Replacing the Chamber Block

HP-

150

/

200

REPLACING THE CHAMBER BLOCK

STEP

16

STEP

16

Install the locking collar from the other side of the  

terminal and insert it until it clicks.

STEP

17

STEP

17

This  completes  the  replacement  of  the  safety  pin 

procedure. 

Make  sure  the  gap  between  L-shaped  lever  and 

tab of the actuating rod is even.

 

●Be careful not to touch the terminal when the power is 

on, testing the operating conditions as this will result in 
an electric shock. 

●Unplug the pump immediately after the check.

STEP

19

STEP

19

STEP

18

STEP

18

Install the sound absorber.

Place the upper housing back on body.

 

●Be  extremely  careful  not  to  catch  the  sound  absorber 

on the upper housing. 

Fasten it with the bolts. 

Then,  place  the  filter  and  filter  cover  on  the     

upper  housing.  (Refer  to 

FILTER  CLEANING  AND 

REPLACEMENT

)

Summary of Contents for hp-150

Page 1: ...er Cover Semi Cover Packing Filter Fitting Boss Upper Housing Sound Absorber Lap Casing A Valve Chamber Packing Casing B Valve Diaphragm Ring Diaphragm Diaphragm Base Actuating Rod SP Switch Safety pi...

Page 2: ...ul permanent magnets Therefore be sure to remove your watch and any other precision machines before operation as they may be affected by the strong magnetic force Do not put the actuating rod close to...

Page 3: ...t driver to loosen or tighten the U lock nut STEP 7 STEP 7 Fit a new diaphragm and diaphragm ring in the diaphragm base Be sure not to leave a gap between them Remove one of the diaphragm mounting blo...

Page 4: ...n fix them with 5 screws STEP 11 STEP 11 Fit the actuating rod by aligning it with the groove and tighten U lock nut and flat washer by the nut driver Use new U lock nut and washer otherwise U lock nu...

Page 5: ...ning boss on the diaphragm base into the concave part of the frame stay Secure the diaphragm mounting block on the other side and tighten washers and U lock nuts with the nut driver Make sure that gap...

Page 6: ...b of the actuating rod is even Be careful not to touch the terminal when the power is on testing the operating conditions as this will result in an electric shock Unplug the pump immediately after the...

Page 7: ...the hexagonal nuts by the nut driver 8mm wrench Loosen the screw holding the frame stay and remove it Pull out the electromagnet from the pump body CAUTION Be sure to unplug the pump unit When perform...

Page 8: ...he wires to the terminals Solder the wires to the terminals The wire requires a soldered connection Mount new electromagnet in the unit Fix frame stay temporarily Do not tighten screw of frame stay an...