REPLACING THE ELECTROMAGNET

STEP

1

STEP

1

REMOVAL OF ELECTROMAGNET

Cut the wire from the terminals on electromagnets 

with nippers.

 

●It is recommended that you make a note of the wiring.

STEP

2

STEP

2

Loosen the screw, fixing SP switch and remove it . 

(There  are  hexagonal  nuts  at  SP  switch  side.  Be 

sure not to lose them as they fall inside the unit.)

STEP

3

STEP

3

Remove the hexagonal nuts by the nut driver. 

(8mm wrench) 

Loosen  the  screw  holding  the  frame  stay,  and 

remove it. 

Pull out the electromagnet from the pump body.

CAUTION

! 

Be sure to unplug the pump unit.

 

When  performing  replacement  work,  the  pump  body  may  still  be  hot  and  you  could 
get burned. So please wait until the pump has cooled before handling.

 

Be  sure  to  remove  the  chamber  block  and  the  actuating  rod  before  replacing  the 
electromagnet.

 

It is better to let an experienced technician handle the soldering process. 
Take precautions against getting burned.

7

Replacing the Electromagnet

HP

Summary of Contents for hp-150

Page 1: ...er Cover Semi Cover Packing Filter Fitting Boss Upper Housing Sound Absorber Lap Casing A Valve Chamber Packing Casing B Valve Diaphragm Ring Diaphragm Diaphragm Base Actuating Rod SP Switch Safety pi...

Page 2: ...ul permanent magnets Therefore be sure to remove your watch and any other precision machines before operation as they may be affected by the strong magnetic force Do not put the actuating rod close to...

Page 3: ...t driver to loosen or tighten the U lock nut STEP 7 STEP 7 Fit a new diaphragm and diaphragm ring in the diaphragm base Be sure not to leave a gap between them Remove one of the diaphragm mounting blo...

Page 4: ...n fix them with 5 screws STEP 11 STEP 11 Fit the actuating rod by aligning it with the groove and tighten U lock nut and flat washer by the nut driver Use new U lock nut and washer otherwise U lock nu...

Page 5: ...ning boss on the diaphragm base into the concave part of the frame stay Secure the diaphragm mounting block on the other side and tighten washers and U lock nuts with the nut driver Make sure that gap...

Page 6: ...b of the actuating rod is even Be careful not to touch the terminal when the power is on testing the operating conditions as this will result in an electric shock Unplug the pump immediately after the...