Installation and Operating Instructions for Heta SL800 Aqua stove Pevex1018/AH/ver1:Jan 2013

It is advised not to use very oil-

containing woods like teak tree 

and mahogany, as this can cause 

damage to the glass.

Heating value in wood

You have to use about 2.4 kg normal 

wood to replace one litre of heating 

oil. All woods have almost the same 

heating value per kg, which is about 

5.27 kW/hour for absolute dry wood. 

Wood with a moistness of 18% has a 

efficiency of about 4.18 kW/hour per 

kg, and one litre heating oil contains 

about 10 kW/hour.

CO

2

 release

At combustion 1000 litres of heating 

oil forms 3.171 tons CO

2

. As wood 

is a CO

2

 neutral heat/ energy source, 

you save the environment about 1.3 

kg CO

2

 every time you have used 1 kg 

normal wood.

Chimney fires

In the event of a chimney fire – which 

often results from incorrect operation 

or protracted firing with moist wood 

– close the door and shut off the se-

condary/start-up air supply to smother 

the fire. Call the fire department.

Airflow regulation

To adjust combustion airflow, use 

the handle on the side (towards the 

rear). There is maximum combustion 

airflow in when the handle is in the 

top position (fig. 1). Reduce combu-

stion airflow gradually by lowering 

the handle. When the handle is in the 

lowest position (fig. 2), combustion 

airflow is completely closed. 

Fig. 1

Fig. 2

Open

Closed

The SL800 Aqua stoves are designed 

and tested to burn extremely cleanly 

with very little smoke discharge and 

are exempt for use in smoke con-

trol areas throughout the UK when 

burning dry wood logs.  To comply, 

a permanent stop is fitted to ensure 

that the air control slider cannot be 

closed beyond 52% of its fully open 

position. A permanent amount of air 

will therefore enter the firebox to feed 

the fire producing negligible amounts 

of smoke and unburnt hydrocarbons.  

The appliances will only be conside-

red as an exempt appliances if this 

stop is in place.

Lighting the stove

To light the stove, use firelighters, 

paraffin firelighter bags or small 

pieces of wood. Place over the grate. 

Place larger logs over the fire-lighting 

material, at right angles to the door. 

Turn handle to top position for max. 

Combustion- airflow. The stove door 

should be slightly ajar (about 1 cm). 

When the wood is well lit and the 

chimney is hot (after about 10 mi-

nutes), close the stove door. When 

lighting the stove from cold, we re-

commend that the combustion airflow 

is at maximum until the first stack of 

wood has burned out so that the stove 

and chimney are heated through.

Summary of Contents for SCAN-LINE 800 AQUA

Page 1: ...ns for Heta SL800 Aqua stove Pevex1018 AH ver1 Jan 2013 www heta dk SCAN LINE 800 AQUA APPROVED FOR USE IN SMOKE CONTROL AREAS WHEN BURNING DRY WOOD LOGS OR AUTHORISED FUELS OPERATING INSTRUCTIONS GB...

Page 2: ...the floor area must match national and local regulations The chimney connection The chimney opening must follow national and local regulations Howe ver the area of the opening should of specifications...

Page 3: ...e weight of the chimney excessive weight may cause damage on or noise from the stove Draft conditions Poor draft may result in smoke being emitted from the stove when the door is opened The minimum ch...

Page 4: ...me correct firing prevents environ mental damage in the form of smoke and emmissions and also reduces the risk of chimney fires If the wood is wet and inadequately seasoned a large proportion of the e...

Page 5: ...top position fig 1 Reduce combu stion airflow gradually by lowering the handle When the handle is in the lowest position fig 2 combustion airflow is completely closed Fig 1 Fig 2 Open Closed The SL80...

Page 6: ...go out a red hot ember bed will be left and further wood can be added 6 Place 2 3 logs on the ash bed ensu ring that the wood is not stacked too closely and with the adjust the side airslider to fully...

Page 7: ...air controls or dampers left open except as directed in the instructions Refuelling A fresh supply of fuel should nor mally be added while there is still a good layer of hot embers Spread the embers...

Page 8: ...ary and se condary air in these instructions we call this combustion air The stove provides excellent heating efficiency and the window is easy to maintain as the secondary air flushes the surface of...

Page 9: ...ith wet wood In this case much of the heating energy is used to dry the wood resulting in poor heating eco nomics and an increased risk of soot deposits in the chimney OPERATIONAL PROBLEMS MAINTENANCE...

Page 10: ...the dealer Therefo re the stoves are guaranteed against defects in manufacturing FOR FIVE YEARS This guarantee does not cover Wea ring parts fragile parts such as The fire proof bricks in the combu s...

Page 11: ...ns for Heta SL800 Aqua stove Pevex1018 AH ver1 Jan 2013 Connection of external air flow fresh air through the floor on Scan Line 800 Aqua When connection external air flow use a 100 air conduit for in...

Page 12: ...Operating Instructions for Heta SL800 Aqua stove Pevex1018 AH ver1 Jan 2013 4 5 6 7 Emptying the ash pan fig 4 7 Cleaning after sweeping the chimney and replacing the stones Fig 8 14 Scan Line 800 Aqu...

Page 13: ...etween the cooling pipes lies as as sembled on the picture as when you receive it from Heta otherwise it will result in great loss of efficiency and raise the temperature of the chimney Tip the top pl...

Page 14: ...AH ver1 Jan 2013 Connection water to Scan Line 800 Aqua Fig 20 Bleed screw SYR Temperature valve pkt 5 Forward motion warm 1 2 RG point 4 12 mm copper pipe for water connection point 1 Return cold 1 2...

Page 15: ...sure The SYR valve point 5 is an extra safety device which opens by a tem perature over 95 in the boiler Connect cold water pressure on maxi mum 15 on the water connection point 1 make sure that your...

Page 16: ...d In Scotland and Wales this power rests with Ministers in the de volved administrations for those coun tries Separate legislation the Clean Appendix A Air Northern Ireland Order 1981 ap plies in Nort...

Reviews: