Before work starts, remove the air inlet cover.

1. Make sure that the product is steady and cannot topple.

2. To switch on, turn the control switch to the stage 2 position (full power).

3. To switch off, turn the control switch to the

OFF

position.

6.1

Integration into dust-stop partition wall

2

You can operate the product with an extraction hose or integrate it directly into a dust-stop partition wall with

the dust-stop partition wall adapter and vacuum dust out of the inside of the dust-stop partition wall without

the product being directly in the room. To operate the product with an intake hose connected or integrate

the product directly into a dust-stop partition wall, the shutters on both sides of the product must be closed.
1. Pull the dust-stop partition wall adapter off air inlet cover

(1)

.

2. Position the product at the dust-stop partition wall.

3. Use the dust-stop partition wall adapter to secure the dust-stop partition wall to the air inlet.

Turn the dust-stop partition wall adapter through 180° so that the inner ring fits into the air inlet.

4. If necessary, cut an opening into the dust-stop partition wall secured to the air inlet.

5. Shut off the side filters by pulling the shutter up.

6. Switch the tool on.

6.2

Replacing pre-filters

3

1. Switch the air cleaner off and wait until the turbine runs down to a complete stop.

2. Open the pre-filter cover

(1)

.

3. Remove the pre-filter and insert a new pre-filter

(2)

.

4. Remove dust residues.

5. Close the pre-filter cover

(3)

.

6.3

Replacing main filters

4

1. Switch the air cleaner off and wait until the turbine runs down to a complete stop.

2. Open both toggle catches and remove the housing cover by lifting it up

(1)

.

3. Remove heavy accretions of dust inside the housing with a vacuum cleaner.

Ascertain the dust class of the dust and use a vacuum cleaner approved for the dust class.

4. Remove the pre-filters

(2)

.

5. Remove dust residues.

6. Open the rotary catches (3) and replace the main filter

(4)

.

7. Replace the pre-filters

(5)

.

8. Lower the housing cover into position

(6)

and seal the filter cover by closing the toggle catches

(7)

.

7

Care and maintenance

WARNING

Electric shock hazard!

Attempting care and maintenance with the supply cord connected to a power outlet

can lead to severe injury and burns.

Always unplug the supply cord before carrying out care and maintenance tasks.

Care

• Carefully remove stubborn dirt from the tool.

• Clean the air vents carefully with a dry brush.

• Use only a slightly damp cloth to clean the casing. Do not use cleaning agents containing silicone as

they can attack the plastic parts.

Summary of Contents for AIC 600

Page 1: ...AIC 600 English 1 Espa ol 8 Fran ais 16...

Page 2: ...1...

Page 3: ...2 3 4...

Page 4: ...AIC 600 en Original operating instructions 1 es Manual de instrucciones original 8 fr Notice d utilisation originale 16...

Page 5: ...at can lead to serious injury or fatality CAUTION CAUTION Draws attention to a potentially dangerous situation that could lead to personal injury or damage to the equipment or other property 1 2 2 Sym...

Page 6: ...tool before use and comply with all the instructions and warnings Do not tamper with or attempt to make alterations to the product Use the right product for the job Do not use the product for purpose...

Page 7: ...from the power outlet Use the power outlet on the product only for the purposes described in the operating instructions Never operate the product when it is dirty or wet Dust especially dust from con...

Page 8: ...been disconnected from the power outlet Do not use the product to filter hot or incandescent fragments or particles Make sure that the temperature of the inducted contaminated air does not exceed 60...

Page 9: ...9 4 CFM 476 4 s Max vacuum 500 Pa 0 073 psi 5 Use of extension cords Use of extension cords WARNING A damaged supply cord presents a hazard Do not touch the supply cord or extension cord if it is dama...

Page 10: ...de filters by pulling the shutter up 6 Switch the tool on 6 2 Replacing pre filters 3 1 Switch the air cleaner off and wait until the turbine runs down to a complete stop 2 Open the pre filter cover 1...

Page 11: ...ilters 8 Transport and storage Transport Do not transport this product with an accessory installed for example the extraction hose Make sure that the equipment is held securely throughout all transpor...

Page 12: ...hilti com manual id 2297302 This link is also to be found at the end of the documentation in the form of a QR code Manual de instrucciones original 1 Informaci n sobre la documentaci n 1 1 Acerca de...

Page 13: ...usuarios profesionales y solo personal autorizado y debidamente formado puede utilizarlos y llevar a cabo su mantenimiento y conservaci n Este personal debe estar especialmente instruido en lo refere...

Page 14: ...baci n o la reparaci n del producto a un servicio t cnico homologado de Hilti No tienda el cable de red bajo una alfombra ni por debajo de muebles u otros aparatos No cubra el cable de red con peque a...

Page 15: ...nchufe est da ado Aseg rese de que los cables no sean expuestos a agua o humedad No toque el cable de red si se ha da ado durante el trabajo Compruebe todos los filtros y juntas antes del encendido y...

Page 16: ...inas o establecimientos de alquiler El producto est dise ado para su uso en zonas secas donde no haya peligro de explosi n Prohibido hacer funcionar el producto en entornos contaminados con amianto Es...

Page 17: ...or rendimiento de purificaci n El nivel 1 sirve para la purificaci n posterior del aire y se puede activar cuando no hay personas en la sala Antes de empezar los trabajos retire la cubierta de la entr...

Page 18: ...con un cepillo seco Limpie la carcasa utilizando nicamente un pa o ligeramente humedecido No utilice limpiadores que contengan silicona ya que podr a afectar a las piezas de pl stico Mantenimiento ADV...

Page 19: ...no est inser tado correctamente Inserte el enchufe de red en la toma de corriente Cable de red o enchufe defectuo sos P ngase en contacto con el Servicio T cnico de Hilti Hay polvo en la salida de air...

Page 20: ...otentiel qui peut entra ner de graves blessures corporelles ou la mort ATTENTION ATTENTION Pour une situation potentiellement dangereuse pouvant entra ner des blessures corporelles ou des d g ts mat r...

Page 21: ...toutes les consignes qui y figurent Toute manipulation ou modification du produit est interdite Utiliser le produit appropri Ne pas utiliser le produit des fins non pr vues mais uniquement conform me...

Page 22: ...ign des sources de chaleur des parties grasses des bords tranchants ou de pi ces du produit en rotation Un c ble endommag ou torsad augmente le risque d un choc lectrique En cas de coupure de courant...

Page 23: ...roximit de gaz inflammables et explosifs Porter des gants de protection lors de travaux avec des mat riaux br lants et de travaux de maintenance sur le produit S assurer que le purificateur d air est...

Page 24: ...aux les usines les magasins les bureaux et les agences de location Le produit est con u pour tre utilis dans des zones s ches et ne pr sentant pas de risques d explosion Le produit ne doit pas tre uti...

Page 25: ...ettoyage maximale Le niveau 1 est destin la purification ult rieure de l air et peut tre activ lorsqu il n y a personne dans la pi ce Avant de travailler retirer le couvercle de l entr e d air 1 S ass...

Page 26: ...n chiffon l g rement humidifi Ne pas utiliser de nettoyants base de silicone ceci pourrait attaquer les pi ces en plastique Entretien AVERTISSEMENT Risque d lectrocution Des r parations inappropri es...

Page 27: ...appareil Brancher la fiche dans la prise Le c ble d alimentation r seau ou le connecteur est d fectueux S adresser au S A V Hilti Il y a de la poussi re dans l air d vacuation Le joint du filtre est...

Page 28: ...24 Fran ais 2297302 2297302...

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ...Hilti registered trademark of Hilti Corp Schaan Pos 3 20211201 2297302 2297302...

Reviews: