background image

 

Copyright © 2019 smart optics Sensortechnik GmbH. All rights reserved. 

– Translation of the original operating instructions – 

 

 

Operating Manual 

Pr

os

th

eti

c S

ca

nn

er

 

 

Vinyl Series 

A product from smart optics Sensortechnik GmbH 

 

 

Summary of Contents for 90334

Page 1: ...ght 2019 smart optics Sensortechnik GmbH All rights reserved Translation of the original operating instructions Operating Manual Prosthetic Scanners Vinyl Series A product from smart optics Sensortechnik GmbH ...

Page 2: ...entation Please send us an e mail to communications smartoptics de If you are looking for a reseller in your area please use the contact form for Sales on our homepage www smartoptics de BRANDS AND TRADEMARKS Windows NET Framework and Visual C are registered trademarks of Microsoft Corporation FlyCapture and UpdatorGUI are registered trademarks of Point Grey Research Inc exocad is a registered tra...

Page 3: ...1 Choosing a workstation 36 5 2 Unpacking the scanner 36 5 3 Connecting the scanner 41 5 4 Opening and closing the scanner 43 6 The object holder system 44 6 1 Overview 44 6 2 Matting the surface with 3D scan spray 45 7 Positioning of a single jaw model 46 7 1 Inserting a jaw model with a Multisplit mounting plate 46 7 2 Inserting a jaw model with an adapter plate 48 7 3 Inserting a jaw model with...

Page 4: ...jects on the flexible object holder 70 12 2 Inserting the object holder 72 12 3 Removing the object holder 73 13 Positioning the calibration model 74 14 Operating principle of the scanner 76 14 1 Operation via touchscreen 77 14 2 Switching between LR and HR mode 79 15 Device maintenance 79 16 Faults and repairs 81 17 Environmentally friendly disposal 82 17 1 Disposal of the packaging 82 17 2 Dispo...

Page 5: ...condyle related otherwise average The fully open Vinyl Open Air model provides a solid basic configuration with the most important modules and it can be expanded when necessary The Vinyl standard model is equipped with all modules and also with a lid allowing closed scanning when necessary The high end model Vinyl High Resolution is the only scanner in the series with a high resolution camera a bl...

Page 6: ... are described in this manual Graphic symbols and highlighting of important information In this manual graphic symbols and text highlights are used to present the information more clearly In this way you may understand the instructions better A triangle on the left indicates a step involving an action A tick on the left tells you what the outcome should be if you have followed one or more steps co...

Page 7: ...ely Variants in operation and functionality which do not apply to this scanner type are marked with this symbol Standard settings specified by the manufacturer are indicated with a steering wheel TIP The word Tip and the information icon are used to highlight tips on operation and information that require your special attention The manufacturer of the product is indicated by the factory symbol Fig...

Page 8: ...names are shown in Courier font Units of measurement and numbers In this manual the numbers are given according to the decimal system with decimal places Units of measurement comply with the legal units in Germany as well as the international system of units SI Further information as well as measurement converters can be found on the Internet Measurement Unit Abbreviation Mass weight Kilogram Gram...

Page 9: ...tional Protection IP 1st digit solids protection 2nd digit fluids protection Temperature Degree Celsius Memory PC Random Access Memory RAM Data volume Megabyte Gigabyte MB GB CAD data format Polygon file format Standard Triangulation Language American Standard Code for Information Interchange Mesh Point Cloud Measurement PLY STL ASCII MSH PCM Picture element Pixel Megapixel Px monitor dpi print Mp...

Page 10: ...ol warns you about possible material damage that might occur if the instructions are not followed correctly CAUTION This combination of signal word and symbol warns you about possible minor injuries that might occur if the instructions are not followed correctly WARNING This combination of signal word and symbol warns you about severe to lethal injuries that might occur if the instructions are not...

Page 11: ... bodies scan bodies screw retained in the model Use as a universal scanner The proper use of the smart optics Vinyl Series scanners is the optical three dimensional measurement of objects with a maximum size of 80 60 85 mm XYZ The maximum weight of the objects must not exceed 0 938 kg The scanners can be used for the production of for example tools jewelry or toys as well as to test the accuracy o...

