– remove the lamp and replace it with one resistant to high temperature (300 °C), having the following characteristics:
Voltage:
220/240 V ~ 50-60 Hz
Power:
25 W
Connection:
G9 for halogen bulb
.
Note
: It is advisable not to touch the lamp with hands; use a cloth or a piece of absorbent paper.
Assistance
In case of any operation problems, contact a Highland After-Sales Service Centre
(refer to the enclosed list).
Never resort to unauthorised technicians.
Specify:
– type of fault;
– appliance model (Art.);
– serial number (S.N.).
This information is given on the appliance dataplate, on the warranty certificate.
Installation (Fig. 4)
Important:
Installation must comply with the current standards and regulations. It must be only be carried out by
specialised and licensed personnel.
Cabinet requirements
For fitted units, the components (plastic materials and veneered wood) must be assembled with heat-resistant adhesives
(max. 100 °C): unsuitable materials and adhesives can result in warping and ungluing. The cabinet must allow sufficient
room for the electrical connections. The cabinet in which the oven in fitted must be strong enough to take the weight of
the equipment.
The oven must be securely fitted in the recess. The oven can be installed in a column unit or under the top of a modular
unit, provided sufficient ventilation is guaranteed (see Fig. 5 depending on the model).
Installation instructions
Fit the appliance in the compartment; fix the oven to the cabinet with the 4 screws and the 4 bushings provided, using
the holes prepared in the side panels (Fig. 7a).
Note: (applies to all models) If the oven is to be fitted under a cooktop, firstly turn the top connection (R)
to the right or left so that the oven fits properly (Fig. 7b).
Electrical connection
The Highland oven is supplied with a three-core power cable with free terminals.
If the oven is permanently connected to the power supply install a device that ensures disconnection from the power
supply, with a contact opening distance enabling complete disconnection in category III overvoltage conditions. Make sure:
a) the plug and socket are suitable for a 16 A current;
b) both can be easily reached and are positioned so that no live part is accessible when
inserting or removing the plug;
c) the plug can be easily inserted;
d) the oven does not rest against the plug when installed in the cabinet;
e) the terminals of two appliances are not connected to the same plug;
f) a 3 x 1.5 mm
2
cable type H05VV-F is used when replacing the power cable;
g) the connection polarities of the free terminals are respected
(Brown=Line Blue=Neutral Yellow/Green=Earth).
NB:
Make sure the characteristics of the household electrical system (voltage, maximum power and current)
are compatible with those of your Highland oven.
NB:
If the power cable is damaged, it must be replaced by the manufacturer or its after-sales service or else by a person
with similar qualifications, in order to avoid any risks.
BLUE
YELLOW-GREEN
BROWN