A1
Measurement Principles
⚝ᒁ
4
3
2
1
7
6
5
10
9
8
1. Insulation resistance measurement
The measurement target’s insulation resistance Rx is
calculated by applying a voltage V to the target, measuring
the leak current I that flows to the target as a result, and
dividing the voltage V by the leak current I.
2. Low resistance measurement
The measurement target’s resistance Rx is calculated by
applying a current I to the measurement target, measuring
the voltage V that occurs between the measurement
terminals as a result, and dividing the voltage V by the
current I.
3. PV
:
measurement
The measurement target’s insulation resistance Rx is
calculated by applying a voltage V to the target, measuring
the leak current I that flows to the target as a result, and
dividing the voltage V by the leak current I.
(Voltage and current generated by the object to be measured
is subtracted.)
Appendix
Measurement Principles
IR4051 IR4052
IR4053
www.
.com
1.800.561.8187