2.1 Mixing device

A blue flame burner mixing device is used to burn the mixture. The fuel spray
that escapes from the nozzle evaporates before the actual reaction of com-
bustion by a mixture of hot flue gases. The low temperature level within the
evaporation zone, and the water content of the returned combustion gases,
prevent the formation of soot. The intensity of the backflow is indicated by
the rate of recirculation that measures the proportion of the  recirculated flow
of flue gas of the entire gas mass flow. Low rates of  recirculation favour the
formation of soot. The solid state of soot particles confers a yellow colour
to the flame. An increase of the combustion gas recirculation reduces the
formation of soot and leads finally to a completely soot-free flame that emits
a hardly visible bluish radiation to the human eye.
In order to achieve an intensive recirculation of flue gas over the entire
performance range in combination with a high stability of the flame the
combustion air is supplied in a swirled jet. The image below shows
 schematically the mode of operation of the mixing device. The combus-
tion air enters through a nozzle into the flame tube. 
Due to the rapid cross-sectional enlargement of the air jet a vacuum
accrues at the edge of the air nozzle through which the hot flame gases
are transported from the inside of the flame conduit into the evaporating
zone. Besides this, already cooled-off combustion gases reach through
the openings of the flame tube from the combustion chamber into the
evaporation zone. Additionally, a back streaming is formed due to the
twisted streaming of the combustion air in the rotation centre of the flame.
Besides the avoidance of soot formation the intensive return of flue gases
to the flame’s root also achieves a reduction of nitrogen oxide emissions
(NOx). Two mechanisms essentially help this occur. On the one hand the
oxygen partial pressure of the mixture is reduced. Therefore the local con-
centration of dissociated oxygen molecules that react with the nitrogen
of the combustion air to NOx is reduced. On the other hand the flame
temperature is reduced through the recirculating flow of inert flue gases
with a higher specific heat capacity (CO

2

and H²O).

A

Swirl generator

B

Ignition electrode

C

Air nozzle

D

External recircu-
lation zone

E

Internal recircu-
lation zone

F

Flame

G

Flame tube

H

Injection nozzle

I

Oil preheater

K

Air

Mixing device

2.2 Combustion air blower

The combustion air is supported through a patented hybrid blower that
distinguishes itself by its extreme compressive rigidity. This ensures a pul-
sation-free and delay-free start of the burner, particularly at high combus-
tion chamber counter-pressure. The immense efficiency of the fan creates
a clear reduction of electrical energy over conventional fan solutions. With
room dependent or air dependent operating methods it is possible to re-
place the protection cover at the fan inlet by a suction air silencer that is
deliverable as an accessory. In the case of room air independent operation
there are inlet adapters with fitting diameter of Ø 50 mm or Ø 80 mm avai-
lable. In addition a turnable suction socket is offered with a fitting diameter
of Ø 50 mm that can be combined with a upstream mounted silencer. 

2.3 Fuel pump and nozzle closing system

A gear pump is used as the fuel pump. The figure shows a diagram of the
hydraulic system of a single stage oil pump. The gear wheel set of the

H

I

G

C

K

A

D

E

B

F

pump delivers the fuel through a cartridge filter from the storage tank of
the oil supply system to the oil nozzle. The required injection pressure is
adjusted on the pressure control valve. A solenoid valve is fitted to control
the process of injection. This solenoid valve is closed in current-less con-
dition. In this switching state the entire fuel stream flows back through the
pressure control valve into the storage tank. For the fuel injection the so-
lenoid valve will be provided with current and consequently opened. The-
reupon the fuel reaches the nozzle due to the adjusted pressure at the
pressure control valve.

