STRUCTURE AND PART NAMES

HP-150

/

200

Air pump

Start of production

Discontinuance of production

HP-150
HP-200

2001/9
2001/9

─ 
─ 

HP-150/200

 Filter Cover 

 Semi Cover Packing 

 Filter 

 Fitting Boss 

 Upper Housing 

 Sound Absorber (Lap) 

 Casing A 

 Valve Chamber Packing 

 Casing B 

 Valve 

 Diaphragm Ring 

 Diaphragm 

 Diaphragm Base 

 Actuating Rod 

 SP Switch 

 Safety pin +Locking collar 

 Frame Stay 

 Electromagnet 

 Frame Cover 

 L-Tube 

 Hose Band 

 Vibration Control Rubber 

 Center Plate 

 Gasket 

 Sound Absorber (Filter) 

 Lower Housing 

 Power Cord

Summary of Contents for hp-150

Page 1: ...er Cover Semi Cover Packing Filter Fitting Boss Upper Housing Sound Absorber Lap Casing A Valve Chamber Packing Casing B Valve Diaphragm Ring Diaphragm Diaphragm Base Actuating Rod SP Switch Safety pi...

Page 2: ...ul permanent magnets Therefore be sure to remove your watch and any other precision machines before operation as they may be affected by the strong magnetic force Do not put the actuating rod close to...

Page 3: ...t driver to loosen or tighten the U lock nut STEP 7 STEP 7 Fit a new diaphragm and diaphragm ring in the diaphragm base Be sure not to leave a gap between them Remove one of the diaphragm mounting blo...

Page 4: ...n fix them with 5 screws STEP 11 STEP 11 Fit the actuating rod by aligning it with the groove and tighten U lock nut and flat washer by the nut driver Use new U lock nut and washer otherwise U lock nu...

Page 5: ...ning boss on the diaphragm base into the concave part of the frame stay Secure the diaphragm mounting block on the other side and tighten washers and U lock nuts with the nut driver Make sure that gap...

Page 6: ...b of the actuating rod is even Be careful not to touch the terminal when the power is on testing the operating conditions as this will result in an electric shock Unplug the pump immediately after the...

Page 7: ...the hexagonal nuts by the nut driver 8mm wrench Loosen the screw holding the frame stay and remove it Pull out the electromagnet from the pump body CAUTION Be sure to unplug the pump unit When perform...

Page 8: ...he wires to the terminals Solder the wires to the terminals The wire requires a soldered connection Mount new electromagnet in the unit Fix frame stay temporarily Do not tighten screw of frame stay an...