HIBLOW hp-150 Manual Download Page 3

3

Replacing the Chamber Block

HP

HP-

150

/

200

REPLACING THE CHAMBER BLOCK

STEP

4

STEP

4

STEP

5

STEP

5

STEP

6

STEP

6

In  case  of  replacing  the  whole  diaphragm 

mounting block, move straight to 

STEP 11

Remove the diaphragm ring from the diaphragm, 

and  then,  detach  the  diaphragm  from  the 

diaphragm base.

REPLACING THE DIAPHRAGM

Remove  2  U-lock  nuts  from  one  side  holding  the 

diaphragm mounting block to the rod.

 

●Use the nut driver to loosen (or tighten) the U-lock nut.

STEP

7

STEP

7

Fit  a  new  diaphragm  and  diaphragm  ring  in  the 

diaphragm base.

 

●Be sure not to leave a gap between them.

Remove  one  of  the  diaphragm  mounting  blocks 
from  the  actuating  rod  and  pull  out  the  other 
diaphragm  mounting  block  with  the  rod.  After 
that, separate the diaphragm mounting block and 
the rod. 

●When pulling out the rod, be sure not to catch the rod 

projection on the lever of the SP switch. 

●If  the  pump  stops  automatically,  the  safety  pin  must  be  broken  to  prevent  any 

further damage to the pump. Be sure all broken pieces are removed from the unit. 
(See 

Step 14

)

Summary of Contents for hp-150

Page 1: ...er Cover Semi Cover Packing Filter Fitting Boss Upper Housing Sound Absorber Lap Casing A Valve Chamber Packing Casing B Valve Diaphragm Ring Diaphragm Diaphragm Base Actuating Rod SP Switch Safety pi...

Page 2: ...ul permanent magnets Therefore be sure to remove your watch and any other precision machines before operation as they may be affected by the strong magnetic force Do not put the actuating rod close to...

Page 3: ...t driver to loosen or tighten the U lock nut STEP 7 STEP 7 Fit a new diaphragm and diaphragm ring in the diaphragm base Be sure not to leave a gap between them Remove one of the diaphragm mounting blo...

Page 4: ...n fix them with 5 screws STEP 11 STEP 11 Fit the actuating rod by aligning it with the groove and tighten U lock nut and flat washer by the nut driver Use new U lock nut and washer otherwise U lock nu...

Page 5: ...ning boss on the diaphragm base into the concave part of the frame stay Secure the diaphragm mounting block on the other side and tighten washers and U lock nuts with the nut driver Make sure that gap...

Page 6: ...b of the actuating rod is even Be careful not to touch the terminal when the power is on testing the operating conditions as this will result in an electric shock Unplug the pump immediately after the...

Page 7: ...the hexagonal nuts by the nut driver 8mm wrench Loosen the screw holding the frame stay and remove it Pull out the electromagnet from the pump body CAUTION Be sure to unplug the pump unit When perform...

Page 8: ...he wires to the terminals Solder the wires to the terminals The wire requires a soldered connection Mount new electromagnet in the unit Fix frame stay temporarily Do not tighten screw of frame stay an...

Reviews: