.

8.2 Storage

Unpack the tool if it has become wet. The tool, its carrying

case and accessories should be cleaned and dried (at

maximum 40°C). Repack the equipment only once it is

completely dry.

Check the accuracy of the equipment before it is used

after a long period of storage or transportation.

Remove the batteries from the tool before storing it for a

long period.

NOTE

- Leaking batteries may damage the tool.

- Observe the temperature limits when storing your

equipment, especially in winter / summer if the equip-

ment is kept inside a motor vehicle (-25°C to +70°C;

-13 °F to +158 °F).

8.3 Transport

Use the Hilti toolbox or packaging of equivalent quality

for transporting or shipping your equipment.

CAUTION

Always remove the batteries before shipping the tool.

8.4 Hilti calibration service

We recommend that the tool is checked by the Hilti cal-

ibration service at regular intervals in order to verify its

reliability in accordance with standards and legal require-

ments.

Use can be made of the Hilti calibration service at any

time, but checking at least once a year is recommended.

The calibration service provides confirmation that the

tool is in conformance, on the day it is checked, with the

specifications given in the operating instructions.

After checking, a calibration sticker applied to the tool and

a calibration certificate provide written verification that the

tool is operating in accordance with the manufacturer’s

specification.

Calibration certificates are always required by companies

certified according to ISO 900x.

Your local Hilti Center or representative will be pleased

to provide further information.

9 Troubleshooting

Fault

Possible cause

Remedy

The receiver is switched on but

no signal is indicated on the

display.

The transmitter has switched off auto-

matically after 17 minutes.

Switch on the transmitter.

The PX 10T transmitter battery is

dead.

Change the battery.

The maximum measuring range has

been exceeded.

Make the measurements where the

wall is less thick and then measure

the offset to the drilling position.

en

16

Printed: 07.07.2013 | Doc-Nr: PUB / 5136621 / 000 / 00

Summary of Contents for PX 10

Page 1: ...ruksanvisning no Bruksanvisning sv K ytt ohje fi Manual de instru es pt el Haszn lati utas t s hu N vod k obsluze cs N vod na obsluhu sk Instrukcja obs ugi pl Upute za uporabu hr Navodila za uporabo s...

Page 2: ...PX 10T PX 10T PX 10R PX 10R cm 90 9 0 40 80 7 0 6 0 5 0 40 1 2 3 4 7 9 8 4 4 6 5 PXA 70 PX 10R PX 10T PUA 91 PUA 92 1 Printed 07 07 2013 Doc Nr PUB 5136621 000 00...

Page 3: ...10R PX 10T 3 90 PX 10R PX 10R PX 10T PX 10T 90 4 40 5 0 6 0 7 0 8 0 90 a PX 10T PX 10R 6 40 50 60 70 80 90 8 40 5 0 6 0 7 0 8 0 90 70 PX 10T PX 10R 5 7 40 50 6 0 7 0 80 90 Printed 07 07 2013 Doc Nr P...

Page 4: ...500 mm 1 64 ft 1 500 mm 1 64 ft 500 mm 1 64 ft 500 mm 1 64 ft 2 3 1 1 3 3 2 2 4 4 4 max 6 mm max 0 24 inch 9 Printed 07 07 2013 Doc Nr PUB 5136621 000 00...

Page 5: ...o as the receiver In these operating instructions the designation the tool always refers to the PX 10 transpointer Operating controls and indicators 1 PX 10T transmitter On off button Status indicator...

Page 6: ...presentative or service department Type Serial no Location of identification data on the tool The type designation and serial number can be found on the type identification plate on the PX 10R receive...

Page 7: ...ta Right of technical changes reserved NOTE The proximity of welded reinforcement sheet metal or metal framing to the tool may have a considerable negative effect on its accuracy When wall thickness m...

Page 8: ...e user when drilling will not contact electric cables water or gas pipes or other objects Accordingly the greatest care and attention must always be exercised while working 5 3 Proper organization of...

Page 9: ...dirt and dust it has collected NOTE The adhesive putty leaves marks on the surface to which it is applied and may pull fragments away from it when removed If this presents a problem an alternative mea...

Page 10: ...red angle 3 To find the center point rotate the slope adapter according to the direction of slope to the point to be found 4 Take care to ensure that the adaptor base plate remains parallel to the und...

Page 11: ...and dried at maximum 40 C Repack the equipment only once it is completely dry Check the accuracy of the equipment before it is used after a long period of storage or transportation Remove the batteri...

Page 12: ...s are not clean Clean the contact surfaces 10 Disposal CAUTION Improper disposal of the equipment may have serious consequences The burning of plastic components generates toxic fumes which may presen...

Page 13: ...nties of merchantability or fitness for a particular purpose are specifically excluded For repair or replacement send the tool or related parts immediately upon discovery of the defect to the address...

Page 14: ...ollowing measures Re orient or re locate the receiving antenna Increase the distance between the equipment and receiver Connect the equipment to an outlet on a circuit differ ent from that to which th...

Page 15: ...l 423 2342111 Fax 423 2342965 www hilti com Hilti registered trademark of Hilti Corp Schaan W 3155 0313 00 Pos 1 1 Printed in Germany 2013 Right of technical and programme changes reserved S E O 31993...

Reviews: