background image

Hilti HIT-RE 100 mortar w/     
rebar (as post-installed conn.) 

 

 
 

04 / 2016                                                                                                                                                                                                                             12                

 

 

Pre-calculated values of anchorage length for characteristic steel strength  
f

yk

= 500 N/mm

2

 

 

For Hammer drilling and Compressed air drilling 

Rebar 

Concrete 

class 

f

bd

 

N

Rd,s 

l

0,min

1)

 

l

b,min

2)

 

l

bd,y

,α2=1

3)

 

l

bd,y, α2=0.7

4)

 

[mm] 

 

[N/mm

2

[kN] 

[mm] 

[mm] 

[mm] 

[mm] 

C20/25 

2,3 

21,9 

200 

113 

378 

265 

C50/60 

4,3 

21,9 

200 

100 

202 

142 

10 

C20/25 

2,3 

34,1 

200 

142 

473 

331 

10 

C50/60 

4,3 

34,1 

200 

100 

253 

177 

12 

C20/25 

2,3 

49,2 

200 

170 

567 

397 

12 

C50/60 

4,3 

49,2 

200 

120 

303 

212 

14 

C20/25 

2,3 

66,9 

210 

198 

662 

463 

14 

C50/60 

4,3 

66,9 

210 

140 

354 

248 

16 

C20/25 

2,3 

87,4 

240 

227 

756 

529 

16 

C50/60 

4,3 

87,4 

240 

160 

404 

283 

18 

C20/25 

2,3 

110,6 

270 

255 

851 

596 

18 

C50/60 

4,3 

110,6 

270 

180 

455 

319 

20 

C20/25 

2,3 

136,6 

300 

284 

945 

662 

20 

C50/60 

4,3 

136,6 

300 

200 

506 

354 

22 

C20/25 

2,3 

165,3 

330 

312 

1040 

728 

22 

C50/60 

4,3 

165,3 

330 

220 

556 

389 

24 

C20/25 

2,3 

196,6 

360 

340 

1134 

794 

24 

C50/60 

4,3 

196,6 

360 

240 

607 

425 

25 

C20/25 

2,3 

213,4 

375 

354 

1181 

827 

25 

C50/60 

4,3 

213,4 

375 

250 

632 

442 

26 

C20/25 

2,3 

230,9 

390 

369 

1229 

860 

26 

C50/60 

4,3 

230,9 

390 

260 

657 

460 

28 

C20/25 

2,3 

267,7 

420 

397 

1323 

926 

28 

C50/60 

4,3 

267,7 

420 

280 

708 

495 

30 

C20/25 

2,3 

307,3 

450 

425 

1418 

992 

30 

C50/60 

4,3 

307,3 

450 

300 

758 

531 

32 

C20/25 

2,3 

349,7 

480 

454 

1512 

1059 

32 

C50/60 

4,3 

349,7 

480 

320 

809 

566 

34 

C20/25 

2,3 

395,0 

510 

482 

1607 

1125 

34 

C50/60 

4,2 

395,0 

510 

340 

880 

616 

36 

C20/25 

2,2 

442,8 

540 

534 

1779 

1245 

36 

C50/60 

4,1 

442,8 

540 

360 

955 

668 

40 

C20/25 

2,1 

546,6 

621 

621 

2071 

1450 

40 

C50/60 

4,0 

546,6 

621 

400 

1087 

761 

1): Minimum anchorage length for overlap joint 
2): Minimum anchorage length for simply supported connections 
3): Anchorage length for simply supported connections in case of: α

1

= α

2

= α

3

= α

4

= α

5

= 1 

4): 

Anchorage length for simply supported connections in case of: α

1

α

3

α

4

α

5

1; α

2

= 0.7 

 
 

Summary of Contents for HIT-RE 100

Page 1: ...suitable for embedment length till 3200 mm Statik mixer Rebar Base material Load conditions Concrete Dry concrete Wet concrete Static quasi static Installation conditions Other informations Hammer dri...

Page 2: ...6 Setting details For detailed information on installation see instruction for use given with the package of the product Curing time for general conditions 1 Data according ETA 15 0883 issue xxx Tempe...

Page 3: ...drill hole the drill hole shall be filled with mortar Drill the hole to the required embedment depth using a hammer drill with carbid drill bit set in rotation hammer mode a compressed air drill or a...

Page 4: ...essed air cleaning CAC For all drill hole diameters d0 and all drill hole depths h0 20 d Blow 2 times from the back of the hole if needed with nozzle extension over the whole length with oil free comp...

Page 5: ...DRS is recommended In addition for wet diamond corind DD For all drill hole diameters d0 and all drill hole depths h0 Flush 2 times by inserting a water hose water line pressure to the back of the ho...

Page 6: ...d above For each new foil pack a new mixing nozzle must be used Discard quantities are 3 strokes for 330 ml foil pack 4 strokes for 500 ml foil pack 65 ml for 1400 ml foil pack Inject adhesive Inject...

Page 7: ...ction Mark the required mortar level m and embedment depth v with tape or marker on the injection extension estimation lm 1 3 lv precise formula for optimum mortar volume lm lv 1 2 2 d0 2 0 2 For over...

Page 8: ...it from falling till mortar started to harden e g using wedges HIT OHW For overhead installation use piston plugs and fix embedded parts with e g wedges After installing the rebar the annular gap mus...

Page 9: ...Diamond coring Dry PCC Wet DD 8 12 10 a 12 10 a 10 14 12 a 14 12 a 12 16 14 a 17 16 14 a 14 18 17 18 16 20 20 20 18 22 22 22 20 25 24 b 26 25 22 28 28 28 24 32 32 35 32 25 32 30 b 32 30 b 35 32 26 35...

Page 10: ...ions multiply the values by 0 7 Bond strength in N mm according to ETA 15 0883 for good bond conditions diamond coring wet Rebar mm Concrete class C12 15 C16 20 C20 25 C25 30 C30 37 C35 45 C40 50 C45...

Page 11: ...22 C20 25 2 3 165 3 330 312 1040 728 22 C50 60 4 3 165 3 330 220 556 389 24 C20 25 2 3 196 6 360 340 1134 794 24 C50 60 4 3 196 6 360 240 607 425 25 C20 25 2 3 213 4 375 354 1181 827 25 C50 60 4 3 21...