MAINTENANCE
Element Inspection and Replacement:
1. Turn off power at main disconnect switch and turn off pump.
2. Drain pool heater.
3. Remove service access panel opposite inlet/outlet.
4. Disconnect element wires.
5. Remove element flange retaining nuts and extract element.
6. Installation is the reverse of steps 1 through 5.
(Reinstall element with new gasket)
When closing down the pool for any length of time, shut off the power at the main
disconnect switch and drain the water from the system. Water must not be allowed to
freeze in the heater, as this will cause severe damage.
Annual Cleaning:
Yearly, before winter, the pool heater should be drained and cleaned to remove any
scale or sludge. More frequent cleaning may be required if pool water contains
sediment or any amount of foreign matter.
1. Turn off heater at main disconnect switch.
2. Open drain valve.
3. Permit water to run until it is clear.
4. Close valve and restart normally.