Page 12: ...t optics scanner require special knowledge for the safe operation of the scanner This knowledge can be acquired by means of the following measures Read and follow these operating instructions in particular the instructions concerning setup commissioning and cleaning of the scanner Participate in an induction or training course Comply with local laws regulations occupational safety and accident pre...

Page 13: ...water moisture Should this however happen at some time disconnect the power plug immediately Dry the affected parts with a soft microfiber cloth Do not work with defective devices or cables under any circumstances Operate electrical equipment only at the recommended operating temperatures Only use the supplied cable or the corresponding spare parts If electrical devices are not used over a longer ...

Page 14: ...t retinal damage or contribute to it White LED light also has a high blue content Users should therefore avoid prolonged visual contact with white or blue LED light The scanner emits white light or blue light with each measurement Close or cover the scanner during operation Wearers of glasses can protect their eyes with glasses with a blue light filter CAUTION Risk of falling due to packaging mate...

Page 15: ...ays grasp it by the bottom corners never by the lid CAUTION Risk of injury due to the lid or the mechanical parts of the scanner You can get crushed by the lid or the mechanical parts of the scanner Always hold the lid by its handle to open or close it If you act sideways and move the lid you will crush your fingers between the lid and the housing Lift the lid gently Otherwise it will fall down ag...

Page 16: ...art Protection against material damages Despite the protective measures included in the design some residual risks that might lead to material damages loss of data or damage to devices cannot be excluded In this section you will learn what measures can be taken against material damages NOTE Damage to optical and electronic components due to touching humidity dirt and cleaning The optical and elect...

Page 17: ...rasp it by the bottom corners never by the lid nor the front upper corners During transport place a protective film over the lid so that it cannot open NOTE Damage to surfaces due to unsuitable cleaning agents Paper towels coarse cotton cloth detergents polishing paste etc leave scratches on the sensitive surfaces Only use the recommended materials for cleaning NOTE Material damages due to moistur...

Page 18: ...n protection NOTE Measuring errors due to reflections on the measured object Strong extraneous light leads to unwanted reflections on the measured object This affects the accuracy of the measurements Select a workplace away from a window or not affected by high levels of artificial lighting If no other workplace is available scan with the lid closed If you are using Vinyl Open Air cover the openin...

Page 19: ...ation Only use the calibration model if it is in perfect condition NOTE Damage to the scanner and the models due to missing or incorrect fastening Due to the motion of the axes inside the scanner unsecured or incorrectly secured models will fall down during the scanning process Do not place any objects on top of or inside the scanner Never place unfastened models inside the scanner Only use the in...

Page 20: ...nside the scanner when the software asks you to do so Always place an articulator with the front side first inside the scanner Always place an articulator with all legs resting on the system plate Always leave the lid open except in the case of Vinyl Open Air Remove an articulator immediately when the software asks you to do so However should an articulator still fall down turn off the scanner imm...

Page 21: ... way the calibration procedure fails measuring errors occur despite performing all work steps the software displays an error message Follow the instruction in an error message Check the connections If applicable replace the USB slots End the software switch off the scanner and the PC and restart the system Check whether the software is installed correctly Check the calibration data Follow the inst...

Page 22: ...o the calibrated optical system This must never be touched or cleaned as it could be damaged in the process Other CE label The CE label on the type plate documents that the European directives that are applicable to the device were complied with at the time of issue of the CE certificate EMC labelling The electromagnetic compatibility of the device was checked for compliance with the limit values ...

Page 23: ... for a USB connection also for a camera connection Protective grounding Symbol for connection to an external conductor to protect against electric shock in the event of a fault or connection of protective grounding mass On Off switch Symbol for a switch to turn the device on and off ...

Page 24: ...ple Tray impression holder 2 packs of adhesive pads extra strong 1 calibration model 1 data carrier Accessory case 1 object holder with knurled screw 1 object holder flexible with large plate 1 multiDie adapter 1 Triple Tray impression holder 2 packs of adhesive pads extra strong 1 calibration model 1 data carrier Accessory box 1 object holder with knurled screw 1 calibration model 1 data carrier ...

