Set and Execute Hardware Trigger Mode
Steps
1. Click I/O Control Settings → Input → Trigger Mode.
2. Select On as Trigger Mode.
3. Select LineIn 0, LineIn 1 or LineIn 2 as Trigger Source.
4. Set Debounce Time and Line Out Trigger In Polarity according to actual demands.
Note
When selecting Rising Edge or Falling Edge as Line Out Trigger In Polarity, you can set Trigger
Delay. When selecting Level High or Level Low as Line Out Trigger In Polarity, you can set Start
Delay Time and End Delay Time according to actual demands.
Figure 7-12 Set and Execute Hardware Trigger Mode
Set and Execute Counter Trigger Mode
Counter specifies that the trigger source will be generated after the set number of valid signals
appears. For example, if you set the Count Number to 3, the trigger source will be generated after
3 signals appear.
Steps
1. Click I/O Control Settings → Input → Trigger Mode.
2. Select On as Trigger Mode.
3. Select Counter 0 as Trigger Source.
4. Set Trigger Delay, Count Number, Count Source and Line Out Trigger In Polarity according to
actual demands.