16
G
B
All users must read and fully understand all information
contained in this owner’s manual before assembling, operating,
or maintaining this air compressor.
Carefully review the following rules for safe operation and fully
understand all warnings.
1. SAFETY RULES
This symbol indicates warnings to be read before using the product so as
to prevent injury to the user.
Compressed air is a potentially dangerous form of energy; always take
great care when using the compressor and its accessories.
Warning: the compressor may restart when power is restored following
a blackout.
An ACOUSTIC PRESSURE value of 4 m. corresponds to the
ACOUSTIC POWER value stated on the label located on the
compressor, minus 20 dB.
THINGS TO DO
●
The compressor must be used in a suitable environment (well
ventilated with an ambient temperature of b5°C and
+40°C) and never in places affected by dust, acids, vapours,
explosive or flammable gases.
●
Always maintain a safety distance of at least 4 meters between the
compressor and the work area.
●
Any coloring of the shroud of the compressor (for models envisaging
this) during painting operations indicates that the distance is too short.
● Insert the plug of the electric cable in a socket of suitable shape,
voltage and frequency complying with current regulations.
●
Use extension cables with a maximum length of 5 meters and of
suitable cross-section.
●
The use of extension cables of different length and also of adapters
and multiple sockets should be avoided.
●
Always use the switch
I/O
to switch off the compressor.
● Always use the handle to move the compressor.
●
Always disconnect power cord and air hose from the air compressor
before transporting.
● When operating, the compressor must be placed on a stable,
horizontal surface.
THINGS
NOT
TO DO
● Never direct the jet of air towards persons, animals or your body.
(Always wear safety goggles to protect your eyes against flying objects
that may be lifted by the jet of air).
● Never direct the jet of liquids sprayed by tools connected to the
compressor towards the compressor.
● Never use the appliance with bare feet or wet hands or feet.
●
Never pull the power cable to disconnect the plug from the socket or
to move the compressor.
● Never leave the appliance exposed to adverse weather conditions.
● Never transport the compressor with the receiver under pressure.
● Do not weld or machine the receiver. In the case of faults or rusting,
replace the entire receiver.
● Never allow inexpert persons to use the compressor. Keep children
and animals at a distance from the work area.
●
This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning the use of the appliance by a person
responsible for their safety.
●
Children should be supervised to ensure that they do not play with
the appliance.
● Do not position flammable or Nylon®/fabric objects closed to and/
or on the compressor.
● Never clean the compressor with flammable liquids or solvents.
Check that you have unplugged the compressor and clean with a
damp cloth only.
● The compressor must be used only for air compression. Do not use
the compressor for any other type of gas.
●
The compressed air produced by the compressor cannot not be used
for pharmaceutical, food or medical purposes except after particular
treatments and cannot be used to fill the air bottles of scuba divers.
● To avoid serious burns, never touch the cylinder head parts or tubing
during or immediately after operation.
● Pay attention to the work being carried out. Use common sense.
Do not stand on the compressor. Do not allow the compressor to
operate unattended.
THINGS YOU SHOULD KNOW
●
To avoid overheating of the electric motor, this compressor is
designed for intermittent operation
(do not operate on more than
a 50% duty cycle. If this air compressor pumps air more than 50%
of one hour, then the compressor’s capability is less than the air
delivery required by the application. Always match the air volume
requirements of the attachment or accessory with the air volume
delivery of the compressor). In the case of overheating, the thermal
cut-out of the motor trips, automatically cutting off the power when
the temperature is too high. The motor restarts automatically when
normal temperature conditions are restored.
● The versions that feature a solenoid valve are equipped with a valve
that allows the air to be vented from the head, in order to facilitate
the next restart of the compressor. Therefore, it is normal to feel
vented air for a few seconds, when the compressor reaches the cut-
off pressure (set by the manufacturer during the testing phase). The
same phenomenon occurs even when the compressor is switched off.
● (For models envisaging this; figure 1c): the compressor is equipped
with a pressure switch equipped with a delayed air discharge valve
which facilitates starting the engine and therefore air will be vented
from it, when the tank is empty, for a few seconds.
●
When the compressor is plugged into an electrical source and
the
I/O
switch is in the “ON” position, this compressor will
cycle automatically.
–
Never touch any moving parts.
–
Keep all body parts, hair, clothing, and jewelry away from moving
parts.
– Never operate the air compressor without all guards and shrouds
in place.
–
Never stand on the compressor.
● The compressor is fitted with a safety valve that is tripped in the case of
malfunctioning of the pressure switch in order to assure machine safety.
●
The red notch on the pressure gauge refers to the maximum operating
pressure of the tank. It does not refer to the adjusted pressure.
● When fitting a tool, the flow of air in output must be switched off.
● When using compressed air, you must know and comply with
the safety precautions to be adopted for each type of application
(inflation, pneumatic tools, painting, washing with water-based
detergents only, etc.).
●
Never exceed the maximum allowable pressure recommended by
the manufacturer of any attachment or accessory you use with this
compressor.
●
Please check that the air consumption and the maximum working
pressure of the pneumatic tool and connection pipes (with the
compressor) to be used, are compatible with the pressure set on
the pressure regulator and with the amount of air supplied by the
compressor.
●
The compressor's performance is guaranteed for operation between
0 and 1000 meters above the sea level.
Preserve this handbook for future reference