![Hilti HIT-RE 100 Manual Download Page 8](http://html1.mh-extra.com/html/hilti/hit-re-100/hit-re-100_manual_2136264008.webp)
Hilti HIT-RE 100 mortar w/
rebar (as post-installed conn.)
04 / 2016
9
Setting the element
Before use verify that the element is dry and free of oil and other
contaminants.
For easy installation insert the rebar slowly twisted into the drill hole
until the embedment mark is at the concrete surface level.
For overhead application:
During insertion of the rebar, mortar might flow out of the borehole.
For collection of the flowing mortar, HIT-OHC may be used.
Support the rebar and secure it from falling till mortar started to
harden, e.g. using wedges HIT-OHW.
For overhead installation use piston plugs and fix embedded parts
with e.g. wedges.
After installing the rebar the annular gap must be completely filled
with mortar.
Proper installation:
desired anchoring embedment l
v
is reached: embedment
mark at concrete surface.
excess mortar flows out of the drill hole after the rebar has
been fully inserted until the embedment mark.
Observe the working time t
work
, which varies according to temperature
of base material. Minor adjustments to the rebar position may be
performed during the working time.
Full load may be applied only after the curing time t
cure
has elapsed.