2. Safety information

WARNING

Misuse may lead to injury, malfunction
and damage to property. The owner
must inform the user of the operating
risks associated with the equipment
and the corresponding safety
precautions. The PD 20 laser range
meter may be operated only when the
user has received prior instruction.

Operating limits

See “Technical data” section.

Environment

The product is suitable for use in atmospheres
permanently habitable by humans. It must not
be used in corrosive or explosive environments.
Exposure to rain for short periods during use is
permissible.

Division of responsibilities

Responsibility of the manufacturer of
the original equipment, Hilti Corporation,
FL 9494 Schaan (subsequently referred to
as “Hilti”)

Hilti is responsible for supplying a technically
safe product in faultless condition, including
operating instructions and original accessories.

The responsibility of other manufacturers
supplying accessories

The manufacturers of accessories (not supplied
by Hilti) for the Hilti PD 20 are responsible for
the development, implementation and
communication of safety strategies for their
products and the interaction of the latter with the
Hilti product.

Intended use, continued

continued 

2. Safety information

2. Safety information

Please read this now!

This information is intended to enable owners
and users of the Hilti PD 20 to identify any
operating risks in good time, i.e. to eliminate any
such risks in advance where possible.
The owner of the tool must ensure that these
instructions are understood and followed by all
users.

Purpose

Intended uses

The Hilti PD 20 is intended for the following
range of applications:
• Measuring distances
• Calculating areas, volumes and remote

heights (side of right-angled triangle)

• Addition and subtraction of distances

Examples of misuse

• Use of the product without prior instruction
• Use of the product outside its operating limits
• Rendering safety devices ineffective or

removing notices and warning signs

• Opening the product unless expressly

permitted in certain cases (e.g. to replace the
batteries)

• Making conversions or modifications to the

product

• The use of accessories from other

manufacturers not explicitly approved by Hilti

• The use of a product known to have been

stolen

• Deliberately dangerous or careless behaviour

on scaffolding, when climbing ladders or
when taking measurements in the vicinity of
operating machinery or the exposed parts of
machines or other equipment

• Aiming the product directly at the sun
• Deliberately dazzling other persons

continued 

Summary of Contents for PD 20

Page 1: ...PD 20 Operating instructions 334057 334057...

Page 2: ...nstructions carefully before using the product The symbols used in these operating instructions have the following meanings 1 Product information 5 Description of functions 5 Display and control panel...

Page 3: ...o tripod mounting threads Taking measurements from various surfaces 34 Using the calculation functions 35 Adding subtracting distances 35 Multiplication areas volumes 36 Calculating with Pythagoras 38...

Page 4: ...ng threads Description of functions continued Distances between 30 and 100 m Use the brown target plate Distances between 0 3 and 30 m Target the object directly Use the white target plate The point f...

Page 5: ...IT Recall last measured values max 3 Scroll through active menu Measure distance or start tracking Addition Subtraction Multiplication Pythagoras calculates length of opposite side of right angled tri...

Page 6: ...0 C 50 C 0 2 32 F 122 F 7 mm 10 C 50 C 0 3 14 F 122 F Beam diameter 6 mm 10 m 0 2 30 ft 30 mm 50 m 1 2 150 ft 60 mm 100 m 2 4 300 ft Operating modes Individual measurement Continuous measurement Pre...

Page 7: ...seconds Alkaline 4000 NiCd 2000 Battery condition A warning is displayed when battery voltage is low Operating temperature 10 C 50 C 14 F 122 F Storage temperature 30 C 70 C 22 F 158 F Protection cla...

Page 8: ...he Hilti product Intended use continued continued 2 Safety information 2 Safety information Please read this now This information is intended to enable owners and users of the Hilti PD 20 to identify...

Page 9: ...in distance while in tracking mode or rapidly moving target objects may lead to measurement errors Operating risks continued continued 2 Safety information Responsibility of the owner WARNING The owne...

Page 10: ...the laser beam while measuring may lead to incorrect measurements Preventative measures Take care to ensure that no objects move through the path of the laser beam CAUTION Inadmissible mechanical infl...

Page 11: ...lowing Burning of plastic components generates toxic fumes which may present a health hazard If damaged or exposed to very high temperatures batteries may explode causing poisoning burns acid burns or...

Page 12: ...Pulse duration 1 x 10 9 s 1 x 10 9 s Max power output 0 95 mW 5 0 95 mW 5 Caution The product should be repaired at a Hilti approved service centre only Laser classification continued 2 Safety inform...

Page 13: ...tatic discharge without causing electromagnetic interference to other devices WARNING There may be a possibility of interference with other equipment due to electromagnetic radiation Although the Hilt...

Page 14: ...a button Press the button to select menu mode Use the buttons to select the dELAY menu Use the buttons to select the desired delay time 0 2 5 10 20 After pressing the measure button the measurement w...

Page 15: ...h the PD 20 LASER bEEP menu beep sound Unit menu measurement units Selecting and setting the menu continued 3 Operation Press the button to select menu mode Use the buttons to select the bEEP menu Use...

Page 16: ...Tracking mode can be cancelled by pressing any button 1 010m Measuring using the spike 4 Working with the PD 20 Measuring distances continued The spike should be folded out when measuring the diagonal...

Page 17: ...e g for measuring from inaccessible positions The use of an extension rod can be of great assistance for measuring with the PD 20 from points where access is difficult or even impossible to reach with...

Page 18: ...art height position the PD 20 pointing downwards with its rear edge on the line marked on the wall Press the measure button again The second part height is measured and displayed the laser beam then s...

Page 19: ...n of calculations can also be made without pressing the equals button For example distance x distance x distance or distance x distance distance x distance m2 29 313 m2 x 2 285 m Multiplication areas...

Page 20: ...h Pythagoras The Pythagoras function button can be used for example for quickly measuring remote heights etc Pressing the Pythagoras button activates the calculation formula To ensure correct use of t...

Page 21: ...ously increases or respectively decreases the indicated value in increments of 0 100 When making calculations use the buttons to recall the previously entered constant value as the fourth or respectiv...

Page 22: ...ocedure Your PD 20 conforms to the specified accuracy if the standard deviation remains less than or equal to 5mm A PD 20 which has been tested inspected over the test distance will operate with the a...

Page 23: ...se harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the fol...

Page 24: ...mage losses or costs incurred in connection with the use of or due to the impossibility of using the device for any purpose Implicit warranties of the applicability or suitability of the device for a...

Page 25: ...Hilti Registered trademark of Hilti Corp Schaan Right of technical and programme changes reserved W2363 1199 10 englisch 9 Printed in Liechtenstein 1999 S E O 334057...

Reviews: