background image

26

27

Selecting and setting the menu, continued

dELAY menu / self-timer

3. Operation

CONST menu / constants

Light menu / display illumination

Press the 

 button

to select menu mode.

Use the 

buttons to select the
CONST menu.

Use the 

 buttons to enter the constant,

e.g. 0.234
The value entered can be recalled for use in
subsequent calculations (e.g. addition of a
constant to the measured value etc).

Press the 

 button

to select menu mode.

Use the 

buttons to select the
light menu.

Use the 

 buttons to select the desired

illumination mode:

OFF

illumination off (power saving)

ON

illumination on constantly

AUTO

illumination on for 10 seconds after
pressing a button

Press the 

 button

to select menu mode.

Use the 

buttons to select the
dELAY menu.

Use the 

 buttons to select the desired

delay time 

(0 / 2 / 5 /10 / 20)

.

After pressing the “measure” button, the
measurement will be taken automatically when
the set time has elapsed (e.g. for taking
measurements from points where access is
difficult).

continued 

MENU

CONST

0.234

MENU

Light

OFF

MENU

dELAY

0

3. Operation

 Menu selection and setting

rEF menu / reference point

continued 

Menu overview

Select menu mode by
pressing the 
button.

Use the 

buttons to select the
rEF menu.

MENU

rEF

Front edge of the tool

Tripod thread axis

Rear edge of the tool

 (standard

setting)

Use the 

 buttons to select the desired

reference point:

Press the 

 button to exit menu mode.

rEF 

 CONSt 

 Light 

dELAY 

 bEEP 

 UNIT

Select / exit menu mode

Scroll through the menus

Adjust menu values up / down

Summary of Contents for PD 20

Page 1: ...PD 20 Operating instructions 334057 334057...

Page 2: ...nstructions carefully before using the product The symbols used in these operating instructions have the following meanings 1 Product information 5 Description of functions 5 Display and control panel...

Page 3: ...o tripod mounting threads Taking measurements from various surfaces 34 Using the calculation functions 35 Adding subtracting distances 35 Multiplication areas volumes 36 Calculating with Pythagoras 38...

Page 4: ...ng threads Description of functions continued Distances between 30 and 100 m Use the brown target plate Distances between 0 3 and 30 m Target the object directly Use the white target plate The point f...

Page 5: ...IT Recall last measured values max 3 Scroll through active menu Measure distance or start tracking Addition Subtraction Multiplication Pythagoras calculates length of opposite side of right angled tri...

Page 6: ...0 C 50 C 0 2 32 F 122 F 7 mm 10 C 50 C 0 3 14 F 122 F Beam diameter 6 mm 10 m 0 2 30 ft 30 mm 50 m 1 2 150 ft 60 mm 100 m 2 4 300 ft Operating modes Individual measurement Continuous measurement Pre...

Page 7: ...seconds Alkaline 4000 NiCd 2000 Battery condition A warning is displayed when battery voltage is low Operating temperature 10 C 50 C 14 F 122 F Storage temperature 30 C 70 C 22 F 158 F Protection cla...

Page 8: ...he Hilti product Intended use continued continued 2 Safety information 2 Safety information Please read this now This information is intended to enable owners and users of the Hilti PD 20 to identify...

Page 9: ...in distance while in tracking mode or rapidly moving target objects may lead to measurement errors Operating risks continued continued 2 Safety information Responsibility of the owner WARNING The owne...

Page 10: ...the laser beam while measuring may lead to incorrect measurements Preventative measures Take care to ensure that no objects move through the path of the laser beam CAUTION Inadmissible mechanical infl...

Page 11: ...lowing Burning of plastic components generates toxic fumes which may present a health hazard If damaged or exposed to very high temperatures batteries may explode causing poisoning burns acid burns or...

Page 12: ...Pulse duration 1 x 10 9 s 1 x 10 9 s Max power output 0 95 mW 5 0 95 mW 5 Caution The product should be repaired at a Hilti approved service centre only Laser classification continued 2 Safety inform...

Page 13: ...tatic discharge without causing electromagnetic interference to other devices WARNING There may be a possibility of interference with other equipment due to electromagnetic radiation Although the Hilt...

Page 14: ...a button Press the button to select menu mode Use the buttons to select the dELAY menu Use the buttons to select the desired delay time 0 2 5 10 20 After pressing the measure button the measurement w...

Page 15: ...h the PD 20 LASER bEEP menu beep sound Unit menu measurement units Selecting and setting the menu continued 3 Operation Press the button to select menu mode Use the buttons to select the bEEP menu Use...

Page 16: ...Tracking mode can be cancelled by pressing any button 1 010m Measuring using the spike 4 Working with the PD 20 Measuring distances continued The spike should be folded out when measuring the diagonal...

Page 17: ...e g for measuring from inaccessible positions The use of an extension rod can be of great assistance for measuring with the PD 20 from points where access is difficult or even impossible to reach with...

Page 18: ...art height position the PD 20 pointing downwards with its rear edge on the line marked on the wall Press the measure button again The second part height is measured and displayed the laser beam then s...

Page 19: ...n of calculations can also be made without pressing the equals button For example distance x distance x distance or distance x distance distance x distance m2 29 313 m2 x 2 285 m Multiplication areas...

Page 20: ...h Pythagoras The Pythagoras function button can be used for example for quickly measuring remote heights etc Pressing the Pythagoras button activates the calculation formula To ensure correct use of t...

Page 21: ...ously increases or respectively decreases the indicated value in increments of 0 100 When making calculations use the buttons to recall the previously entered constant value as the fourth or respectiv...

Page 22: ...ocedure Your PD 20 conforms to the specified accuracy if the standard deviation remains less than or equal to 5mm A PD 20 which has been tested inspected over the test distance will operate with the a...

Page 23: ...se harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the fol...

Page 24: ...mage losses or costs incurred in connection with the use of or due to the impossibility of using the device for any purpose Implicit warranties of the applicability or suitability of the device for a...

Page 25: ...Hilti Registered trademark of Hilti Corp Schaan Right of technical and programme changes reserved W2363 1199 10 englisch 9 Printed in Liechtenstein 1999 S E O 334057...