background image

Code

Default

Value

Unit

HC

H

_

L5

No

Function

H5

45

PE

1

Min

CR

00

d

2

1. The sensor should be set up correctly
2. Enlarge the expanded wire size if any.
3. Make sure the wires sealed is good.
4. Change the sensor.

1.Check if the sensor has accurately measured the
temperature or not.
2.Change contactor.

1. Check to see if the connection of sensor and
coupling are good.

1. The sensor is not correctly installed to
detect the correct temperature.
2. Contactor fails.

Solution

1.Check power supply and change fuse.
2.Check if the input voltage is right or change the
thermostat with our distributor.

1.Reset the desired temperature.
2.Check the reasons for overheating and less
pressure.
3.After the trouble is solved, restart to work.

1. Sparate sensor wire with power cables
2. Change shielded lines
3. Check if the terminal is tight.

Causes

1. Check if the power is open or the
thermostat failture.

1.The setting temperature is higher than
the present temperature.
2.The flow switch is open circuit because
of low water pressure.

1. The sensor is interfered;
2. Poor wiring;
3. Wire damage.

1.The sensor is opened or shorted circuit.

1. The installation position of the sensor is
not correct;
2. The sensor's wiring is too long
3. The wire connected poor;
4. The sensor is damaged.

"EI"  is displayed

Big tolorance between
current temperature and
displayed.

Machine does not stop
when reach the desired
temperature.

Displaying but machine
doesn't work

Display the temperature
is unstable or there exists
misplay

Temperature Return
Difference

1~15

Failure

No display when power is
on.

Alarm on high limit
Temperature

 +1

 to 80

Delayed Time

0~5

Temperature Correction

-15~15

Function

Setting Range

Heating/Cooling

H/C

Alarm on low limit
Temperature

 -1 to -45

Hold "set", then press 

or 

 

simultaneously. Choose 

HC, 

represents Warm Mode, 

represent Cold Mode. 

 Hold "set", then press 

or 

 

simultaneously. Choose lowest 
temperature limits: Temperature 
c1

to 80

 

 Hold "set", then press 

or 

 

simultaneously. Choose highest 
temperature limits: Temperature 
c1

to 80

 

 Hold "set", then press 

or 

 

simultaneously to set delayed 
star time from 0 to 5 minutes. 
 

 Hold "set", then press 

or 

simultaneously. Choose 

temperature correction: -15

 

to 

15

 

 Hold "set", then press 

or 

simultaneously. Choose return 

difference: 1

 to 15

 

 

 Error symbol: when the sensor in 
opened or shorted circuit. Code 

EI

 

will be displayed. 

Brief on Operation 

Trouble Shooting  

Note:  
Cooling Capabilities are Not Provided with this equipment.  

Summary of Contents for Hidro-H11

Page 1: ...SPA HEATER USER MANUAL ...

Page 2: ...HIPMENT AND HANDLING WARNING Only qualified personnel should install and maintain this equipment Unauthorized alteration or improper maintenance of this unit may release the manufacturer from any warranty claims The installation must be in accordance with the instructions in this manual and applicable local plumbing and electrical codes ...

Page 3: ...60Hz Hidro HS9 9KW 220V 50Hz or 60Hz Hidro HS11 11KW 380V 50Hz or 60Hz Hidro HS15 15KW 380V 50Hz or 60Hz Hidro HS18 18KW 380V 50Hz or 60Hz Hidro HS18Pro 18KW 380V 50Hz or 60Hz Hidro HS24Pro 24KW 380V 50Hz or 60Hz Hidro HS32Pro 32KW 380V 50Hz or 60Hz Hidro HS36Pro 36KW 380V 50Hz or 60Hz Heaters with manual thermostat Heaters with Digital Thermostat Control SPA Heater Model List SPA Water Heater whe...

Page 4: ...e their use may lead to unconsciousness with the possibility of drowning E Obese persons and persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a pool or tub F Persons using medication should consult a physician before using a pool or tub since some medication may induce drowsiness while other m...

Page 5: ...iet do not expel exhaust fumes and may be conveniently located in a shed or basement It should be securely mounted to a smooth flat surface Normal positioning of the pool heater should be in close proximity to the pool filtration Select a location conveniently close to incoming electrical service and where excessively long piping runs are not required Leave minimum clearance of 9 inches 230mm on t...

Page 6: ...lectrical supply B CHECK ELECTRICAL CONNECTIONS TO ALL COMPONENTS within the heater for tightness These can become loose during shipment and handling C Check components for any moisture rust or dust which may have accumulated during shipping and clean or dry where necessary D Do not connect the pool heater to or operate at a voltage other than the voltage rated on the nameplate E The power supply ...

Page 7: ...Wiring Diagram Single Phase Models Wiring Diagram Three Phase Models Figure 2 L1 L2 Ground Ground L1 L2 L3 N Single Phase Models Three Phase Models Wiring Status for Testing ...

Page 8: ...heat the HEAT light will be illuminated For heaters equipped with a digital thermostat The digital thermostat control which measures the temperature of the water as it enters the heater has a MENU button up and down adjustment buttons and an LED display The desired water temperature set point is controllable between 40 F and 100 F 5 and 40 The set point may different from the actual water temperat...

Page 9: ...e installation position of the sensor is not correct 2 The sensor s wiring is too long 3 The wire connected poor 4 The sensor is damaged EI is displayed Big tolorance between current temperature and displayed Machine does not stop when reach the desired temperature Displaying but machine doesn t work Display the temperature is unstable or there exists misplay Temperature Return Difference 1 15 Fai...

Page 10: ...ing down the pool for any length of time shut off the power at the main disconnect switch and drain the water from the system Water must not be allowed to freeze in the heater as this will cause severe damage Annual Cleaning Yearly before winter the pool heater should be drained and cleaned to remove any scale or sludge More frequent cleaning may be required if pool water contains sediment or any ...