Replacing the Chamber Block
HP
HP-
150
/
200
REPLACING THE CHAMBER BLOCK
STEP
12
STEP
12
STEP
13
STEP
13
STEP
14
STEP
14
Check that the broken pin is removed from unit.
●If the broken pin is left inside the unit, it can get caught
in between electromagnets and actuating rod, which
can cause breakdown.
REPLACEMENT OF SAFETY PIN
Insert the actuating rod into the machine body. Be
sure to fit the positioning boss on the diaphragm
base into the concave part of the frame stay.
Secure the diaphragm mounting block on the
other side and tighten washers and U-lock nuts
with the nut driver.
Make sure that gap between the actuating rod
and the electromagnets is even.
Mount the casing block with screws (4 screws on
each side).
And insert L-tube into the nozzle of casing A.
Then, fix it with hose clip.
Complete the other casing block in the same way.
STEP
15
STEP
15
Insert a new safety pin through the hole on the
terminal side.
(Please Insert safety pin through the spring
electrode, L-shaped lever in such order.)