8.10.3
Hot water tank
Übersicht
Status
Settings
Fast start
Full-loading
Hot water tank temperature
Loading valve
Hot water tank pump
Hot water tank temperature bottom
Load-through valve
Circulation temperature
Circulation pump
Must temperature
Min. loading / temperature
Temp. increase
Max. Loading time
Legio temperature
Circulation pump
Loading valve
Time program
Agg-Test
Time
Hot water tank pump
Loading valve
Load-through valve
Circulation pump
Term
Description
Unit
Overview
Fast start
Activates the fast start up (ON/OFF)
If fast start up is activated, the hot water tank is heated independently
(maximum loading time) to the requested set temperature.
-
Full-loading
Activates a full loading of the hot water tank (ON/OFF)
If full-loading is activated, the hot water tank is heated up to the
requested set temperature
(
only available, if second temperature sensor is installed)
-
Status
Hot water tank
temperature
Indicates the hot water tank upper zone temperature
°C
Loading valve
Indicates the state of the loading valve
(
only visible, if hot water tank pump is activated)
-
Hot water tank pump
Indicates the state of the hot water tank pump
(
only visible, if loading valve is inactivated)
-
Hot water tank
temperature bottom
Indicates the hot water tank bottom zone temperature
(
only visible, if second temperature sensor is installed
°C
Load-through valve
Indicates the state of the load-through valve
(
only visible, if load-through valve is activated and a heat pump is
installed)
-
Circulation
temperature
Indicates the circulation temperature
(
only visible, if circulation pump is activated)
°C
Circulation pump
Indicates the state of the circulation pump
(
only visible, if circulation pump is activated)
-
Settings
Must temperature
Setting up the hot water tank set temperature
°C