In order to reduce the start-up
and switch-off emissions the bur-
ner has been equipped in series
with a nozzle closing system by
Danfoss (LE system).
For this a spring-loaded dia-
phragm valve is installed into the
oil pre-heater. This will open at an
oil pressure of approximately 5
bars, and closes due to the spring
resistance at approximately 3
bars. To speed up the closing pro-
cess of the valve when turning off

the burner, or to prevent a pressurisation in the nozzle line by external ef-
fects (e.g. oil pre-heating at start of burner, radiation from the combustion
chamber after the burner’s switch-off), the LE oil pump is provided with a
bypass channel between the pressure and suction side. A spring-loaded
overflow valve with an opening pressure of 2 bars has been integrated in-
side the bypass channel. Due to the volumetric expansion caused by the
temperature the pressure increases in the oil pre-heater. As soon as the
pressure increases to 2 bars the overflow valve in the bypass channel
opens. However, the diaphragm valve in the pre-heater remains closed
due to the higher opening pressure and consequently prevents an esca-
ping of the fuel. Upon expiration of the heating up phase the burner motor
will start up, whereby the adjusted pressure on the pressure controller in-
side the pump builds up. At the end of the pre-ventilation period the so-
lenoid valve opens. The rising injection pressure inside the oil pre-heater
opens the diaphragm valve and the injection process starts in a controlled
manner, with the opening pressure pre-adjusted by the diaphragm valve.
Since the decrease of pressure on the diaphragm valve is negligible the
prevailing pressure on the oil nozzle corresponds with the pressure that
has been measured on the pump. In order to keep the partial stream that
is flowing off through the bypass as low as possible during the operation

of the burner a faceplate has
been additionally integrated in-
side the bypass channel. As soon
as the burner turns off the sole-
noid valve will close and the in-
jection pressure relieves itself
through the nozzle. As soon as
the pressure falls below 3 bars
the diaphragm valve inside the oil
pre-heater will close. This will en-
sure a controlled end of the in-
jection process without any furt-
her dripping. The LE oil pump
may also be used as a standard
oil pump. By turning the adjust-
ment screw in accordance with
the illustration you may activate
or de-activate the LE system.

2.4 Flame monitoring

Three optional systems are available as flame monitoring systems, namely
two optical flame detectors as well as an ignition unit with integrated ioni-
sation flame monitoring. These systems will be represented subsequently.

Optical flame detector, KLC 2002

Real flames release luminous radiation with an unsteady changing fre-
quency. This kind of “flickering“ of the flame is used for the especially de-
veloped optical flame detector (BST Solutions KLC 2002) for blue flame
burners to recognise flames. The evaluation of the optical signal, as well
as the conversation into an evaluated signal, occurs through a micro pro-
cessor based control that is integrated into the flame detector. This flame
detector differs from other optical flame monitoring devices in that it eva-
luates only the flickering of the flame. The constant luminous radiation of
the glowing recirculation tube or other components inside the combustion
chamber is completely cut out. A radiation with constant frequency, also
leads to no flame detection. It is not necessary to adjust the sensitivity.
Only an LED in the flame detectors housing indicates the current operating
state of the flame sensor. Following modes can be distinguished:

LED is OFF: 

Flame monitor is carrying no current

LED is flashing: 

KLC is active, no flame has been detected

LED is permanently ON: 

KLC is active, flame has been detected

-ÕV̈œ˜ÊÈ`i

*ÀiÃÃÕÀiÊÈ`i

,iÌÕÀ˜

 Þ«>ÃÃÊV>˜>

i>ÃÕÀiÊi˜ÌÀÞ]
«ÀiÃÃÕÀiÊÈ`i

i>ÃÕÀiÊi˜ÌÀÞ]Ê
ÃÕV̈œ˜ÊÈ`i

"ÀˆvˆVi

"ÀˆvˆVi

>ÀÌÀˆ`}iÊvˆÌiÀ

`ÕÃ̈˜}ÊÃVÀiÜÊ
ÊÃÞÃÌi“

"ˆÊ«Ài…i>ÌiÀ

"ˆÊ˜œââi

ˆ>«À>}“ÊÛ>ÛiÊ
«œÊrÊxL>À

ݏiÊÃi>

*ÀiÃÃÕÀiÊVœ˜ÌÀœÊÛ>Ûi

"ÛiÀÊvœÜÊÛ>ÛiÊ«œÊrÊÓL>À

-œi˜œˆ`ÊÛ>Ûi

-iÌ̈˜}ÊÃVÀiÜÊvœÀÊ
Ã܈ÌV…ˆ˜}ʜ˜iʏˆ˜i‡ÊÉÊ
Ìܜʏˆ˜iʜ«iÀ>̈œ˜

œ˜˜iV̈œ˜Ê
œˆÊÃÕ««ÞÊ

Hydraulic diagram – single stage oil pump

ON

OFF

ON

OFF

LE

LE 
diaphragm
valve

Activation/de-activation of the 
LE system

Summary of Contents for HL 60 GLV.2-S

Page 1: ...uciatore gasolio www herrmann burners de DE Technische Information Montage und Betriebsanleitung EN Technical information Assembly and operating instructions FR Caract ristiques techniques Instruction...

Page 2: ...echnische Information Montage und Betriebsanleitung Technical information Assembly and operating instructions Caract ristiques techniques Instructions de montage et de service Informazioni tecniche Is...

Page 3: ...drucksteife Gebl se garantiert einen pulsationsfreien Start des Brenners Dank weiterer qualitativ hochwertiger Komponenten ist ein zuverl ssiger Betrieb des Brenners ber eine lange Lebensdau er siche...

Page 4: ...assification 3 the German Envi ronmental Label Blue Angel in accordance with RAL UZ 9 and the Swiss Ordinance on Air Pollution LRV The extremely pressure stiff blower designed specifically for the com...

Page 5: ...ection de l air OPair La ventilation extr mement rigide la pression sp cialement con ue pour la combustion du fioul garantit un d marrage du br leur sans pulsation Gr ce d autres composants de haute q...

Page 6: ...emamente resistente alla pressione progettato speci ficamente per la combustione di olio combustibile garantisce un avvio senza pulsazioni del bruciatore Grazie ad altri componenti di alta qua lit si...

Page 7: ...otor Hanning O1A095 055 lpumpe Danfoss BFP 21 L3 LE lvorw rmer Danfoss FPHE LE PTC 50 Z ndeinheit Danfoss EBI 4 Beru ZT mit Flammen erkennung Flammen berwachung Honeywell IRD 1010 1 rot axial BST Solu...

Page 8: ...d flie t der gesamte Brennstoffstrom ber das Druckregelventil zu r ck in den Vorratstank Zur Brennstoffeinspritzung wird das Magnetventil bestromt und damit ge ffnet Der Brennstoff gelangt daraufhin m...

Page 9: ...nd wird die Empfindlichkeit wieder soweit erh ht dass beide LED leuchten Danach muss der Brenner erneut gestartet werden Dabei muss berpr ft werden dass LED 1 w hrend der Vorbel ftung nicht flackert A...

Page 10: ...permanent rot Dieser Zustand bleibt auch bei Netzspannungsunterbrechung erhalten Der elektronische Feuerungsautomat LMO14 verf gt zudem ber eine visuelle Betriebsanzeige und St rursachendiagnose welc...

Page 11: ...m betrieben oder einem Zweistrangsystem betrieben werden Serienm ig ist der Brenner auf Zweistrangsysteme voreingestellt Bei der Umstellung der Pumpe auf Einstrangbetrieb muss der R cklaufstutzen mit...

Page 12: ...schl uche in eine gelochte Gummit lle eingelegt die wiederum in die Ausnehmung der Grundplatte eingesetzt wird Die jeweils nicht benutzte Ausnehmung der Grundplatte wird mit einer ungelochten T lle Bl...

Page 13: ...n gr e und dem am Druckregler der l pumpe eingestellten Einspritzdruck Durch Drehen der Stell schraube im Uhrzeiger sinn erh ht sich der l druck und damit der eingespritzte lmas senstrom Umgekehrt ver...

Page 14: ...60 80 100x150 24 10 0 5 4 23 4 4 5 2 5 2 5 HL 60 KLV 2 S 26 2 19 0 60 80 100x150 24 11 0 6 3 27 4 4 5 2 5 2 5 HL 60 KLV 2 S 27 2 28 0 60 80 100x150 24 11 2 6 5 28 4 4 5 2 5 2 5 HL 60 KLV 2 S 28 2 36 0...

Page 15: ...N 6 h 1 2 nur bei LMO 14 A1 Siemens LOA 24 LMO 14 gr n braun gelb wei 31 32 N 3 R Nachlaufrelais TR 120 1 L N S schwarz blau braun 12 11 1 1 2 3 braun gelb gr n blau 4 N 1 2 V blau gelb gr n braun N 3...

Page 16: ...15 DE 7 Explosionszeichnung mit Ersatzteilliste...

Page 17: ...itflansch Dichtung N P Unit 10006 00062 3 Brennerrohr N P Unit 10005 00078 4 Dichtung f r Brennerrohr N P Unit 10006 00058 5 Unitflansch geneigt N P Unit 10002 00121 6 O Ring 99x4 Viton 10006 00059 7...

Page 18: ...itig und Unitflansch 10023 00020 Zylinderkopfschraube mit Innensechskant SW4 hnl DIN 912 M4x18 f r Abdeckung 10023 00184 Senkschraube mit Kreuzschlitz DIN 965 M3x5 f r Haltering Dichtung 10023 00043 Z...

Page 19: ...e defekt lpumpe austauschen Parafinausscheidungen 4 C K ltesicher verlegen Heiz l nicht mehr fliessf hig 1 C K ltesicher verlegen 5 Magnetventil Magnetventil ffnet nicht Spule des Magnetventils defekt...

Page 20: ...V 2 S KLV 2 S NLV 2 S PLV 2 S Grundplatte Schiebeflansch HL 60 GLV 2 S ILV 2 S KLV 2 S NLV 2 S PLV 2 S Grundplatte Unitflansch HL 60 GLV 2 S ILV 2 S KLV 2 S NLV 2 S PLV 2 S Grundplatte Mini Unitflansc...

Page 21: ...20 DE 9 Brennerabmessungen HL 60 GLV 2 S ILV 2 S KLV 2 S Schiebeflansch HL 60 GLV 2 S ILV 2 S KLV 2 S Unitflansch HL 60 GLV 2 S ILV 2 S KLV 2 S Schiebeflansch HL 60 GLV 2 S ILV 2 S KLV 2 S Unitflansch...

Page 22: ...21 DE HL 60 NLV 2 S PLV 2 S Schiebeflansch HL 60 NLV 2 S PLV 2 S Unitflansch HL 60 NLV 2 S PLV 2 S Schiebeflansch HL 60 NLV 2 S PLV 2 S Unitflansch 9 Brennerabmessungen...

Page 23: ...des Gebl senachlaufes bieten wir zwei ver schiedene Nachbel ftungssysteme an Feuerungsautomat Siemens LMO64 Eine elegante Art den Brenner mit der Nachbel ftungsfunktion auszustat ten stellt der Einsat...

Page 24: ...en Heiz lmenge sowie der Brennerlaufzeit bieten wir den Einbau einer Kombination aus ldurchlauf und Betriebs stundenz hler an Der Einbau des ldurchlauf und Betriebsstundenz h lers kann werksseitig erf...

Page 25: ...nning O1A095 055 Oil pump Danfoss BFP 21 L3 LE Oil pre heater Danfoss FPHE LE PTC 50 Ignition Danfoss EBI 4 Beru ZT with flame monitoring Flame control Honeywell IRD 1010 1 red axial BST Solutions Wid...

Page 26: ...ly opened The reupon the fuel reaches the nozzle due to the adjusted pressure at the pressure control valve In order to reduce the start up and switch off emissions the bur ner has been equipped in se...

Page 27: ...eased so that both LED s are lighting up You should then start the burner again You should check that LED 1 is not flickering during the pre ventilation For safety reasons make sure that the sensitivi...

Page 28: ...vent of in terruption of the mains voltage The LMO14 electronic oil firing unit also features a visual operating display and trouble shooting diagnosis that are displayed through the multi co loured L...

Page 29: ...ssure should be 0 1 mbar For pressure boilers you should gather the chimney draught that needs to be adjusted from the boiler operating instructions For operating in room air independent mode the burn...

Page 30: ...he oil hoses have to be insert in a rubber grommet that is insert into the recess of he base plate The recess of the base plate that is not used is respectively sealed by using a rubber grommet withou...

Page 31: ...has been set on the pressure con troller at the oil pump By turning the setting screw clockwise the oil pressure will conse quently increase and also therefore the in jected oil mass flow In the oppos...

Page 32: ...L 60 KLV 2 S 26 2 19 0 60 80 100x150 24 11 0 6 3 27 4 4 5 2 5 2 5 HL 60 KLV 2 S 27 2 28 0 60 80 100x150 24 11 2 6 5 28 4 4 5 2 5 2 5 HL 60 KLV 2 S 28 2 36 0 60 80 100x150 24 11 5 6 7 29 4 4 5 2 5 2 5...

