Operation Manual
Version 2.0
9
Part Number MAN-000009
Increment Value
Sets the increment that the bin weight will be rounded to. The reading from a bin
is rounded to the nearest multiple of the increment, using standard rounding rules.
The possible values are: 1, 2, 5, 10, 20, 50, 100, 200, 500, 1., 2.,5.,10.,20., and 50..
Example:
If an increment of 10 is selected and the net value of a bin’s weight is
11,314 lbs., the segmented display will read 11310. Refer to Figure 1 for more
examples based on a net weight of 11,314 pounds.
Note:
When the increment value is followed by a
“.”,
the displayed weight
value is then scaled by 10. For example, an increment value of 1. would cause
120462 pounds to show as 12046. on the display. This is required when the
displayed weight will exceed the 5 available digits on the BTB200.
1. Press the BIN key to select the desired bin.
2. Use the UPPER
key to increase the increment value.
3. Use the LOWER
key to decrease the increment value.
Segmented display:
Full Value
Sets the weight of a full bin. This is for calibration of the LED bar graph level. The
value dictates at what net weight the bar graph will display completely full (all 16 LEDs lit).
1. Press the BIN key to select the desired bin.
2. Use the UPPER
key to increase the value by 1 lb.
3. Use the LOWER key to decrease the value by 1 lb.
Segmented display:
Zero Value
Sets the weight of the empty bin. This value can also be set in the Operation Settings. This is used to compensate for
the empty weight of the bin to give an accurate value for the net weight of the material inside the bin.
Example: A bin weighs 1,200 lbs. empty. By setting the zero value to 1200, the BinTrac indicator calculates the
material weight as the total weight less the zero-weight value.
Note:
If the bin was zeroed on the Indicator by pressing and holding the UPPER
and LOWER
– Startup
step 5
), this field will display the automatically calculated amount.
1. Press the BIN key to select the desired bin.
2. Use the UPPER
key to increase the value by 1.
3. Use the LOWER
key to decrease the value by 1.
Segmented display:
incr
Display
1
11314
2
11314
5
11315
10
11310
20
11320
50
11300
100
11300
200
11400
500
11500
1.
1131.
2.
1132.
5.
1130.
10.
1130.
20.
1140.
50.
1150.
Figure 1
Summary of Contents for BinTrac Breeder Control
Page 18: ...Operation Manual Version 2 0 18 Part Number MAN 000009 Wiring Diagram...
Page 25: ...Operation Manual Version 2 0 25 Part Number MAN 000009 Wiring Diagram OPTIONAL...
Page 36: ...Operation Manual Version 2 0 36 Part Number MAN 000009 Wiring Diagram...
Page 47: ...Operation Manual Version 2 0 47 Part Number MAN 000009 Wiring Diagram...