Software architecture
16/70
Figure 4: Use case B: Small footprint flash layout example with firmware update area in SQI
flash
Important:
Runtime issues will occur if the
Remanent
or
Management
areas
are accessed while the COM firmware is running from INTFLASH1.
To avoid this, the host application (APP CPU) must handle the
storage and management of remanent data.
Therefore, the firmware file (
*.nxi
) must be configured accordingly
by using the
Tag List Editor
software; i.e. in the
Remanent Data
Responsibility
tag, the
Remanent Data stored by Host
option
must be enabled. (For information about the Tag List Editor, see
section
How to...Use the Tag List Editor
in the document
Getting
started: netX Studio CDT – netX 90 development
,
DOC170504GSxxEN.)
netX 90 | Production guide
DOC190101PG03EN | Revision 3 | English | 2019-07 | Released | Public
© Hilscher 2019