Replacing the Chamber Block

HP-

150

/

200

REPLACING THE CHAMBER BLOCK

STEP

8

STEP

8

REPLACING THE VALVE

STEP

9

STEP

9

Insert each new valve into the center hold of valve 

seat, and secure them by pulling with radio pliers.

 

●When  reinstalling  the  valves,  make  sure  the  exhaust 

and intake sides are correctly fitted.

STEP

10

STEP

10

Cut  away  end  of  respective  valves  pulling  parts 

(just in front of thick parts) by scissors or nippers.

 

Hold the valve chamber packing between casing A 

and casing B. 

Then, fix them with 5 screws.

STEP

11

STEP

11

Fit the actuating rod by aligning it with the groove 

and tighten U-lock nut and flat washer by the nut 

driver.

 

●Use new U-lock nut and washer, otherwise, U-lock nut 

may work loose and cause malfunction.

FITTING CHAMBER BLOCKS

In  case  of  replacing  the  whole  diaphragm  casing 
block, move straight to 

STEP 11

separate  casing  A  and  casing  B,  by  removing  5 
inner screws. 
Remove the valves from casing B.

 

●If  it  is  difficult  to  separate  them,  insert  the  tip  of  a 

flatblade screwdriver into the clearance. 

●Pull out the valves as they can be removed easily. 

●Check if the valve chamber packing is broken.

CasingB

Valve  
Chamber  
Packing

CasingB

Valve  
Chamber  
Packing

CasingA

Summary of Contents for hp-150

Page 1: ...er Cover Semi Cover Packing Filter Fitting Boss Upper Housing Sound Absorber Lap Casing A Valve Chamber Packing Casing B Valve Diaphragm Ring Diaphragm Diaphragm Base Actuating Rod SP Switch Safety pi...

Page 2: ...ul permanent magnets Therefore be sure to remove your watch and any other precision machines before operation as they may be affected by the strong magnetic force Do not put the actuating rod close to...

Page 3: ...t driver to loosen or tighten the U lock nut STEP 7 STEP 7 Fit a new diaphragm and diaphragm ring in the diaphragm base Be sure not to leave a gap between them Remove one of the diaphragm mounting blo...

Page 4: ...n fix them with 5 screws STEP 11 STEP 11 Fit the actuating rod by aligning it with the groove and tighten U lock nut and flat washer by the nut driver Use new U lock nut and washer otherwise U lock nu...

Page 5: ...ning boss on the diaphragm base into the concave part of the frame stay Secure the diaphragm mounting block on the other side and tighten washers and U lock nuts with the nut driver Make sure that gap...

Page 6: ...b of the actuating rod is even Be careful not to touch the terminal when the power is on testing the operating conditions as this will result in an electric shock Unplug the pump immediately after the...

Page 7: ...the hexagonal nuts by the nut driver 8mm wrench Loosen the screw holding the frame stay and remove it Pull out the electromagnet from the pump body CAUTION Be sure to unplug the pump unit When perform...

Page 8: ...he wires to the terminals Solder the wires to the terminals The wire requires a soldered connection Mount new electromagnet in the unit Fix frame stay temporarily Do not tighten screw of frame stay an...

Reviews: