*434949*
434949
English
43
8.1
The diamond core drilling machine is not in working order.
Malfunction
Possible cause
Action to be taken
The service indicator shows
nothing.
The PRCD isn’t switched on.
▶
Check that the PRCD is
functioning and switch it on.
Interruption in the electric supply.
▶
Plug in another electric tool or
appliance and check whether it
works.
▶
Check the plug connections,
supply cord, power supply line
and main supply fuse.
Water in the motor.
▶
Allow the diamond core drilling
machine to dry out completely
in a warm, dry place.
The service indicator lights.
The carbon brushes are worn out.
▶
Replace the carbon brushes.
The service indicator blinks.
The motor has overheated.
▶
Wait a few minutes until the
motor has cooled down or
allow the diamond core drilling
machine to run under no load in
order to speed up the cooling
process. Switch the diamond
core drilling machine off and
then on again.
Overload error.
▶
Switch the diamond core drilling
machine off and then on again.
▶
Guide the diamond core drilling
machine straight and/or apply
less drilling pressure.
The theft protection indicator
blinks.
The diamond core drilling machine
has not been unlocked (machines
with optional theft protection sys-
tem).
▶
Use the TPS key to unlock the
diamond core drilling machine.
8.2
The diamond core drilling machine is in working order
Malfunction
Possible cause
Action to be taken
The service indicator lights.
The carbon brush wear limit has
almost been reached. The diamond
core drilling machine will continue
to run for a few hours until it shuts
down automatically.
▶
Have the carbon brushes
replaced at the next opportunity.
The carbon brushes have been
changed and must be run in.
▶
Run in the carbon brushes by
letting the machine run under
no load for at least 1 minute
without interruption.
The diamond core drilling
machine doesn’t achieve full
performance.
Supply network fault – undervolt-
age occurred.
▶
Check whether other power
consumers are disrupting the
power supply from the network
or generator.
▶
Check the length of the exten-
sion cord used.
The diamond core bit doesn’t
rotate.
The gear selector isn’t engaged.
▶
Operate the gear selector until
it engages.
Printed: 09.08.2019 | Doc-Nr: PUB / 5069546 / 000 / 09
Summary of Contents for DD 150-U
Page 2: ...1 Printed 09 08 2019 Doc Nr PUB 5069546 000 09...
Page 3: ...2 3 4 5 Printed 09 08 2019 Doc Nr PUB 5069546 000 09...
Page 4: ...6 7 8 9 Printed 09 08 2019 Doc Nr PUB 5069546 000 09...
Page 5: ...10 11 12 13 Printed 09 08 2019 Doc Nr PUB 5069546 000 09...
Page 6: ...14 15 Printed 09 08 2019 Doc Nr PUB 5069546 000 09...
Page 8: ...Printed 09 08 2019 Doc Nr PUB 5069546 000 09...
Page 261: ...434949 434949 253 Printed 09 08 2019 Doc Nr PUB 5069546 000 09...
Page 262: ...254 434949 434949 2 2 2 3 Printed 09 08 2019 Doc Nr PUB 5069546 000 09...
Page 263: ...434949 434949 255 Hilti P2 PRCD PRCD PRCD Printed 09 08 2019 Doc Nr PUB 5069546 000 09...
Page 264: ...256 434949 434949 3 3 1 1 on off PRCD Q W E R T Printed 09 08 2019 Doc Nr PUB 5069546 000 09...
Page 278: ...270 434949 434949 269 8 2 1 Printed 09 08 2019 Doc Nr PUB 5069546 000 09...
Page 279: ...434949 434949 271 Printed 09 08 2019 Doc Nr PUB 5069546 000 09...
Page 280: ...272 434949 434949 90 90 263 9 Hilti Hilti Hilti Printed 09 08 2019 Doc Nr PUB 5069546 000 09...
Page 329: ...434949 434949 321 1 2 3 1 3 1 3 1 1 3 2 1 3 3 Printed 09 08 2019 Doc Nr PUB 5069546 000 09...
Page 332: ...324 434949 434949 2 2 Printed 09 08 2019 Doc Nr PUB 5069546 000 09...
Page 333: ...434949 434949 325 2 3 Hilti Printed 09 08 2019 Doc Nr PUB 5069546 000 09...
Page 334: ...326 434949 434949 P2 Printed 09 08 2019 Doc Nr PUB 5069546 000 09...
Page 349: ...434949 434949 341 8 1 340 8 2 Printed 09 08 2019 Doc Nr PUB 5069546 000 09...
Page 350: ...342 434949 434949 Printed 09 08 2019 Doc Nr PUB 5069546 000 09...
Page 532: ...524 Eesti 434949 434949 Printed 09 08 2019 Doc Nr PUB 5069546 000 09...
Page 533: ...Printed 09 08 2019 Doc Nr PUB 5069546 000 09...