background image

*2297302*

2297302

English

5

3.2

Intended use

The product described is an air cleaner for removing fine dust particles from room air and is designed for

the professional application, e.g. for use on construction sites, in hotels, schools, hospitals, factories, stores

and offices, and by rental companies. The product was developed for use in dry rooms where there is no

risk of explosion.

Do not use the product in environments where there is asbestos contamination.

The product is only intended for indoor use.

3.3

Items supplied

Air cleaner, detachable supply cord, pre-filter (3×), main filter (3×), operating instructions

Other system products approved for use with this product can be found at your local

Hilti Store

or at:

www.hilti.group

4

Technical data

4.1

Product properties

For information on rated voltage, rated current, frequency and/or rated input power, refer to the

country-specific rating plate on your product.

AIC 600

Dimensions (L × W × H)

492 mm × 419 mm × 674 mm

(19.4 in × 16.5 in × 26.5 in)

Power source

1-phase

Filter surface area (3 main fil-

ters)

3.1 m²

(33 ft²)

Max. volume flow rate (turbine

data)

1009,4 CFM (476.4 ℓ/s)

Max. vacuum

500 Pa

(0.073 psi)

5

Use of extension cords

Use of extension cords

WARNING

A damaged supply cord presents a hazard!

Do not touch the supply cord or extension cord if it is damaged

while work is in progress. Disconnect the supply cord plug from the power outlet.

Check the appliance's supply cord at regular intervals and replace it if it is damaged.

• Use only extension cords of a type approved for the application and with conductors of adequate gauge

(cross section). The appliance may otherwise suffer a drop in performance and the extension cord may

overheat.

• Regularly check the extension cord for damage.

• Replace damaged extension cords.

Information on recommended minimum conductor cross-sections and cable lengths is accessible via

a link, in the form of a QR code, at the end of this document.

6

Operation

You achieve optimum cleaning power when you operate the product without hoses connected and with the

shutter open. Depending on the conditions and the application, you can connect an intake hose or position

the product directly in a dust-stop partition wall.

The product has 2 air-cleaning stages. In operation, use stage 2 with the higher cleaning power. The stage 1

setting is only for post-cleaning the air. It can be activated when the room is unoccupied.

Summary of Contents for AIC 600

Page 1: ...AIC 600 English 1 Espa ol 8 Fran ais 16...

Page 2: ...1...

Page 3: ...2 3 4...

Page 4: ...AIC 600 en Original operating instructions 1 es Manual de instrucciones original 8 fr Notice d utilisation originale 16...

Page 5: ...at can lead to serious injury or fatality CAUTION CAUTION Draws attention to a potentially dangerous situation that could lead to personal injury or damage to the equipment or other property 1 2 2 Sym...

Page 6: ...tool before use and comply with all the instructions and warnings Do not tamper with or attempt to make alterations to the product Use the right product for the job Do not use the product for purpose...

Page 7: ...from the power outlet Use the power outlet on the product only for the purposes described in the operating instructions Never operate the product when it is dirty or wet Dust especially dust from con...

Page 8: ...been disconnected from the power outlet Do not use the product to filter hot or incandescent fragments or particles Make sure that the temperature of the inducted contaminated air does not exceed 60...

Page 9: ...9 4 CFM 476 4 s Max vacuum 500 Pa 0 073 psi 5 Use of extension cords Use of extension cords WARNING A damaged supply cord presents a hazard Do not touch the supply cord or extension cord if it is dama...

Page 10: ...de filters by pulling the shutter up 6 Switch the tool on 6 2 Replacing pre filters 3 1 Switch the air cleaner off and wait until the turbine runs down to a complete stop 2 Open the pre filter cover 1...

Page 11: ...ilters 8 Transport and storage Transport Do not transport this product with an accessory installed for example the extraction hose Make sure that the equipment is held securely throughout all transpor...

Page 12: ...hilti com manual id 2297302 This link is also to be found at the end of the documentation in the form of a QR code Manual de instrucciones original 1 Informaci n sobre la documentaci n 1 1 Acerca de...

Page 13: ...usuarios profesionales y solo personal autorizado y debidamente formado puede utilizarlos y llevar a cabo su mantenimiento y conservaci n Este personal debe estar especialmente instruido en lo refere...

Page 14: ...baci n o la reparaci n del producto a un servicio t cnico homologado de Hilti No tienda el cable de red bajo una alfombra ni por debajo de muebles u otros aparatos No cubra el cable de red con peque a...

Page 15: ...nchufe est da ado Aseg rese de que los cables no sean expuestos a agua o humedad No toque el cable de red si se ha da ado durante el trabajo Compruebe todos los filtros y juntas antes del encendido y...

Page 16: ...inas o establecimientos de alquiler El producto est dise ado para su uso en zonas secas donde no haya peligro de explosi n Prohibido hacer funcionar el producto en entornos contaminados con amianto Es...

Page 17: ...or rendimiento de purificaci n El nivel 1 sirve para la purificaci n posterior del aire y se puede activar cuando no hay personas en la sala Antes de empezar los trabajos retire la cubierta de la entr...

Page 18: ...con un cepillo seco Limpie la carcasa utilizando nicamente un pa o ligeramente humedecido No utilice limpiadores que contengan silicona ya que podr a afectar a las piezas de pl stico Mantenimiento ADV...

Page 19: ...no est inser tado correctamente Inserte el enchufe de red en la toma de corriente Cable de red o enchufe defectuo sos P ngase en contacto con el Servicio T cnico de Hilti Hay polvo en la salida de air...

Page 20: ...otentiel qui peut entra ner de graves blessures corporelles ou la mort ATTENTION ATTENTION Pour une situation potentiellement dangereuse pouvant entra ner des blessures corporelles ou des d g ts mat r...

Page 21: ...toutes les consignes qui y figurent Toute manipulation ou modification du produit est interdite Utiliser le produit appropri Ne pas utiliser le produit des fins non pr vues mais uniquement conform me...

Page 22: ...ign des sources de chaleur des parties grasses des bords tranchants ou de pi ces du produit en rotation Un c ble endommag ou torsad augmente le risque d un choc lectrique En cas de coupure de courant...

Page 23: ...roximit de gaz inflammables et explosifs Porter des gants de protection lors de travaux avec des mat riaux br lants et de travaux de maintenance sur le produit S assurer que le purificateur d air est...

Page 24: ...aux les usines les magasins les bureaux et les agences de location Le produit est con u pour tre utilis dans des zones s ches et ne pr sentant pas de risques d explosion Le produit ne doit pas tre uti...

Page 25: ...ettoyage maximale Le niveau 1 est destin la purification ult rieure de l air et peut tre activ lorsqu il n y a personne dans la pi ce Avant de travailler retirer le couvercle de l entr e d air 1 S ass...

Page 26: ...n chiffon l g rement humidifi Ne pas utiliser de nettoyants base de silicone ceci pourrait attaquer les pi ces en plastique Entretien AVERTISSEMENT Risque d lectrocution Des r parations inappropri es...

Page 27: ...appareil Brancher la fiche dans la prise Le c ble d alimentation r seau ou le connecteur est d fectueux S adresser au S A V Hilti Il y a de la poussi re dans l air d vacuation Le joint du filtre est...

Page 28: ...24 Fran ais 2297302 2297302...

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ...Hilti registered trademark of Hilti Corp Schaan Pos 3 20211201 2297302 2297302...

Reviews: