18
G
B
3. Open gently the drain valve.
4. Keep the compressor tilted until all moisture has been removed.
5. Close the drain valve.
Warning!
Dispose of the condensation water in an environmentally
compatible manner at the appropriate collection point.
7.3 Safety valve (ref. F)
The safety valve has been set for the highest permitted pressure
of the pressure vessel. It is prohibited to adjust the safety valve.
Actuate the safety valve from time to time to ensure that it works when
required. Pull the ring with sufficient force (fig. 5) until you can hear the
compressed air being released. Then release the ring again.
7.4 Storage
Warning!
Disconnect the plug from the socket, vent the appliance and
tools connected to it and empty the condensate.
Switch off the compressor and make sure that it is secured in
such a way that it cannot be started up again by any unauthorized
person.
Warning!
Store the compressor only in a dry location which is not
accessible to unauthorized persons.
Always store upright, never tilted!
8. DISPOSAL AND RECYCLING
Pursuant to Directive 2012/19/EU on waste electrical
and electronic equipment (WEEE).
The symbol carrying a crossed-out refuse container depicted on any
equipment or the relative packaging means that, at the end of its useful
life, said product must be disposed of separately from other waste.
The user must therefore take said equipment to the centres
specialising in differentiated refuse collection of electric and electronic
equipment or alternatively return it to the reseller when purchasing a
new similar piece of equipment.
Thanks to differentiated refuse collection, discarded equipment can
be sent to be recycled, treated and disposed of in an environmentally-
friendly manner; this helps avoiding possible negative effects on the
environment and on health and promotes the re-employment and/or
recycling of the equipment’s materials.
Any unauthorised disposal of the product by the user will result in the
application of the fines provided for by the regulations in force.
9. TROUBLESHOOTING GUIDE
Note: Remove power source and drain tank pressure prior to making any repairs or adjustments.
Fault
Cause
Remedy
The compressor stops and restarts
automatically after a few minutes.
Tripping of the thermal cutout due to
overheating of the motor.
Clean the air ducts in the conveyor. Ventilate
the work area.
After a few attempts to restart, the
compressor stops.
Tripping of the thermal cutout due to
overheating of the motor (removal of the
plug with the compressor running, low
power voltage).
Activate the on/off switch. Ventilate the work
area. Wait a few minutes. The compressor
will restart independently.
The compressor does not stop and the
safety valve is tripped.
Irregular compressor operation or pressure
switch malfunction.
Remove the plug and contact the Service
Center.
Any other type of operation must be carried out by authorized Service Centers, requesting original parts. Tampering
with the machine may impair its safety and in any case make the warranty null and void.
Warranty and repair.
In the event of defective goods or requirements for spare parts, kindly contact the sales point where you made your purchase.