![HIKVISION DS-K1T341C Series User Manual Download Page 132](http://html1.mh-extra.com/html/hikvision/ds-k1t341c-series/ds-k1t341c-series_user-manual_2133908132.webp)
The door can open by inputting the duress code when there is duress. At the same time, the
client can report the duress event.
Super Password
The specific person can open the door by inputting the super password.
Note
The duress code and the super code should be different.
Elevator Control
Steps
1. Click Configuration → Access Control → Elevator Control Parameters .
2. Check Enable Elevator Control.
3. Set the elevator parameters.
Elevator No.
Select an elevator No. for configuration from the drop-down list.
Elevator Controller Type
Select an elevator controller from the drop-down list.
Interface Type
Select a communication type from the drop-down list for elevator communication.
If you select RS-485, make sure you have connected the device to the elevator controller with
RS-485 wire.
If you select Network Interface, enter the elevator controller's IP address, port No., user
name, and password for communication.
Negative Floor Capacity
Set the negative floor number.
Note
●
Up to 4 elevator controllers can be connected to 1 device.
●
Up to 10 negative floors can be added.
●
Make sure the interface types of elevator controllers, which are connected to the same
device, are consistent.
Set RS-485 Parameters
You can set the RS-485 parameters including the peripheral, address, baud rate, etc.
Click Configuration → Access Control → RS-485 Settings .
Check Enable RS-485, and set the parameters.