FRU Replacement Guide
4 Storage Node Replaceable Units
55
Sanity check: you can observe that the Storage Enclosure Basic LEDs are now solid green. In addition, the CMC shows
the node status as
RUNNING
.
Figure 29: Storage Node Status in the CMC
The chassis replacement procedure is done.
Warning:
Be very careful when recording and updating MAC addresses. A mistake may render the new
chassis unusable.
Item
Value
Virtual IP Address of the Management Node:
Get this value as instructed in the
Administrator
Interfaces
chapter in the
HGST Active Archive System
Troubleshooting Guide
Original Hostname of Node:
Get this value from the CMC
before
you shut down
the failed node. This value is typically of the format
SystemID
-DC
nn
-R
nn
-SN
nn
.
Temporary IP Address of Node:
The CMC displays this value
after
the new chassis is
installed.
Temporary Hostname of Node:
The CMC displays this value
after
the new chassis is
installed. This value is of the format
PM-
MAC_ADDRESS
.
MAC Address of Node:
IPMI IP Address of Node:
IPMI MAC Address of Node:
Serial Bus Path
MAC Address on the New
Chassis
Ethernet Port Name
NIC Array ID
0000:01:00.0
eth0