Heta SCAN-LINE 800 AQUA Operating Instructions Manual Download Page 9

9

Installation and Operating Instructions for Heta SL800 Aqua stove Pevex1018/AH/ver1:Jan 2013

The chimney must be swept at least 

once a year, we recommend the use 

of a NACS (national association of 

chimney sweeps) registered chim-

ney sweep. In the event of smoke or 

malodorous fumes being produced, 

you must first check to see whether 

the chimney is blocked. The chim-

ney must, of course, always provide 

the minimum draught necessary to 

ensure that it is possible to regulate 

the fire.  Please note, however, that 

chimney draft is dependent on the 

weather conditions. In high winds, the 

draft can become so powerful that it 

may be necessary to fit a damper in 

the flue gas pipe to regulate the draft. 

When cleaning the chimney, soot and 

other deposits may come to fall on the 

smoke turning plate.

  

In cases where 

the wood burns too quickly, this may 

be due to excessive chimney draught.  

You should also check to make sure 

that the door seal is intact and cor-

rectly fitting.

If the stove it generating too little heat, 

this may be because you are firing 

with wet wood. In this case, much of 

the heating energy is used to dry the 

wood, resulting in poor heating eco-

nomics and an increased risk of soot 

deposits in the chimney.

OPERATIONAL PROBLEMS 

MAINTENANCE

The surface of the stove has been 

treated with heat-resistant paint.

The stove should be cleaned with a 

damp cloth. Any damage to the sur-

face in the form of chips or scratches 

can be repaired using touch-up paint, 

which is available in spray cans.

Cleaning the glass

Incorrect firing, for example using 

wet wood, can result in the viewing 

window becoming covered in soot. 

This soot can be easily and effectively 

removed by using proprietary stove 

glass cleaner.

VENTILATION

Adequate ventilation must be provided 

in accordance with building regulati-

ons (Doc J Oct 2010) especially when 

installing in newer build properties 

when the stove is not going to be 

installed to an outside air supply.

The Heta SL800 requires a permanent 

air vent opening of minimum 550sq 

mm under Building Regulations if 

the stove is not going to be fitted to 

an external outside fresh air supply.  

Houses built after 2008 where the air 

leakage rate is less than than 5m

3

/

hour/m

2

 then a ventilator equivalent to 

550mm

2

 per kW output will be re-

quired (9kW x 550mm = 4950mm

2

).

Summary of Contents for SCAN-LINE 800 AQUA

Page 1: ...ns for Heta SL800 Aqua stove Pevex1018 AH ver1 Jan 2013 www heta dk SCAN LINE 800 AQUA APPROVED FOR USE IN SMOKE CONTROL AREAS WHEN BURNING DRY WOOD LOGS OR AUTHORISED FUELS OPERATING INSTRUCTIONS GB...

Page 2: ...the floor area must match national and local regulations The chimney connection The chimney opening must follow national and local regulations Howe ver the area of the opening should of specifications...

Page 3: ...e weight of the chimney excessive weight may cause damage on or noise from the stove Draft conditions Poor draft may result in smoke being emitted from the stove when the door is opened The minimum ch...

Page 4: ...me correct firing prevents environ mental damage in the form of smoke and emmissions and also reduces the risk of chimney fires If the wood is wet and inadequately seasoned a large proportion of the e...

Page 5: ...top position fig 1 Reduce combu stion airflow gradually by lowering the handle When the handle is in the lowest position fig 2 combustion airflow is completely closed Fig 1 Fig 2 Open Closed The SL80...

Page 6: ...go out a red hot ember bed will be left and further wood can be added 6 Place 2 3 logs on the ash bed ensu ring that the wood is not stacked too closely and with the adjust the side airslider to fully...

Page 7: ...air controls or dampers left open except as directed in the instructions Refuelling A fresh supply of fuel should nor mally be added while there is still a good layer of hot embers Spread the embers...

Page 8: ...ary and se condary air in these instructions we call this combustion air The stove provides excellent heating efficiency and the window is easy to maintain as the secondary air flushes the surface of...

Page 9: ...ith wet wood In this case much of the heating energy is used to dry the wood resulting in poor heating eco nomics and an increased risk of soot deposits in the chimney OPERATIONAL PROBLEMS MAINTENANCE...

Page 10: ...the dealer Therefo re the stoves are guaranteed against defects in manufacturing FOR FIVE YEARS This guarantee does not cover Wea ring parts fragile parts such as The fire proof bricks in the combu s...

Page 11: ...ns for Heta SL800 Aqua stove Pevex1018 AH ver1 Jan 2013 Connection of external air flow fresh air through the floor on Scan Line 800 Aqua When connection external air flow use a 100 air conduit for in...

Page 12: ...Operating Instructions for Heta SL800 Aqua stove Pevex1018 AH ver1 Jan 2013 4 5 6 7 Emptying the ash pan fig 4 7 Cleaning after sweeping the chimney and replacing the stones Fig 8 14 Scan Line 800 Aqu...

Page 13: ...etween the cooling pipes lies as as sembled on the picture as when you receive it from Heta otherwise it will result in great loss of efficiency and raise the temperature of the chimney Tip the top pl...

Page 14: ...AH ver1 Jan 2013 Connection water to Scan Line 800 Aqua Fig 20 Bleed screw SYR Temperature valve pkt 5 Forward motion warm 1 2 RG point 4 12 mm copper pipe for water connection point 1 Return cold 1 2...

Page 15: ...sure The SYR valve point 5 is an extra safety device which opens by a tem perature over 95 in the boiler Connect cold water pressure on maxi mum 15 on the water connection point 1 make sure that your...

Page 16: ...d In Scotland and Wales this power rests with Ministers in the de volved administrations for those coun tries Separate legislation the Clean Appendix A Air Northern Ireland Order 1981 ap plies in Nort...