Operation Manual
Version 2.0
32
Part Number MAN-000009
Batch
Enables you to set the batch option to
LoAd
or
u.LoAd
. In this configuration, the parameter MUST
be set for
u.LoAd
for the hen unload batching auger.
Segmented display:
22. Press the SELECT key to enter BATCH menu, and
.
should be displayed (If
is displayed,
press
to set to
.
).
23. Press the SELECT key and then
is shown.
24. Press
and
. .
is displayed.
Capacity (L.C.Cap)
The load cell system capacity is the sum of all the load cells rated capacity in either pounds or kilograms. This
parameter sets the calibration of the system. To determine this value, multiply the number of load cells by their
capacity.
Example: A four leg bin with 5k load cells would require an L.C.CAP setting of 20000 pounds.
Segmented display:
25. Press the SELECT key.
26. The REMOTE display will mirror the value you entered on the MASTER display. Verify that this is the case
and that the L.C.CAP matches what you entered on the MASTER display. Now, press the SELECT key.
End
Allows the user to exit SETUP mode.
27. Press the
key 5 times until
is displayed. Press the SELECT key to exit SETUP mode.
Segmented display:
Summary of Contents for BinTrac Breeder Control
Page 18: ...Operation Manual Version 2 0 18 Part Number MAN 000009 Wiring Diagram...
Page 25: ...Operation Manual Version 2 0 25 Part Number MAN 000009 Wiring Diagram OPTIONAL...
Page 36: ...Operation Manual Version 2 0 36 Part Number MAN 000009 Wiring Diagram...
Page 47: ...Operation Manual Version 2 0 47 Part Number MAN 000009 Wiring Diagram...