Page 25: ...th the modules secondDie Monochrome texture Scan Color texture Scan Universal mode Manuals PDF Scanner Operating Manual dental Scan Installation Manual User Manual Manuals PDF Scanner operating manual dental Scan Installation Manual User Manual Manuals PDF Scanner Operating Manual dental Scan Installation Manual User Manual Additional modules available for purchase optional accessories Packaging T...

Page 26: ... accessories from your reseller Item number Item name Description 90404 PC Dell Precision 3630 CTO High performance computer with preinstalled software 90073 3D calibration model Replacement or additional item 90082 Object holder with knurled screw Replacement or additional item 90350 multiDie adapter Replacement or additional item 90242 Occlusion clamp Aid for the occlusion of non articulated jaw...

Page 27: ...ls suitable for KaVo PROTAR Additional item 144042 Handmade dust cover Additional item For safety reasons please use only the replacement or additional items mentioned here For parts that are not listed as replacement items e g cables please replace them with commercially available products with the same technical specifications PCs must meet the technical specifications Activate the optional modu...

Page 28: ...t optics as accessories for the scanner All conventional articulators can be used for vestibular scans with articulated occlusion models Condyle related measurements are possible with the articulators of the following manufacturers AMANN GIRRBACH Artex Baumann Dental Artist arTO SAM AXIOSPLIT GAMMA Reference Whip Mix Denar KaVo PROTAR Other articulators can be used for mean value measurements ...

Page 29: ... Device components Page 29 4 Device components 4 1 Front view 1 HR label only for Vinyl High Resolution 2 Lid not included for Vinyl Open Air 3 Device name 4 Handle black or silver matte depending on the model series 5 Touchscreen CAPTION 2 3 4 5 1 ...

Page 30: ...ouchscreen 1 Starting status logo Operation from the PC possible 2 Hibernation screen saver Operation from the PC possible 3 Operating status Start button and process display Start button Operation from the device possible Process display The device is working no user action possible CAPTION 1 2 3 ...

Page 31: ...amera and 3D sensor 2 Swivel axis electromotive lateral movement 0 45 Z axis electromotive up and downwards movement 0 30 mm 3 Guide rails for the lid not present in the Vinyl Open Air variant 4 Rotary axis electromotive rotation up to 315 System plate with Adesso Multisplit base plate CAPTION 1 2 3 4 3 ...

Page 32: ...at for the placement of articulators 2 Adesso Multisplit base plate for mounting object holders adapter plates and Multisplit mounting plates Detailed view of camera sensor and LED 1 LED white light or blue light only for Vinyl High Resolution 2 Optical system camera and sensor high resolution for Vinyl High Resolution CAPTION CAPTION 1 2 2 1 ...

Page 33: ...inyl High Resolution 1 Status LED on the swivel axis Purple Hibernation equivalent to the logo or screen saver on the touchscreen Green Operation corresponds to the start button and the process display on the touchscreen 4 3 Views of the accessories standard scope of delivery Accessory case with foam insert CAPTION 1 ...

Page 34: ...er with knurled screw Flexible object holder with large plate fixing with adhesive pads multiDie adapter fixing with adhesive pads Triple Tray Impression Holder Adhesive glue pads extra strong Example image Calibration model Example image Power cable USB cable Data carrier Example image ...

Page 35: ...grounding 3 USB connection for device control and camera 4 Mains connection with fuse The type plate with technical information such as serial number of the device place and date of manufacture is located on the rear The serial number of the 3D sensor is given on a separate label CAPTION Type plate 1 3 2 4 3D sensor serial No SO 20254 00 17 022 ...

Page 36: ...ated Ensure that there are enough and sufficiently fused mains sockets for all the devices After consultation with an electrician you can use an approved extension cable a multiple power socket and a socket adapter additional electrical devices not included in the scope of delivery 5 2 Unpacking the scanner The scanner is delivered in a foldable wooden box The wooden box is equipped with an impact...

Page 37: ...e To unpack you needed a flat tip screwdriver and combination pliers Bend back the metal tabs at the top and bottom of the wooden box For this purpose carefully press the screwdriver between the tab and the wood until a gap is created Grasp the tab with the pliers Bend the tab about 180 those at the top upwards those at the bottom downwards When all metal tabs are in a vertical position they will ...

Page 38: ...ite corners Carrying by two persons recommended TIP Due to the dimensions and weight smart optics recommends carrying by two persons Never hold it by the lid In the case of Vinyl Open Air never hold it by the front upper corners because sensitive technical components are placed there The protective foil prevents incorrect gripping or unintentional opening of the lid ...

Page 39: ...anner simultaneously When carrying incline the scanner slightly backwards In this position the lid remains secured Carrying by one person not recommended Position yourself behind the scanner Grasp with one hand on the side and as far forward as possible under the scanner Lift the scanner so that it is slightly inclined backwards when carrying In this position the lid remains secured Position of pe...

Page 40: ...lation Remove the protective foil If necessary take the accessory box out of the base insert Immediately check the scanner and the accessories for completeness and any visible damage If the scope of delivery is not complete or if one of the supplied parts shows visible damage inform your reseller immediately Follow the instructions provided by the reseller before continuing with the setup Chapter ...

Page 41: ... B plug of the USB cable to the USB port of the scanner Connect the device plug of the power cable to the corresponding mains socket on the scanner Connect the mains plug of the power cable to the mains It is not necessary to use an adapter to adjust the voltage as an AC DC device is integrated in the scanner Connect the flat type A plug of the USB cable to a free USB port of the PC Observe the sa...

Page 42: ...age 42 The scanner is operational Switch on the scanner using the power switch The power switch is in position I The touchscreen displays the starting status logo Install dental Scan now You will find comprehensive information in the dental Scan installation manual dental Scan installation ...

Page 43: ...ially during periods of inactivity to protect sensitive components If you are using the Vinyl Open Air model you can cover the opening when necessary e g with light tight foil Hold the handle at the lower edge of the lid Lift the lid gently up to the stop Release the lid in this position The lid will stay in a vertical position without being fastened To close the lid grip the handle Gently move th...

Page 44: ...ws you to securely fasten and insert jaw models partial models tooth stump models Triple Tray impressions and occlusion models 1 Object holder in this case the model with knurled screw for single jaw models 2 Base plate with non slip rubber mat and Multisplit base for object holder adapter plates and Multisplit mounting plates Observe the safety instructions Chapter 2 CAPTION 1 2 ...

Page 45: ...ommends that only products with extra fine grain size and suitability for dental technology be used for example the scan spray offered as part of the accessories Follow the instructions of the manufacturer regarding application safety and material compatibility If the 3D scan spray has to be sprayed in the work area close the scanner or cover it previously This way you protects the sensitive optic...

Page 46: ...r 7 1 Inserting a jaw model with a Multisplit mounting plate No additional fastening is required for jaw models plastered on a Multisplit mounting plate You can place the Multisplit mounting plate directly on the Multisplit base plate of the scanner This option exists for the articulator systems AMANN GIRRBACH Artex and Baumann Dental Artist arTO Plaster the jaw model onto the Multisplit mounting ...

Page 47: ...plit mounting plate fit into the recesses of the Multisplit base plate The Multisplit mounting plate will adhere to the magnet of the Multisplit base plate The Multisplit mounting plate fits correctly when the plates are exactly congruent Additional securing of the plastered jaw model is not necessary ...

Page 48: ...ailable as optional accessories for the following articulator systems SAM AXIOSPLIT GAMMA Reference Whip Mix Denar KaVo PROTAR No adapter plates are required for AMANN GIRRBACH Artex and Baumann Dental Artist arTO Top in this case SAM AXIOSPLIT Bottom in this case SAM AXIOSPLIT The mounting plates of the corresponding articulator fit the top of the adapter plate The underside fits to the Multispli...

Page 49: ...mounting plate will adhere to the magnet of the adapter plate The mounting plate fits correctly when the plates coincide exactly The magnetic adhesive disk in the adapter plates for SAM AXIOSPLIT is retained with a fixating screw Ensure that this is tightened firmly Additional securing of the plastered jaw model is not necessary Inserting an adapter plate Hold the adapter plate from the side of th...

Page 50: ...r plate can be shifted easily If this is the case correct the fit until the adapter plate fits securely Removing the adapter plate Hold the adapter plate on two sides if necessary use both hands not the mounting plate Carefully pull the adapter plate upwards A certain amount of force is required due to the magnetic attraction The adapter plate is released from the Multisplit base plate ...

Page 51: ...older with knurled screw Flexible object holder The flexible object holder for Vinyl Open Air is available as an optional accessory from your reseller It is included in the scope of delivery for Vinyl and Vinyl High Resolution Service position CAPTION 1 Rear 2 Front 3 Floating stop 4 Hook 5 Threaded pins 6 Knurled screw with clockwise thread 7 Adesso Split plastic plate with adhesive disk CAPTION ...

Page 52: ...n of the knurled screw Press the jaw model gently against the threaded pins Tighten the knurled screw The jaw model is placed correctly if it is flush with the floating stop and the threaded pins Flexible object holder Jaw models upper or lower jaw can be securely fastened on the flexible object holder with the big plate To fasten them you require adhesive glue pads Two packs of adhesive pads are ...

Page 53: ...p Should the jaw model slip use additional adhesive pads Inserting the object holders The described procedure is the same for both object holders Hold the object holder from the side Place the object holder with the front side or the knurled screw facing forwards inside the scanner The protrusions Ovals on the underside of the object holder engage with the recesses of the Multisplit base plate The...

Page 54: ...ue to the magnetic attraction The object holder is released from the Multisplit base plate TIP Upon removal the rotary axis may be moved unintentionally For this situation dental Scan features a function to drive the axes back into the service position 7 4 Fastening gingiva squeeze bites scanbodies or wax ups To scan gingiva squeeze bites scanbodies or wax ups fasten the small prosthetic parts to ...

Page 55: ...th and approx 8 5 cm diameter Alternatively you can use a crossed band The length and strength of the rubber band varies depending on the jaw model For this reason always keep several different rubber bands available Rubber bands are not included in the optional scanner accessories For safety reasons use only new robust rubber bands and replace these regularly Place the upper jaw model on the lowe...

Page 56: ...the jaw model Guide one end each at the front and rear around one of the hooks on the side of the object holder If you are using a crossed band you can only secure the jaw models to the object holder in occlusion Place the crossed band around the jaw models in occlusion such that one crossed part is on the top and one on the bottom and that the two partial bands are stretched on the side Secure th...

Page 57: ...btained from your reseller Overview Occlusion clamp without object holder Occlusion clamp with fastened object holder Fastening Fasten first the lower jaw model to the object holder with the knurled screw Place the upper jaw model on the lower jaw model in occlusion Loosen the ball knob 3 as much as necessary to allow the pressure fitting to be moved forwards and backwards Fasten the occlusion cla...

Page 58: ...he upper jaw model Loosen the locking screw 1 until the fastening rod 2 of the pressure fitting can be moved up and down Hold the ball knob and press the upper jaw model onto the lower jaw model Carefully tighten the screw 1 and the ball knob 3 until the occlusion model can no longer be moved The occlusion model is clamped Now place the object holder inside the scanner as usual ...

Page 59: ...ries inside the scanner for vestibular scans Condyle related measuring is possible with the following articulators AMANN GIRRBACH Artex without adapter plate Baumann Dental Artist arTO without adapter plate SAM AXIOSPLIT GAMMA Reference Whip Mix Denar KaVo PROTAR Articulators are available at specialist dealers but not from smart optics as an accessory for the scanner 9 1 Positioning of an occlusa...

Page 60: ...n is it ensured that the motion of the axes is minimal during the ensuing scanning procedure The system plate of the scanner is driven into the horizontal service position If this is not the case dental Scan features a function allowing to drive to this position Grasp the articulator by the rear struts with both hands Place an articulator with the front side forward inside the scanner The front si...

Page 61: ...ening is necessary TIP Always leave the lid open during an articulator scan Removing the articulator Wait until the software reports the end of the scanning procedure Remove the articulator as soon as the software asks you to do so Grasp the articulator as before by the rear struts Lift the articulator horizontally out of the scanner Now you can proceed with the workflow in the software TIP Upon r...

Page 62: ... Overview Numbering of the slots Fastening tooth stump models To ensure that the tooth stump models sit firmly on the multiDie adapter you require the adhesive pads as fixing material Two packs of adhesive pads are included in the scope of delivery As replacement you can use commercially available adhesive glue pads These should be extra strong and removable not coloring nor hardening Fill all slo...

Page 63: ...apter in other words insert the metal pins as deep as possible into the glue material they remain in their position when the multiDie adapter is rotated or tilted It is of advantage but not a precondition to insert the tooth stump models such that the buccal side faces outwards Inserting the Triple Tray impression holder Hold the multiDie adapter from the side Place the multiDie adapter inside the...

Page 64: ... adapter fits securely Removing the Triple Tray impression holder Hold the multiDie adapter from the side if necessary use both hands Carefully pull the Triple Tray impression holder upwards A certain amount of force is required due to the magnetic attraction The Triple Tray impression holder is released from the Multisplit base plate TIP Upon removal the rotary axis may be moved unintentionally F...

Page 65: ...on holder for Vinyl Open Air is available as an optional accessory from your reseller It is included in the scope of delivery for Vinyl and Vinyl High Resolution Overview Fastening a Triple Tray impression scan A Triple Tray impression tray can be clamped quite easily in the Triple Tray impression holder Press the clamp on the broad side and keep it pressed CAPTION 1 Upper part 2 Lower part 3 Rear...

Page 66: ...ening The Triple Tray impression is fastened correctly if it is clamped it is positioned parallel to the lower part of the Triple Tray impression holder the impression to be scanned faces upwards Turning a Triple Tray impression To scan the other side of the Triple Tray impression turn the upper part without releasing the impression from the clamp Separate the upper part from the lower part applyi...

Page 67: ...Inserting the Triple Tray impression holder Hold the Triple Tray impression holder from the rear Place the Triple Tray impression holder with the impression facing forwards inside the scanner The Triple Tray impression holder will adhere to the magnet of the Multisplit base plate The protrusions Ovals on the underside of the plastic plate engage with the recesses of the Multisplit base plate The T...

Page 68: ...y impression holder Hold the Triple Tray impression holder by the lower part if necessary use both hands Carefully pull the Triple Tray impression holder upwards A certain amount of force is required due to the magnetic attraction The Triple Tray impression holder is released from the Multisplit base plate TIP Upon removal the rotary axis may be moved unintentionally For this situation dental Scan...

Page 69: ... tools jewelry or toys with a maximum size of 80 60 85 mm XYZ and a maximum weight of 0 938 kg can be scanned The flexible object holder for Vinyl Open Air is available as an optional accessory from your reseller It is included in the scope of delivery for Vinyl and Vinyl High Resolution Please note that the standard scope of delivery of Vinyl and Vinyl High Resolution includes one multiDie adapte...

Page 70: ...ending on the shape of the object it may be useful to choose a different fastening for the second side 12 1 Fastening objects on the flexible object holder Objects can be fastened securely on the flexible object holder with the big plate TIP Try out the best way to fasten an object Test the stability of the fastening outside the scanner using sideways and rotational movements to determine which ob...

Page 71: ...r magnetic tape available as office supplies The adhesive effect depends on the individual magnetization of the object and the inserted magnetic plates Non magnetic objects Adhesive glue pads are necessary to fasten non magnetic objects Two packs of adhesive pads are included in the scope of delivery You can purchase replacements from office suppliers if required Cover the topside of the plate wit...

Page 72: ...object does slip use more adhesive pads or alternatively test another object holder 12 2 Inserting the object holder The described procedure is the same for all object holders Hold the object holder from the side Place an object holder with the front side forward inside the scanner The protrusions Ovals on the underside of the object holder engage with the recesses of the Multisplit base plate The...

Page 73: ... fasten an object to the object holder you should always remove the object holder from the scanner Hold the adapter plate on both sides if necessary use both hands Carefully pull the object holder upwards A certain amount of force is required due to the magnetic attraction The object holder is released from the Multisplit base plate TIP Upon removal the rotary axis may be moved unintentionally For...

Page 74: ...ivery Each calibration model is measured industrially and assigned these measurements TIP If your calibration model is damaged and you are unsure whether this model can be used your reseller will be pleased to advise you and provide you with a replacement if necessary It is recommended to have the calibration model always at hand during operation Overview CAPTION 1 Top 2 Bottom 3 Depressions 4 Mea...

Page 75: ...of the calibration model on the object holder Press the depressions of the calibration model slightly against the threaded pins of the object holder Tighten the knurled screw The calibration model is placed correctly when it is flush both at the front and the rear The impression with the measured values faces the floating stop Insert the object holder When doing it observe the software s messages ...

Page 76: ...ental Scan user manual The most important components of the scanner are the 3D sensor and a positioning mechanism The positioning mechanism in the interior of the scanner consist of a rotary and swivel axis driven by an electric motor 4 as well as an automatic z axis 2 The freely rotating Multisplit base plate 3 positions the object to be measured with regard to the 3D sensor 1 which is located ab...

Page 77: ...s The camera records the striped pattern With the aid of several camera images taken from different angles dental Scan calculates a 3 dimensional image of the object 14 1 Operation via touchscreen The scanner is equipped with a touchscreen which allows you to start scanning processes Operation via touchscreen is an alternative to a mouse click in the software You can also control the scanner exclu...

Page 78: ... start button appears on the touchscreen Follow the instructions given by the software Press the button to start The scanning process starts While scanning the animated red circle will be displayed and when the procedure has finished the company logo After prolonged inactivity the screen saver is activated automatically Messages ...

Page 79: ...ettings of dental Scan However you can switch between the modes for each project and every single scan The exact procedure is described in the dental Scan user manual 15 Device maintenance The scanner is a delicate and sensitive optical device To ensure trouble free operation of the scanner it is necessary to regularly follow the correct care measures Further maintenance measures by the user are n...

Page 80: ...sly suitable for high gloss surfaces The material must be soft smooth lint free and anti static Always dampen the cleaning cloth with a glass cleaner Never clean sensitive surfaces with abrasives polishing pastes or rough cloths Clean the surfaces as well as the object holder the system plate and the axes with the moistened cleaning cloth Clean the touchscreen without applying pressure Coarse dirt...

Page 81: ...homepage www smartoptics de Improper repairs can cause the scanner to stop working perfectly smart optics accepts no liability for damages caused by improper repairs Please note that in this case your warranty claim will also become void Serial numbers If you have questions or complaints relating to your device please have the serial number of your Scanner and the serial number of the 3D sensor at...

Page 82: ...r reseller for disposal in Germany However smart optics recommends that you keep the packaging in case you need it to transport the scanner or to send it back in the event of warranty claims 17 2 Disposal of the device The devices marked with this symbol are subject to European Directive 2002 96 EC for WEEE Waste Electrical and Electronic Equipment WEEE registration number of smart optics DE478932...

Page 83: ...mum load bearing capacity Universal Mode 0 938 kg 0 938 kg 0 938 kg Axes 1 Rotary axis 1 Swivel axis 1 Z axis 1 Rotary axis 1 Swivel axis 1 Z axis 1 Rotary axis 1 Swivel axis 1 Z axis Material Metal plastic ABS HB PMMA Metal plastic ABS HB PMMA Metal plastic ABS HB PMMA Housing color black white highly glossy black white highly glossy Black white highly glossy Handle and display frame color silver...

Page 84: ...ration 18 C 30 C 18 C 30 C 18 C 30 C Storage 5 C 50 C 5 C 50 C 5 C 50 C MEASUREMENT High resolution camera No No Yes HR Mode resolution LR Mode resolution Camera 1 3 Mpx Point Grey 1 3 Mpx Point Grey 2 8 Mpx 1 4 Mpx Point Grey 3D measuring technology Stripe light triangulation with white light LED Stripe light triangulation with white light LED Stripe light triangulation with blue light LED Measur...

Page 85: ...EMENTS PC CAD SOFTWARE AVAILABLE EXTRA PC Minimum CPU i3 with 4 3 6 GHz RAM 16 GB Port USB 3 0 HDD 40 100 GB Graphics card RAM 1 GB CPU i3 with 4 3 6 GHz RAM 16 GB Port USB 3 0 HDD 40 100 GB Graphics card RAM 1 GB CPU i5 with 4 3 8 GHz RAM 32 GB Port USB 3 0 HDD 100 250 GB Graphics card RAM 6 MB PC recommended CPU i7 with 6 4 7 GHz RAM 32 GB Port USB 3 0 HDD 100 250 GB Graphics card RAM 6 MB CPU i...

Page 86: ...Vinyl Series Operation Document Version 01 2019 Declaration of CE conformity Page 86 19 Declaration of CE conformity ...

Page 87: ...anner Workstation Table s load bearing capacity 46 kg Scanner s space requirements B H D mm 455 430 420 455 660 470 PC with recommended configuration CPU i7 with 6 4 7 GHz RAM 32 GB Port USB 3 0 HDD 100 250 GB Graphics card 6 MB RAM Windows 10 64 Bit Unpacking Tools required Observe the display and the instructions Follow the description Keep the packaging Chapter 5 Step 1 Step 2 Step 3 ...

Page 88: ...device under its edges Tilt the device slightly backwards Connection Connect the power cable Connect the USB cable Switch on rear Installation Copy the data carrier locally dental Scan exe Install the software Start the software Load the calibration data Calibrate Fasten the model Insert 1 and 2 Ready to scan Step 4 Step 5 Step 9 dental Scan installation Use of dental Scan ...

Page 89: ...trological term A alignment of the scanner to the values of an industrially calibrated model B alignment of the motion axes with regard to the individual calibration data Calibration model Industrially measured model which is used for calibrating the scanner Height alignment Positioning of the model in the measuring field of the 3D sensor with the aid of the z axis HR mode High resolution scanning...

Page 90: ... of the motion axes of the scanner The base can be rotated Free rotation of the base allows full circumferential positioning in front of the camera Stripe light A striped pattern which is projected on the model to measure the surface three dimensionally Swivel axis One of the motion axes of the scanner The swivel axis moves sidewards so that the model is positioned in front of the camera at differ...

Page 91: ... model 74 Case accessories 36 Caution convention 10 CE Conformity 86 Labelling 22 Clamp Occlusion 57 Triple Tray 65 Clasp forceps 57 Cleaning 80 Cleaning agents 80 Code of response 21 Colors Status LED 33 Colors material 11 Comma Notation of numbers 8 Connections Mains 35 41 USB 35 41 Conventions 6 Cover 43 D Data carrier 24 Defect Calibration model 74 Device 21 81 Denominations Accessories 33 Ada...

Page 92: ...ith occlusion clamp 57 Fasten with rubber band 55 Fastened inside the scanner 46 48 52 55 60 Fastened with an articulator 59 With gingiva 54 With scanbody 54 With squeeze bite 54 With wax up 54 K kg technical data 83 kg unit of measurement 8 Knurled screw 52 57 74 L LED white blue 76 Lifting scanner 38 39 Lifting points 38 39 Low Voltage Directive 86 LR and HR mode 79 M Machine Directive 86 Mains ...

Page 93: ...32 44 multiDie Adapter 62 Object holder 51 Occlusion clamp 57 Rear view 35 System plate 45 Touchscreen 30 Triple Tray impression holder 65 PC Scope of delivery Optional 26 PC technical data 85 PCM data format 9 PLY data format 9 Positioning Calibration model 74 Objects Universal 69 Occlusion model 55 59 Single jaw model 46 Tooth stump individual tooth 62 Triple Tray impression 65 Positioning items...

Page 94: ...ng 12 Triangle symbol 6 Triple Tray Clamp 65 Insert remove 67 68 Scope of delivery 24 Triple Tray impression scan 65 Type plate 35 81 U Units of measurement International System of Units 8 Universal Mode 69 70 Unpacking 36 USB cable 24 Use as intended 11 V V Technical specifications 84 Vacuuming 80 Vestibular scan occlusion 55 59 Vinyl High Resolution 79 W Warning convention 10 Warranty 81 Watt te...

Page 95: ...Manufacturer smart optics Sensortechnik GmbH Lise Meitner Allee 10 D 44801 Bochum Germany www smartoptics de ID SO 20900 OMBA 90334 90351 90400 EN ...