38
2.7 Voltage Measurement
Ex. When measuring the voltage between circuit and ground
1.
Use the rotary selector to select the V function.
2.
Connect the black test lead to the ground side of the
object being measured.
3.
Connect the red test lead to the line side of the breaker.
4.
Read the value after the indicator has stabilized.
1
2
3
4
LINE
EARTH
Caution:
MEASURE
key.
Do not press the
Source
(primary side)
Load
(secondary side)
Always connect the test lead
to the secondary side of the
breaker.
• During measuring, do not selector over to the other
function.
• For waveforms other than sine waves, some errors
may occur.