FRU Replacement Guide
5 Storage Interconnect Replaceable Units
63
Chapter
5
5 Storage Interconnect Replaceable Units
Topics:
•
•
•
•
•
This section provides replacement procedures for the following parts in a Storage
Interconnect:
• Chassis
• Fan
• PSU
5.1 Warnings
Caution:
All data on the Active Archive System is unavailable during repair.
5.2 Switch Replacement Procedure
Prerequisites
• Obtain a replacement Storage Interconnect from HGST.
• Obtain the switch configuration file from HGST.
Required Tools
• Ladder
• Long Phillips-head screwdriver
Time Estimate:
Unknown.
Important:
If Storage Interconnect 1, (
SWA
, lower), is down, then IPMI is down.
To replace a Storage Interconnect, proceed as follows:
1.
Edit the switch configuration file you obtained from HGST as follows:
a) Modify the IP address for the syslog target to match your environment.
The syslog target is the Management Node.
b) Modify the IP address for VLAN to match your environment.
c) Modify the time and time zone to match your environment.
2.
Load your modified configuration file into the new Storage Interconnect as follows:
a) Log into the new Storage Interconnect.
Replace
switchport_IP
with the default IP address of the new Storage Interconnect:
For switch 1 (lower), the default IP address is
192.168.123.123
.
For switch 2 (upper), the default IP address is
192.168.123.123
.
The default username is
admin
. There is no password.
telnet
switchport_IP