Setting up the wall saw system
7. Setting up the wall saw system
Connecting the power unit
NOTE
Operating the main swith several times in quick succession will cause the electric supply to be temporarily inter-
rupted. Wait for a few seconds before switching on again.
1. Set the current input limiter
to the corresponding fuse rating. Connect the earth/ground terminal
to an
earth/ground rod if the unit is powered by a generator.
2. Connect the power cable
(observe the information on the type plate
).
3. Remove the protective cap and connect and secure the remote control unit
.
4. Close the protective caps
by fitting them together.
5. Move the main switch
to the “I” position. The “Ready” indicator
then lights.
6. Connect the external cooling water hose
. Water pressure must not exceed 6 bar.
7.1
Parts
No.
Designation
Error indicator (red)
“Ready” indicator (green)
Main switch
Current input limiter
230 V power outlet (only with 3
×
400 V version)
Automatic fuse / circuit breaker and ready indi-
cator for 230 V outlet
Power cable connector
Socket for remote control unit
Cooling water connection (feed)
Type plate
Plug for saw head control cable
Plug for saw head power cable
Cooling water connection (exit)
Earth/ground terminal