background image

HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA  •  Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690 

http://www.hidcorp.com 

MaxiProx DFM Reader Installation Manual 5375-901 Rev D 

Page 

4 of 20

 

 

 
 
 

T

ABLES

 

 
 
T

ABLE 

1:  TB1 C

ONNECTOR 

D

EFINITION

...................................................................................................................................................... 7 

T

ABLE 

2:  TB2 C

ONNECTOR 

D

EFINITION

...................................................................................................................................................... 7 

T

ABLE 

3:  DIPS

WITCH AND 

J

UMPER 

S

ETTINGS

........................................................................................................................................... 8 

T

ABLE 

4:  I

NTERFACE 

J

UMPERS 

D

ESCRIPTION 

- P3 

AND 

P4 ...................................................................................................................... 8 

T

ABLE 

5:  S

WITCH 

D

ESCRIPTION 

- SW2 ....................................................................................................................................................... 8 

T

ABLE 

6:  M

ODE 

C

HART

.................................................................................................................................................................................. 8 

T

ABLE 

7:  B

AUD 

R

ATE 

C

HART 

– RS232 

AND 

RS422.................................................................................................................................... 8 

T

ABLE 

8:  S

WITCH 

D

ESCRIPTION 

- SW5 ....................................................................................................................................................... 9 

T

ABLE 

9:  L

OGIC 

L

EVELS

................................................................................................................................................................................. 16 

 
 
 
 
 

Проектирование

Монтаж

Продажа

. - http://vskd.ru

Summary of Contents for MaxiProx 5375A

Page 1: ...Irvine CA 92618 1905 USA Tel 949 598 1600 800 237 7769 Fax 949 598 1690 http www hidcorp com MaxiProx DFM Reader Installation Manual 5375 901 Rev D Page 1 of 20 Installation Manual 5375 901 Rev D Maxi...

Page 2: ...WER SUPPLY 10 2 12 AUTOTUNE OPERATION 10 2 13 READER TESTING 10 2 14 POWER UP TUNE 10 2 15 PERIODIC AUTOTUNE 10 2 16 SUPERVISOR MODE 10 2 17 INSTALL COVER 10 CHAPTER 3 INSTALLATION NOTES AND GUIDELINE...

Page 3: ...598 1690 http www hidcorp com MaxiProx DFM Reader Installation Manual 5375 901 Rev D Page 3 of 20 FIGURES FIGURE 1 MAXIPROX FRONT VIEW 11 FIGURE 2 MAXIPROX INTERIOR VIEW SHOWING MOUNTING HOLE LOCATIO...

Page 4: ...ual 5375 901 Rev D Page 4 of 20 TABLES TABLE 1 TB1 CONNECTOR DEFINITION 7 TABLE 2 TB2 CONNECTOR DEFINITION 7 TABLE 3 DIPSWITCH AND JUMPER SETTINGS 8 TABLE 4 INTERFACE JUMPERS DESCRIPTION P3 AND P4 8 T...

Page 5: ...Transponders Proximity Cards or ProxKeys are presented to the front of the MaxiProx The LED is red when ready to read a transponder The LED turns green and the beeper sounds when the transponder is r...

Page 6: ...meter 40 inches to another MaxiProx 2 3 2 3 Mounting Applications Mounting Applications The MaxiProx may be mounted to a gooseneck that is 1 inch in diameter with a 4 inch diameter mounting flange wit...

Page 7: ...ear of the MaxiProx Feed the cable through the cable fitting Connect the wires to the terminal strip with the minimum length necessary Do not leave extra loops of wire inside the Reader housing Connec...

Page 8: ...sh after valid card read 6 Single Dual external LED Off Off single line LED control On dual line LED control 7 Serial Baud 1 control Off See baud rate chart below 8 Serial Baud 2 control Off See Baud...

Page 9: ...e control line is necessary If ON it is in Dual Mode and the LED is normally off two control lines are necessary for host control of red and green 5 SW5 3 Terminating Resistor Some RS422 connections r...

Page 10: ...e additional flash beep is the correct sequence for Green Flash Beep on valid read SW1 5 off Three initial green flashes and beeps followed by a pause and then one additional beep indicate no Green Fl...

Page 11: ...onimo Road Irvine CA 92618 1905 USA Tel 949 598 1600 800 237 7769 Fax 949 598 1690 http www hidcorp com MaxiProx DFM Reader Installation Manual 5375 901 Rev D Page 11 of 20 Figure 1 MaxiProx Front Vie...

Page 12: ...NT TB2 9 TX TB2 8 TX 1 3 P2 5 1 TB1 9 1 TB2 P1 1 3 P4 3 1 1 3 P3 SHUNT PINS 2 AND 3 21 28 5 VDC DEFAULT SHUNT PINS 1 AND 2 11 20 VDC SW1 SW2 SW5 SW5 1 SW5 2 SW5 3 SW5 4 SW5 5 SW5 6 SW5 7 SW5 8 DATA 1...

Page 13: ...orbs energy from the Reader excite field and affects the signal being received from the card by re directing excite field transmissions into the receiver circuitry Moving the Reader away from the meta...

Page 14: ...ess control cards 3 4 3 4 Transponder Types Transponder Types The type of transponder used affects the read range of the MaxiProx The various styles of HID cards and transponders use different types o...

Page 15: ...s Code Format 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 P1 C C C C C C C C C C C C C C C C C C C C C C C C P2 Parity Format 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2...

Page 16: ...Logic Levels Voltage Data Outputs Data0 and Data1 Control Inputs LED s Hold Beeper Levels Minimum Maximum Minimum Maximum Voh 3 5V 5 5V 3 5V 5 5V Vol 0 0V 0 5V 0 0V 0 5V Ioh 0 0mA 5 0mA 1 0mA 0 0mA I...

Page 17: ...ed on Track 2 are 40 this product will output less than 40 characters The data consists only of BCD digits the remaining HEX digits A to F are used for the start and end sentinel data separators and c...

Page 18: ...tripe card traveling at 8 9 inches per second The timing is to be adjustable for cards traveling at 4 inches per second to 20 inches per second This relates to bit times of 3 3 ms and 666us respective...

Page 19: ...essage iiii LRC of nibbles aaaa to hhhh start B and end sentinel F xor of the nibbles or the even parity of the respective column The output from the Reader will look like the following 1248p 1248p 12...

Page 20: ...ue 7 is sent as an ASCII character 7 or the hex value E is sent as an ASCII character E The CC field is reserved for use by HID Corporation The valid values are 00 through 7F The DDDDDDDDDD field is t...

Page 21: ...ttp www hidcorp com MaxiProx DFM Reader Installation Manual 5375 901 Rev D Page 21 of 20 The checksum was computed by adding 00 01 23 4A BC DE 208 hex The checksum is the least significant 8 bits of t...

Reviews: