MaxiProx DFM Reader Installation Manual 5375-901 Rev D
Page
5 of 20
Chapter 1 MaxiProx System Overview
The MaxiProx Reader is a self-contained proximity Reader. The two piece polycarbonate enclosure has
an O-ring that weather seals the enclosure pieces together and a cable fitting that seals the cable entry.
The water-resistant unit is designed for outdoor use. The enclosure is mountable on a single gang
electrical box. A bi-color LED and audible tone provide user feedback. Configurable open collector data
outputs provide the data to the Host. Configurable DIPswitches and jumpers provide choice of data
interfaces between Wiegand, Clock and Data, RS 232 and RS422. The data interface is configured as
ordered from the factory, but can be changed in the field - please contact
HID Technical Support
for
assistance. A tamper switch can alert the Host when the enclosure is opened. Internal DIP switches
and jumpers provide for configuration of the outputs, audible tone and LED control options.
Installation of the MaxiProx Reader consists of mounting, connecting the cable to the Host and
+12VDC or +24VDC power, verifying the DIPswitch and jumper settings, verifying Autotune, and
verifying the reading of a transponder.
1.1
1.1 Operation
Operation
Transponders (Proximity Cards or ProxKeys) are presented to the front of the MaxiProx. The LED is
red
when ready to read a transponder. The LED turns
green
and the beeper sounds when the tra nsponder
is read and the message is transmitted to the Host computer or interface panel. The system is ready for
another transponder as soon as the LED returns to
red
. There is an anti-passback delay of about one
and a half seconds before it will read the same card. The LED flash is typically 250 milliseconds long.
The operation of the LED and beeper may be controlled by the Host, in which case the actual operation
will depend on the programmed timing of the Host.
1.2
1.2 Parts List
Parts List
1.
MaxiProx Reader
Qty 1 (included)
2.
Installation Manual
Qty 1 (included)
3.
Cable Fitting
Qty 1 (included)
4.
Label for front cover - HID logo
Qty 1 (included)
5.
#6-32 x 1" flat head screw, for upper-left base mount
screw
Qty 1 (included)
6.
#6-32 x 1" black screw, for gang-box mounting
Qty 2 (included)
7.
#6-32 x .75" flat head screw, for front cover mounting
Qty 1 (included)
8.
Cable, 5 conductor, 22 AWG (Alpha 1295 C or
equivalent)
See cable notes
9.
Power Supply – 2.0 A linear regulated
+24VDC, nominal (+21 TO 28.5VDC)
Factory Default – No P2 Shunt Jumper
For Europe, use ALTRONIX SMP3
(USER SUPPLIED TRANSFORMER AND
BATTERY)
10.
+12VDC Shunt Jumper – P2-1 to P2-2 for 12VDC
operation
+12VDC, nominal (+11.6 to +20.9VDC)
For Europe , use ALTRONIX SMP3
(USER SUPPLIED TRANSFORMER AND
BATTERY)
1.3
1.3 Regulatory Approvals and Certifications
Regulatory Approvals and Certifications
§
Underwriters Laborites listing
§
CE Mark