Page 33: ...Siemens LOA 24 green brown yellow white 31 32 N 3 R Post purge relay TR 120 1 L N S black blue brown 12 11 1 1 2 3 LD brown yellow green blue 4 N 1 2 V blue yellow green brown N 3 31 1 3 2 BM M 1 vio...

Page 34: ...33 EN 7 Expanded view with spare parts list...

Page 35: ...00006 2 Gasket for flange unit N P Unit 10006 00062 3 Burner pipe N P Unit 10005 00078 4 Gasket for burner pipe N P Unit 10006 00058 5 Unitflange angular N P Unit 10002 00121 6 O Ring 99x4 10006 00059...

Page 36: ...et head cap screw SW4 similar DIN 912 M4x18 for cover 10023 00184 Countersunk crosshead screw DIN 965 M3x5 for sealing guide ring 10023 00043 Hexagon socket head cap screw SW 4 DIN 912 M4x14 for holde...

Page 37: ...ary filter Defective oil pump gear Exchange oil pump Discharge of paraffin 4 C Install cold insulation Heating oil no longer free flowing 1 C Install cold insulation 5 Solenoid valve Solenoid valve do...

Page 38: ...2 S KLV 2 S NLV 2 S PLV 2 S Base plate Shift flange HL 60 GLV 2 S ILV 2 S KLV 2 S NLV 2 S PLV 2 S Base plate Unit flange HL 60 GLV 2 S ILV 2 S KLV 2 S NLV 2 S PLV 2 S Mini base plate Unit flange 9 Di...

Page 39: ...8 EN 9 Dimensions of the burner HL 60 GLV 2 S ILV 2 S KLV 2 S Shift flange HL 60 GLV 2 S ILV 2 S KLV 2 S Unit flange HL 60 GLV 2 S ILV 2 S KLV 2 S Shift flange HL 60 GLV 2 S ILV 2 S KLV 2 S Unit flang...

Page 40: ...39 EN HL 60 NLV 2 S PLV 2 S Shift flange HL 60 NLV 2 S PLV 2 S Unit flange HL 60 NLV 2 S PLV 2 S Shift flange HL 60 NLV 2 S PLV 2 S Unit flange 9 Dimensions of the burner...

Page 41: ...ope ration conditions we recommend a post run of the blower after the bur ners deactivation To realize the post run of the blower we offer two different post ventilation systems Oil firing unit Sieme...

Page 42: ...e running period of the burner we offer you the installation of a combination of oil flow me ter and operating hour meter The installation of the oil flow meter and operating hour meter may be carried...

Page 43: ...N 14214 1 6 Composants Composant Fabricant D signation mod le Moteur Hanning O1A095 055 Pompe fioul Danfoss BFP 21 L3 LE R chauffeur fioul Danfoss FPHE LE PTC 50 Unit d allumage Danfoss EBI 4 Beru ZT...

Page 44: ...le combustible l lectrovanne est mise sous tension ce qui provoque son ouverture Le combustible parvient ensuite au gicleur la pression r gl e sur la vanne manor gulatrice Pour r duire les missions po...

Page 45: ...ez la sensibilit ce qu il faut pour que les deux LED s allument Puis il faut faire d marrer nouveau le br leur Ce faisant il faut bien v rifier que la LED 1 ne vacille pas pendant la pr ventilation Po...

Page 46: ...verrouill le voyant de d rangement reste constamment allum en rouge Cet tat demeure aussi en cas de coupure de la tension secteur L automate d allumage lectronique LMO14 dispose en outre d un affi ch...

Page 47: ...la fabrication en s rie le br leur a t pr r gl sur les syst mes bi tubes Lors de la conversion de la pompe au mode Monotube il faut obturer l embout de retour avec un bouchon et retirer la vis de con...

Page 48: ...ment sur le c t gauche ou droit de la plaque de base partir du br leur Pour ce faire les flexibles de fioul sont pos s dans une douille caoutchout e perc e qui elle m me est plac e dans l videment de...

Page 49: ...gl e sur le ma nor gulateur Le fait de tourner la vis de r glage dans le sens horaire hausse la pres sion du fioul et donc le flux massique du fioul inject Inversement le fait de tourner la vis de r...

Page 50: ...1 0 60 80 100x150 24 10 0 5 4 23 4 4 5 2 5 2 5 HL 60 KLV 2 S 26 2 19 0 60 80 100x150 24 11 0 6 3 27 4 4 5 2 5 2 5 HL 60 KLV 2 S 27 2 28 0 60 80 100x150 24 11 2 6 5 28 4 4 5 2 5 2 5 HL 60 KLV 2 S 28 2...

Page 51: ...pour LMO 14 A1 Siemens LOA 24 LMO 14 vert marron jaune blanc 31 32 N 3 R Relais de poursuite de marche TR 120 1 L N S noir bleu marron 12 11 1 1 2 3 marron jaune vert bleu 4 N 1 2 V bleu jaune vert m...

Page 52: ...51 FR 7 Vue clat e avec liste des pi ces de rechange...

Page 53: ...de protection pour du raccord de mesure 10014 00014 54 D tecteur de flamme KLC 2002 avec filtre 10011 00024 54 D tecteur de flamme IRD 1010 10011 00001 55 Gicleur d air D19 G 10015 00006 55 Gicleur d...

Page 54: ...r couvercle du porte gicleur et pompe 10023 00004 Vis autoformeuse DIN 7500 CM3x16 pour fiche Euro 10023 00007 Vis t te cylindrique six pans creux calibre 4 similaire DIN 7984 M8x30 pour bo tier de co...

Page 55: ...filtre encrass Nettoyer changer pr filtre R ducteur pompe fioul d fectueux Changer la pompe Production de paraffine 4 C Poser conduites l abri du froid Fioul de chauffage trop visqueux 1 C Poser condu...

Page 56: ...S NLV 2 S PLV 2 S Plaque de base Bride coulissante HL 60 GLV 2 S ILV 2 S KLV 2 S NLV 2 S PLV 2 S Plaque de base Bride unitaire HL 60 GLV 2 S ILV 2 S KLV 2 S NLV 2 S PLV 2 S Plaque de base mini Bride...

Page 57: ...Dimensions du br leur HL 60 GLV 2 S ILV 2 S KLV 2 S Bride coulissante HL 60 GLV 2 S ILV 2 S KLV 2 S Bride unitaire HL 60 GLV 2 S ILV 2 S KLV 2 S Bride coulissante HL 60 GLV 2 S ILV 2 S KLV 2 S Bride u...

Page 58: ...57 FR 9 Dimensions du br leur HL 60 NLV 2 S PLV 2 S Bride coulissante HL 60 NLV 2 S PLV 2 S Bride unitaire HL 60 NLV 2 S PLV 2 S Bride coulissante HL 60 NLV 2 S PLV 2 S Bride unitaire...

Page 59: ...us recommandons dans ces conditions de mise en uvre que la soufflerie continue de tourner apr s avoir teint le br leur Pour obtenir cette poursuite de marche nous proposons deux syst mes de post venti...

Page 60: ...br leur nous proposons d incorporer un compteur combin Consommation de fioul et Heures de service L incorporation du compteur d heures de service peut avoir lieu en usine ou en utilisant le kit de con...

Page 61: ...i 10 FAME secondo la norma DIN 14214 1 6 Componenti Componente Produttore Modello Motore Hanning O1A095 055 Pompa dell olio combustibile Danfoss BFP 21 L3 LE Preriscaldore dell olio Danfoss FPHE LE PT...

Page 62: ...ombustibile la valvola magnetica viene alimentata e quindi si apre Il combustibile giunge pertanto all ugello con la pressione regolata sulla valvola di regolazione della pressione Per limitare al mas...

Page 63: ...nto occorre controllare che durante la preventilazione il LED 1 non tremoli Per ragioni di sicurezza si consiglia di regolare la sensibilit ad un livello non pi alto del necessario Entrambi i LED sono...

Page 64: ...uzione della tensione di rete L automatismo d accensione elettrico LMO 14 dotato inoltre di un indi catore di funzionamento visivo e di diagnostica della causa del guasto che viene indicata attraverso...

Page 65: ...e il manicotto di recu pero usando il tappo di chiusura e rimuovere la vite di cambio nel condotto di collegamento tra lato pressione e lato aspirazione Per evitare anomalie del bruciatore a causa del...

Page 66: ...na boc cola di gomma perforata che viene inserita nella cavit della piastra di base La cavit non usata viene chiusa con una boccola non perforata boccola di riempimento I tubi della variante dell impi...

Page 67: ...vite di regolazione in senso orario si aumenta la pres sione e quindi anche la portata dell olio combusti bile inietatto E viceversa la pressione viene diminuita girando la vite in senso an tiorario L...

Page 68: ...4 10 0 5 4 23 4 4 5 2 5 2 5 HL 60 KLV 2 S 26 2 19 0 60 80 100x150 24 11 0 6 3 27 4 4 5 2 5 2 5 HL 60 KLV 2 S 27 2 28 0 60 80 100x150 24 11 2 6 5 28 4 4 5 2 5 2 5 HL 60 KLV 2 S 28 2 36 0 60 80 100x150...

Page 69: ...N 6 h 1 2 solo per LMO 14 A1 Siemens LOA 24 LMO 14 verde marrone giallo bianco 31 32 N 3 R Rel di spegnimento TR 120 1 L N S nero blu marrone 12 11 1 1 2 3 marrone giallo verde blu 4 N 1 2 V blu giall...

Page 70: ...69 IT 7 Disegno esploso con lista pezzi di ricambio...

Page 71: ...a pressione 10008 00001 53 Bussola di protezione per nipplo di misurazione della pressione 10014 00014 54 Sonda di fiamma KLC 2002 con filtro 10011 00024 54 Rilevatore di tremolio IRD 10011 00001 55 U...

Page 72: ...e con testa ad esagono incassato SW4 simile a DIN 912 M4x18 per copertura 10023 00184 Vite a testa svasata con intaglio a croce DIN 965 M3x5 per guarnizione ad anello di ritegno 10023 00043 Vite con t...

Page 73: ...to difettoso Sostituire l accoppiamento Il filtro della pompa del combustibile sporco Pulire il filtro della pompa del combustibile Il prefiltro sporco Sostituire pulire il prefiltro Riduttore della p...

Page 74: ...LV 2 S PLV 2 S Piastra di base Flangia scorrevole HL 60 GLV 2 S ILV 2 S KLV 2 S NLV 2 S PLV 2 S Piastra di base Flangia a unit HL 60 GLV 2 S ILV 2 S KLV 2 S NLV 2 S PLV 2 S Piastra di base mini Flangi...

Page 75: ...ensioni del bruciatore HL 60 GLV 2 S ILV 2 S KLV 2 S Flangia scorrevole HL 60 GLV 2 S ILV 2 S KLV 2 S Flangia a unit HL 60 GLV 2 S ILV 2 S KLV 2 S Flangia scorrevole HL 60 GLV 2 S ILV 2 S KLV 2 S Flan...

Page 76: ...75 IT 9 Dimensioni del bruciatore HL 60 NLV 2 S PLV 2 S Flangia scorrevole HL 60 NLV 2 S PLV 2 S Flangia a unit HL 60 NLV 2 S PLV 2 S Flangia scorrevole HL 60 NLV 2 S PLV 2 S Flangia a unit...

Page 77: ...circondano gli impianti di miscelazione a queste condizioni d impiego si consiglia di installare un impianto di ventilazione posteriore che viene attivata dopo lo spegnimento del bruciatore Per quest...

Page 78: ...possibile installare una combinazione di un contatore portata olio e un contaore L installazione pu essere effettuata in fabbrica oppure a mezzo del seguente kit di mo difica codice d ordine 10003 000...

Page 79: ...ture di scarico C Raumlufttemperatur Room air temperature Temp rature air int rieur Temperatura dell aria ambientale C Feuerraumdruck Combustion chamber pressure Pression de feu Pressione camera di co...

Page 80: ...um Date Date Data durch by par per Wartung Service Entretien Manutenzione Datum Date Date Data durch by par per Wartung Service Entretien Manutenzione Datum Date Date Data durch by par per Wartung Ser...

Page 81: ...Herrmann GmbH u Co KG Liststra e 8 D 71336 Waiblingen Tel 49 7151 98928 0 Fax 49 7151 98928 49 info herrmann burners de www herrmann burners de 10029 00053 1 80 2 04550 CUSTOMIZED COMBUSTION CONCEPTS...

Reviews: